Physics-based shape matching for intraoperative image guidance

Purpose: Soft-tissue deformations can severely degrade the validity of preoperative planning data during computer assisted interventions. Intraoperative imaging such as stereo endoscopic, time-of-flight or, laser range scanner data can be used to compensate these movements. In this context, the intr...

Full description

Saved in:
Bibliographic Details
Other Authors: Suwelack, Stefan (Other) , Wagner, Martin (Other) , Vetter, Josephin (Other) , Kenngott, Hannes Götz (Other) , Müller, Beat P. (Other)
Format: Article (Journal)
Language:English
Published: 2014
In: Medical physics
Year: 2014, Volume: 41, Issue: 11, Pages: 111901-1-111901-12
ISSN:2473-4209
DOI:10.1118/1.4896021
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1118/1.4896021
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1118/1.4896021
Get full text
Author Notes: Stefan Suwelack, Sebastian Röhl, Sebastian Bodenstedt, Daniel Reichard, Rüdiger Dillmann, Thiago dos Santos, Lena Maier-Hein, Martin Wagner, Josephine Wünscher, Hannes Kenngott, Beat P. Müller and Stefanie Speidel

MARC

LEADER 00000caa a2200000 c 4500
001 1521551154
003 DE-627
005 20240516112016.0
007 cr uuu---uuuuu
008 151110s2014 xx |||||o 00| ||eng c
024 7 |a 10.1118/1.4896021  |2 doi 
035 |a (DE-627)1521551154 
035 |a (DE-576)45155115X 
035 |a (DE-599)BSZ45155115X 
035 |a (OCoLC)1340717595 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
245 0 0 |a Physics-based shape matching for intraoperative image guidance  |c  Stefan Suwelack, Sebastian Röhl, Sebastian Bodenstedt, Daniel Reichard, Rüdiger Dillmann, Thiago dos Santos, Lena Maier-Hein, Martin Wagner, Josephine Wünscher, Hannes Kenngott, Beat P. Müller and Stefanie Speidel 
264 1 |c 2014 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.05.2024 
500 |a Erscheinungsdatum im PDF: Veröffentlicht: 8. Oktober 2014, Erscheinungsdatum auf der Frontdoor: Erstmals veröffentlicht: 30. November 2016 
520 |a Purpose: Soft-tissue deformations can severely degrade the validity of preoperative planning data during computer assisted interventions. Intraoperative imaging such as stereo endoscopic, time-of-flight or, laser range scanner data can be used to compensate these movements. In this context, the intraoperative surface has to be matched to the preoperative model. The shape matching is especially challenging in the intraoperative setting due to noisy sensor data, only partially visible surfaces, ambiguous shape descriptors, and real-time requirements. Methods: A novel physics-based shape matching (PBSM) approach to register intraoperatively acquired surface meshes to preoperative planning data is proposed. The key idea of the method is to describe the nonrigid registration process as an electrostatic-elastic problem, where an elastic body (preoperative model) that is electrically charged slides into an oppositely charged rigid shape (intraoperative surface). It is shown that the corresponding energy functional can be efficiently solved using the finite element (FE) method. It is also demonstrated how PBSM can be combined with rigid registration schemes for robust nonrigid registration of arbitrarily aligned surfaces. Furthermore, it is shown how the approach can be combined with landmark based methods and outline its application to image guidance in laparoscopic interventions. Results: A profound analysis of the PBSM scheme based on in silico and phantom data is presented. Simulation studies on several liver models show that the approach is robust to the initial rigid registration and to parameter variations. The studies also reveal that the method achieves submillimeter registration accuracy (mean error between 0.32 and 0.46 mm). An unoptimized, single core implementation of the approach achieves near real-time performance (2 TPS, 7-19 s total registration time). It outperforms established methods in terms of speed and accuracy. Furthermore, it is shown that the method is able to accurately match partial surfaces. Finally, a phantom experiment demonstrates how the method can be combined with stereo endoscopic imaging to provide nonrigid registration during laparoscopic interventions. Conclusions: The PBSM approach for surface matching is fast, robust, and accurate. As the technique is based on a preoperative volumetric FE model, it naturally recovers the position of volumetric structures (e.g., tumors and vessels). It cannot only be used to recover soft-tissue deformations from intraoperative surface models but can also be combined with landmark data from volumetric imaging. In addition to applications in laparoscopic surgery, the method might prove useful in other areas that require soft-tissue registration from sparse intraoperative sensor data (e.g., radiation therapy). 
700 1 |a Suwelack, Stefan  |0 (DE-588)1017027110  |0 (DE-627)690272774  |0 (DE-576)350249865  |4 oth 
700 1 |a Wagner, Martin  |d 1988-  |0 (DE-588)1060231980  |0 (DE-627)799324337  |0 (DE-576)416324282  |4 oth 
700 1 |a Vetter, Josephin  |d 1988-  |0 (DE-588)1078510334  |0 (DE-627)838986390  |0 (DE-576)45155647X  |4 oth 
700 1 |a Kenngott, Hannes Götz  |d 1979-  |0 (DE-588)141469994  |0 (DE-627)62780117X  |0 (DE-576)324023065  |4 oth 
700 1 |a Müller, Beat P.  |d 1971-  |0 (DE-588)14066209X  |0 (DE-627)70374819X  |0 (DE-576)317992287  |4 oth 
773 0 8 |i Enthalten in  |t Medical physics  |d Hoboken, NJ : Wiley, 1974  |g 41(2014), 11 vom: Nov., Artikel-ID 111901, Seite 111901-1-111901-12  |h Online-Ressource  |w (DE-627)265784867  |w (DE-600)1466421-5  |w (DE-576)074891243  |x 2473-4209  |7 nnas  |a Physics-based shape matching for intraoperative image guidance 
773 1 8 |g volume:41  |g year:2014  |g number:11  |g month:11  |g elocationid:111901  |g pages:111901-1-111901-12  |g extent:12  |a Physics-based shape matching for intraoperative image guidance 
856 4 0 |u https://doi.org/10.1118/1.4896021  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1118/1.4896021  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20151110 
993 |a Article 
994 |a 2014 
998 |g 14066209X  |a Müller, Beat P.  |m 14066209X:Müller, Beat P.  |d 910000  |d 910200  |e 910000PM14066209X  |e 910200PM14066209X  |k 0/910000/  |k 1/910000/910200/  |p 11 
998 |g 141469994  |a Kenngott, Hannes Götz  |m 141469994:Kenngott, Hannes Götz  |d 910000  |d 910200  |e 910000PK141469994  |e 910200PK141469994  |k 0/910000/  |k 1/910000/910200/  |p 10 
998 |g 1078510334  |a Vetter, Josephin  |m 1078510334:Vetter, Josephin  |d 910000  |d 910200  |e 910000PV1078510334  |e 910200PV1078510334  |k 0/910000/  |k 1/910000/910200/  |p 9 
998 |g 1060231980  |a Wagner, Martin  |m 1060231980:Wagner, Martin  |d 910000  |d 910200  |e 910000PW1060231980  |e 910200PW1060231980  |k 0/910000/  |k 1/910000/910200/  |p 8 
999 |a KXP-PPN1521551154  |e 287174999X 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Physics-based shape matching for intraoperative image guidance","title_sort":"Physics-based shape matching for intraoperative image guidance"}],"language":["eng"],"person":[{"family":"Suwelack","given":"Stefan","role":"oth","display":"Suwelack, Stefan"},{"family":"Wagner","role":"oth","given":"Martin","display":"Wagner, Martin"},{"family":"Vetter","role":"oth","given":"Josephin","display":"Vetter, Josephin"},{"family":"Kenngott","role":"oth","given":"Hannes Götz","display":"Kenngott, Hannes Götz"},{"family":"Müller","given":"Beat P.","role":"oth","display":"Müller, Beat P."}],"name":{"displayForm":[" Stefan Suwelack, Sebastian Röhl, Sebastian Bodenstedt, Daniel Reichard, Rüdiger Dillmann, Thiago dos Santos, Lena Maier-Hein, Martin Wagner, Josephine Wünscher, Hannes Kenngott, Beat P. Müller and Stefanie Speidel"]},"id":{"eki":["1521551154"],"doi":["10.1118/1.4896021"]},"physDesc":[{"extent":"12 S."}],"relHost":[{"pubHistory":["1.1974 -"],"part":{"pages":"111901-1-111901-12","extent":"12","issue":"11","text":"41(2014), 11 vom: Nov., Artikel-ID 111901, Seite 111901-1-111901-12","year":"2014","volume":"41"},"language":["eng"],"title":[{"title":"Medical physics","title_sort":"Medical physics"}],"recId":"265784867","origin":[{"publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]","dateIssuedDisp":"1974-","dateIssuedKey":"1974","publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY"}],"titleAlt":[{"title":"Medical physics online"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 01.08.2025"],"physDesc":[{"extent":"Online-Ressource"}],"disp":"Physics-based shape matching for intraoperative image guidanceMedical physics","id":{"issn":["2473-4209","1522-8541"],"zdb":["1466421-5"],"eki":["265784867"]},"name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]}}],"note":["Gesehen am 16.05.2024","Erscheinungsdatum im PDF: Veröffentlicht: 8. Oktober 2014, Erscheinungsdatum auf der Frontdoor: Erstmals veröffentlicht: 30. November 2016"],"origin":[{"dateIssuedDisp":"2014","dateIssuedKey":"2014"}],"recId":"1521551154","type":{"media":"Online-Ressource","bibl":"article-journal"}} 
SRT |a PHYSICSBAS2014