Time-resolved optically stimulated luminescence of Al 2 O 3: C for ion beam therapy dosimetry

The objective of this study was to characterize the time-resolved (TR) optically stimulated luminescence (OSL) from Al 2 O 3 :C detectors and investigate methodologies to improve the accuracy of these detectors in ion beam therapy dosimetry, addressing the reduction in relative response to high line...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Yukihara, Eduardo G. (VerfasserIn) , Brons, Stephan (VerfasserIn) , Tessonnier, Thomas (VerfasserIn) , Jäkel, Oliver (VerfasserIn) , Greilich, Steffen (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 13 August 2015
In: Physics in medicine and biology
Year: 2015, Jahrgang: 60, Heft: 17, Pages: 6613-6638
ISSN:1361-6560
DOI:10.1088/0031-9155/60/17/6613
Online-Zugang:Verlag, Volltext: http://stacks.iop.org/0031-9155/60/i=17/a=6613
Verlag, Volltext: http://dx.doi.org/10.1088/0031-9155/60/17/6613
Volltext
Verfasserangaben:Eduardo G. Yukihara, Brandon A. Doull, Md Ahmed, Stephan Brons, Thomas Tessonnier, Oliver Jäkel, Steffen Greilich

MARC

LEADER 00000caa a2200000 c 4500
001 1551061988
003 DE-627
005 20230426141159.0
007 cr uuu---uuuuu
008 161216s2015 xx |||||o 00| ||eng c
024 7 |a 10.1088/0031-9155/60/17/6613  |2 doi 
035 |a (DE-627)1551061988 
035 |a (DE-576)481061983 
035 |a (DE-599)BSZ481061983 
035 |a (OCoLC)1340945629 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Yukihara, Eduardo G.  |e VerfasserIn  |0 (DE-588)1121826873  |0 (DE-627)874975727  |0 (DE-576)481025782  |4 aut 
245 1 0 |a Time-resolved optically stimulated luminescence of Al 2 O 3  |b C for ion beam therapy dosimetry  |c Eduardo G. Yukihara, Brandon A. Doull, Md Ahmed, Stephan Brons, Thomas Tessonnier, Oliver Jäkel, Steffen Greilich 
264 1 |c 13 August 2015 
300 |a 26 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.12.2016 
520 |a The objective of this study was to characterize the time-resolved (TR) optically stimulated luminescence (OSL) from Al 2 O 3 :C detectors and investigate methodologies to improve the accuracy of these detectors in ion beam therapy dosimetry, addressing the reduction in relative response to high linear energy transfer (LET) particles common to solid-state detectors. Al 2 O 3 :C OSL detectors (OSLDs) were exposed to proton, 4 He, 12 C and 16 O beams in 22 particle/energy combinations and read using a custom-built TR-OSL reader. The OSL response ##IMG## [http://ej.iop.org/images/0031-9155/60/17/6613/pmb518111ieqn001.gif] $r_\textOSL$ , relative to 60 Co gamma dose to water, and the ratio between the UV and blue OSL emission bands of Al 2 O 3 :C (UV/blue ratio) were determined as a function of the LET. Monte-Carlo simulations with the multi-purpose interaction and transport code FLUKA were used to estimate the absorbed doses and particle energy spectra in the different irradiation conditions. The OSL responses ##IMG## [http://ej.iop.org/images/0031-9155/60/17/6613/pmb518111ieqn002.gif] $r_\textOSL$ varied from 0.980 (0.73 keV μ m −1 ) to 0.288 (120.8 keV μ m −1 ). The OSL UV/blue ratio varied by a factor of two in the investigated LET range, but the variation for 12 C beams was only 11%. OSLDs were also irradiated at different depths of carbon ion spread-out Bragg peaks (SOBPs), where it was shown that doses could be obtained with an accuracy of ±2.0% at the entrance channel and within the SOBP using correction factors calculated based on the OSL responses obtained in this study. The UV/blue ratio did not allow accurate estimation of the dose-averaged LET for 12 C SOBPs, although the values obtained can be explained with the data obtained in this study and the additional information provided by the Monte-Carlo simulations. The results demonstrate that accurate OSLD dosimetry can be performed in ion beam therapy using appropriate corrections for the OSL response. 
700 1 |a Brons, Stephan  |e VerfasserIn  |0 (DE-588)1072782375  |0 (DE-627)828233594  |0 (DE-576)434240478  |4 aut 
700 1 |a Tessonnier, Thomas  |e VerfasserIn  |0 (DE-588)1075079195  |0 (DE-627)83292685X  |0 (DE-576)443252270  |4 aut 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
700 1 |a Greilich, Steffen  |e VerfasserIn  |0 (DE-588)1037178068  |0 (DE-627)752390988  |0 (DE-576)181191989  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 60(2015), 17, Seite 6613-6638  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Time-resolved optically stimulated luminescence of Al 2 O 3 C for ion beam therapy dosimetry 
773 1 8 |g volume:60  |g year:2015  |g number:17  |g pages:6613-6638  |g extent:26  |a Time-resolved optically stimulated luminescence of Al 2 O 3 C for ion beam therapy dosimetry 
856 4 0 |u http://stacks.iop.org/0031-9155/60/i=17/a=6613  |x Verlag  |3 Volltext 
856 4 0 |u http://dx.doi.org/10.1088/0031-9155/60/17/6613  |x Verlag  |x Resolving-System  |3 Volltext 
951 |a AR 
992 |a 20161216 
993 |a Article 
994 |a 2015 
998 |g 1037178068  |a Greilich, Steffen  |m 1037178068:Greilich, Steffen  |p 7  |y j 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 910000  |d 911400  |e 910000PJ1050056302  |e 911400PJ1050056302  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 1075079195  |a Tessonnier, Thomas  |m 1075079195:Tessonnier, Thomas  |d 910000  |d 911400  |e 910000PT1075079195  |e 911400PT1075079195  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 1072782375  |a Brons, Stephan  |m 1072782375:Brons, Stephan  |d 910000  |d 950000  |d 950400  |e 910000PB1072782375  |e 950000PB1072782375  |e 950400PB1072782375  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 4 
999 |a KXP-PPN1551061988  |e 294914716X 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1088/0031-9155/60/17/6613"],"eki":["1551061988"]},"name":{"displayForm":["Eduardo G. Yukihara, Brandon A. Doull, Md Ahmed, Stephan Brons, Thomas Tessonnier, Oliver Jäkel, Steffen Greilich"]},"physDesc":[{"extent":"26 S."}],"recId":"1551061988","language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 16.12.2016"],"title":[{"subtitle":"C for ion beam therapy dosimetry","title":"Time-resolved optically stimulated luminescence of Al 2 O 3","title_sort":"Time-resolved optically stimulated luminescence of Al 2 O 3"}],"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"13 August 2015"}],"person":[{"family":"Yukihara","role":"aut","given":"Eduardo G.","display":"Yukihara, Eduardo G."},{"display":"Brons, Stephan","family":"Brons","role":"aut","given":"Stephan"},{"family":"Tessonnier","role":"aut","given":"Thomas","display":"Tessonnier, Thomas"},{"role":"aut","given":"Oliver","family":"Jäkel","display":"Jäkel, Oliver"},{"display":"Greilich, Steffen","family":"Greilich","role":"aut","given":"Steffen"}],"relHost":[{"recId":"269016163","physDesc":[{"extent":"Online-Ressource"}],"disp":"Time-resolved optically stimulated luminescence of Al 2 O 3 C for ion beam therapy dosimetryPhysics in medicine and biology","pubHistory":["1.1956 -"],"origin":[{"dateIssuedDisp":"1956-","dateIssuedKey":"1956","publisherPlace":"Bristol","publisher":"IOP Publ."}],"part":{"year":"2015","volume":"60","pages":"6613-6638","text":"60(2015), 17, Seite 6613-6638","extent":"26","issue":"17"},"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology","title_sort":"Physics in medicine and biology"}],"id":{"zdb":["1473501-5"],"issn":["1361-6560"],"eki":["269016163"]},"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"]}]} 
SRT |a YUKIHARAEDTIMERESOLV1320