Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty
Purpose: To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. Materials and Methods: In this prospective randomized study 278 radiographs of the knee in follow-up...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
August 2015
|
| In: |
RöFo
Year: 2015, Jahrgang: 187, Heft: 8, Pages: 685-690 |
| ISSN: | 1438-9010 |
| DOI: | 10.1055/s-0034-1399559 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1055/s-0034-1399559 Verlag, Volltext: https://www.thieme-connect.com/products/ejournals/html/10.1055/s-0034-1399559 |
| Verfasserangaben: | J.K. Kloth, M. Tanner, W. Stiller, I. Burkholder, H.U. Kauczor, V. Ewerbeck, M.A. Weber |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 155353896X | ||
| 003 | DE-627 | ||
| 005 | 20220813132641.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 170216s2015 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1055/s-0034-1399559 |2 doi | |
| 035 | |a (DE-627)155353896X | ||
| 035 | |a (DE-576)483538965 | ||
| 035 | |a (DE-599)BSZ483538965 | ||
| 035 | |a (OCoLC)1340960251 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Kloth, Jost |d 1980- |e VerfasserIn |0 (DE-588)139794409 |0 (DE-627)70346602X |0 (DE-576)312722397 |4 aut | |
| 245 | 1 | 0 | |a Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty |c J.K. Kloth, M. Tanner, W. Stiller, I. Burkholder, H.U. Kauczor, V. Ewerbeck, M.A. Weber |
| 264 | 1 | |c August 2015 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 16.02.2017 | ||
| 520 | |a Purpose: To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. Materials and Methods: In this prospective randomized study 278 radiographs of the knee in follow-up of total-knee arthroplasty were performed with standard and 37% reduced radiation dose. The evaluation of the plain-radiographs was conducted using the following criteria: bone-implant interface, implant-surface character, implant-implant discrimination and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score ≥3 or more than 2 criteria with ≥2 points, the radiograph was score das „not assessable“. The study was designed as non-inferiority-trial. Results: 100% of examined radiographs were scored as assessable, hence no statistical inferiority between the examinations with standard and reduced dose could be observed. Singular assessment of the defined criteria was likewise dose-independent. Conclusion: Plain-radiography of the knee following total-knee arthroplasty can be performed with 63% of standard dose without loss of diagnostic validity. Key points: • Due to the non-inferiority of digital radiographs of the knee joint after total-knee arthroplasty done with 37% reduced image receiver dose we recommend the tested speed class of SC 800 as a new reference value for digital radiographs with this indication. Citation Format: • Kloth JK, Tanner M, Stiller W etal. Radiation Dose Reduction in Digital Plain Radiography of the Knee after Total Knee Arthroplasty. Fortschr Röntgenstr 2015; 187: 685-690 | ||
| 700 | 1 | |a Tanner, Michael Christopher |d 1970- |e VerfasserIn |0 (DE-588)133156451 |0 (DE-627)537987355 |0 (DE-576)299659941 |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Ewerbeck, Volker |d 1950- |e VerfasserIn |0 (DE-588)172066190 |0 (DE-627)696972069 |0 (DE-576)132940264 |4 aut | |
| 700 | 1 | |a Weber, Marc-André |d 1973- |e VerfasserIn |0 (DE-588)142373044 |0 (DE-627)704211432 |0 (DE-576)330376802 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t RöFo |d Stuttgart [u.a.] : Thieme, 1975 |g 187(2015), 8, Seite 685-690 |h Online-Ressource |w (DE-627)324825021 |w (DE-600)2031079-1 |w (DE-576)107736748 |x 1438-9010 |7 nnas |a Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty |
| 773 | 1 | 8 | |g volume:187 |g year:2015 |g number:8 |g pages:685-690 |g extent:6 |a Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1055/s-0034-1399559 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://www.thieme-connect.com/products/ejournals/html/10.1055/s-0034-1399559 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20170216 | ||
| 993 | |a Article | ||
| 994 | |a 2015 | ||
| 998 | |g 142373044 |a Weber, Marc-André |m 142373044:Weber, Marc-André |d 910000 |d 911400 |e 910000PW142373044 |e 911400PW142373044 |k 0/910000/ |k 1/910000/911400/ |p 7 |y j | ||
| 998 | |g 172066190 |a Ewerbeck, Volker |m 172066190:Ewerbeck, Volker |d 910000 |d 911460 |e 910000PE172066190 |e 911460PE172066190 |k 0/910000/ |k 1/910000/911460/ |p 6 | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 5 | ||
| 998 | |g 133156451 |a Tanner, Michael Christopher |m 133156451:Tanner, Michael Christopher |d 910000 |d 910200 |e 910000PT133156451 |e 910200PT133156451 |k 0/910000/ |k 1/910000/910200/ |p 2 | ||
| 998 | |g 139794409 |a Kloth, Jost |m 139794409:Kloth, Jost |d 910000 |d 911400 |e 910000PK139794409 |e 911400PK139794409 |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN155353896X |e 2954215704 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"doi":["10.1055/s-0034-1399559"],"eki":["155353896X"]},"name":{"displayForm":["J.K. Kloth, M. Tanner, W. Stiller, I. Burkholder, H.U. Kauczor, V. Ewerbeck, M.A. Weber"]},"physDesc":[{"extent":"6 S."}],"recId":"155353896X","type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 16.02.2017"],"title":[{"title_sort":"Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty","title":"Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty"}],"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"August 2015"}],"person":[{"role":"aut","given":"Jost","family":"Kloth","display":"Kloth, Jost"},{"display":"Tanner, Michael Christopher","family":"Tanner","given":"Michael Christopher","role":"aut"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","role":"aut","given":"Hans-Ulrich"},{"role":"aut","given":"Volker","family":"Ewerbeck","display":"Ewerbeck, Volker"},{"family":"Weber","given":"Marc-André","role":"aut","display":"Weber, Marc-André"}],"relHost":[{"origin":[{"publisher":"Thieme","dateIssuedKey":"1975","dateIssuedDisp":"1975-","publisherPlace":"Stuttgart [u.a.]"}],"language":["ger"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 20.03.2023"],"title":[{"title_sort":"RöFo","title":"RöFo","subtitle":"Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren"}],"physDesc":[{"extent":"Online-Ressource"}],"recId":"324825021","disp":"Radiation dose reduction in digital plain radiography of the knee after total knee arthroplastyRöFo","titleAlt":[{"title":"RöFo vereinigt mit Aktuelle Radiologie"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der neuen bildgebenden Verfahren"}],"pubHistory":["122.1975 -"],"id":{"issn":["1438-9010"],"eki":["324825021"],"doi":["10.1055/s-00000066"],"zdb":["2031079-1"]},"part":{"year":"2015","volume":"187","pages":"685-690","issue":"8","extent":"6","text":"187(2015), 8, Seite 685-690"}}]} | ||
| SRT | |a KLOTHJOSTTRADIATIOND2015 | ||