Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty

Purpose: To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. Materials and Methods: In this prospective randomized study 278 radiographs of the knee in follow-up...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kloth, Jost (VerfasserIn) , Tanner, Michael Christopher (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Ewerbeck, Volker (VerfasserIn) , Weber, Marc-André (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 2015
In: RöFo
Year: 2015, Jahrgang: 187, Heft: 8, Pages: 685-690
ISSN:1438-9010
DOI:10.1055/s-0034-1399559
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1055/s-0034-1399559
Verlag, Volltext: https://www.thieme-connect.com/products/ejournals/html/10.1055/s-0034-1399559
Volltext
Verfasserangaben:J.K. Kloth, M. Tanner, W. Stiller, I. Burkholder, H.U. Kauczor, V. Ewerbeck, M.A. Weber

MARC

LEADER 00000caa a2200000 c 4500
001 155353896X
003 DE-627
005 20220813132641.0
007 cr uuu---uuuuu
008 170216s2015 xx |||||o 00| ||eng c
024 7 |a 10.1055/s-0034-1399559  |2 doi 
035 |a (DE-627)155353896X 
035 |a (DE-576)483538965 
035 |a (DE-599)BSZ483538965 
035 |a (OCoLC)1340960251 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kloth, Jost  |d 1980-  |e VerfasserIn  |0 (DE-588)139794409  |0 (DE-627)70346602X  |0 (DE-576)312722397  |4 aut 
245 1 0 |a Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty  |c J.K. Kloth, M. Tanner, W. Stiller, I. Burkholder, H.U. Kauczor, V. Ewerbeck, M.A. Weber 
264 1 |c August 2015 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.02.2017 
520 |a Purpose: To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. Materials and Methods: In this prospective randomized study 278 radiographs of the knee in follow-up of total-knee arthroplasty were performed with standard and 37% reduced radiation dose. The evaluation of the plain-radiographs was conducted using the following criteria: bone-implant interface, implant-surface character, implant-implant discrimination and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score ≥3 or more than 2 criteria with ≥2 points, the radiograph was score das „not assessable“. The study was designed as non-inferiority-trial. Results: 100% of examined radiographs were scored as assessable, hence no statistical inferiority between the examinations with standard and reduced dose could be observed. Singular assessment of the defined criteria was likewise dose-independent. Conclusion: Plain-radiography of the knee following total-knee arthroplasty can be performed with 63% of standard dose without loss of diagnostic validity. Key points: • Due to the non-inferiority of digital radiographs of the knee joint after total-knee arthroplasty done with 37% reduced image receiver dose we recommend the tested speed class of SC 800 as a new reference value for digital radiographs with this indication. Citation Format: • Kloth JK, Tanner M, Stiller W etal. Radiation Dose Reduction in Digital Plain Radiography of the Knee after Total Knee Arthroplasty. Fortschr Röntgenstr 2015; 187: 685-690 
700 1 |a Tanner, Michael Christopher  |d 1970-  |e VerfasserIn  |0 (DE-588)133156451  |0 (DE-627)537987355  |0 (DE-576)299659941  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Ewerbeck, Volker  |d 1950-  |e VerfasserIn  |0 (DE-588)172066190  |0 (DE-627)696972069  |0 (DE-576)132940264  |4 aut 
700 1 |a Weber, Marc-André  |d 1973-  |e VerfasserIn  |0 (DE-588)142373044  |0 (DE-627)704211432  |0 (DE-576)330376802  |4 aut 
773 0 8 |i Enthalten in  |t RöFo  |d Stuttgart [u.a.] : Thieme, 1975  |g 187(2015), 8, Seite 685-690  |h Online-Ressource  |w (DE-627)324825021  |w (DE-600)2031079-1  |w (DE-576)107736748  |x 1438-9010  |7 nnas  |a Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty 
773 1 8 |g volume:187  |g year:2015  |g number:8  |g pages:685-690  |g extent:6  |a Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty 
856 4 0 |u http://dx.doi.org/10.1055/s-0034-1399559  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://www.thieme-connect.com/products/ejournals/html/10.1055/s-0034-1399559  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20170216 
993 |a Article 
994 |a 2015 
998 |g 142373044  |a Weber, Marc-André  |m 142373044:Weber, Marc-André  |d 910000  |d 911400  |e 910000PW142373044  |e 911400PW142373044  |k 0/910000/  |k 1/910000/911400/  |p 7  |y j 
998 |g 172066190  |a Ewerbeck, Volker  |m 172066190:Ewerbeck, Volker  |d 910000  |d 911460  |e 910000PE172066190  |e 911460PE172066190  |k 0/910000/  |k 1/910000/911460/  |p 6 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 133156451  |a Tanner, Michael Christopher  |m 133156451:Tanner, Michael Christopher  |d 910000  |d 910200  |e 910000PT133156451  |e 910200PT133156451  |k 0/910000/  |k 1/910000/910200/  |p 2 
998 |g 139794409  |a Kloth, Jost  |m 139794409:Kloth, Jost  |d 910000  |d 911400  |e 910000PK139794409  |e 911400PK139794409  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN155353896X  |e 2954215704 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1055/s-0034-1399559"],"eki":["155353896X"]},"name":{"displayForm":["J.K. Kloth, M. Tanner, W. Stiller, I. Burkholder, H.U. Kauczor, V. Ewerbeck, M.A. Weber"]},"physDesc":[{"extent":"6 S."}],"recId":"155353896X","type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 16.02.2017"],"title":[{"title_sort":"Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty","title":"Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty"}],"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"August 2015"}],"person":[{"role":"aut","given":"Jost","family":"Kloth","display":"Kloth, Jost"},{"display":"Tanner, Michael Christopher","family":"Tanner","given":"Michael Christopher","role":"aut"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","role":"aut","given":"Hans-Ulrich"},{"role":"aut","given":"Volker","family":"Ewerbeck","display":"Ewerbeck, Volker"},{"family":"Weber","given":"Marc-André","role":"aut","display":"Weber, Marc-André"}],"relHost":[{"origin":[{"publisher":"Thieme","dateIssuedKey":"1975","dateIssuedDisp":"1975-","publisherPlace":"Stuttgart [u.a.]"}],"language":["ger"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 20.03.2023"],"title":[{"title_sort":"RöFo","title":"RöFo","subtitle":"Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren"}],"physDesc":[{"extent":"Online-Ressource"}],"recId":"324825021","disp":"Radiation dose reduction in digital plain radiography of the knee after total knee arthroplastyRöFo","titleAlt":[{"title":"RöFo vereinigt mit Aktuelle Radiologie"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der neuen bildgebenden Verfahren"}],"pubHistory":["122.1975 -"],"id":{"issn":["1438-9010"],"eki":["324825021"],"doi":["10.1055/s-00000066"],"zdb":["2031079-1"]},"part":{"year":"2015","volume":"187","pages":"685-690","issue":"8","extent":"6","text":"187(2015), 8, Seite 685-690"}}]} 
SRT |a KLOTHJOSTTRADIATIOND2015