Multicenter nellix endovascular aneurysm sealing system experience in aneurysm sac sealing

Objective Despite improvements in endograft devices, operator technique, and patient selection, endovascular repair has not achieved the long-term durability of open surgical aneurysm repair. Persistent or recurrent aneurysm sac flow from failed proximal sealing, component failure, or branch vessel...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Böckler, Dittmar (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 2015
In: Journal of vascular surgery
Year: 2015, Jahrgang: 62, Heft: 2, Pages: 290-298
ISSN:1097-6809
DOI:10.1016/j.jvs.2015.03.031
Online-Zugang:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1016/j.jvs.2015.03.031
Verlag, kostenfrei, Volltext: http://www.sciencedirect.com/science/article/pii/S074152141500381X
Volltext
Verfasserangaben:Dittmar Böckler, Andrew Holden, Matt Thompson, Paul Hayes, Dainis Krievins, Jean-Paul P.M. de Vries, Michel M.P.J. Reijnen

MARC

LEADER 00000caa a2200000 c 4500
001 1553682165
003 DE-627
005 20240315105840.0
007 cr uuu---uuuuu
008 170221s2015 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jvs.2015.03.031  |2 doi 
035 |a (DE-627)1553682165 
035 |a (DE-576)483682160 
035 |a (DE-599)BSZ483682160 
035 |a (OCoLC)1340960484 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Böckler, Dittmar  |d 1966-  |e VerfasserIn  |0 (DE-588)1032367881  |0 (DE-627)738382868  |0 (DE-576)173503969  |4 aut 
245 1 0 |a Multicenter nellix endovascular aneurysm sealing system experience in aneurysm sac sealing  |c Dittmar Böckler, Andrew Holden, Matt Thompson, Paul Hayes, Dainis Krievins, Jean-Paul P.M. de Vries, Michel M.P.J. Reijnen 
264 1 |c August 2015 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 21.02.2017 
520 |a Objective Despite improvements in endograft devices, operator technique, and patient selection, endovascular repair has not achieved the long-term durability of open surgical aneurysm repair. Persistent or recurrent aneurysm sac flow from failed proximal sealing, component failure, or branch vessel flow underpins a significant rate of reintervention after endovascular repair. The Nellix device (Endologix, Irvine, Calif) employs a unique design with deployment of polymer-filled EndoBags surrounding the endograft flow lumens, sealing the aneurysm sac space and potentially reducing complications from persistent sac flow. This retrospective analysis represents the initial experience in consecutive patients treated with the device in real-world practice. Methods This study was performed at six clinical centers in Europe and one in New Zealand during the initial period after commercialization of the Nellix device. Patients underwent evaluation with computed tomography and other imaging modalities following local standards of care. Patients were selected for treatment with Nellix and treated by each institution according to its endovascular repair protocol. Clinical and imaging end points included technical success (successful device deployment and absence of any endoleak at completion angiography), freedom from all-cause and aneurysm-related mortality, endoleak by type, limb occlusion, aneurysm rupture, and reintervention. Results During a 17-month period, 171 patients with abdominal aortic aneurysms were treated with the Nellix device and observed for a median of 5 months (range, 0-14 months). The 153 male and 18 female patients with mean age of 74 ± 7 years had aneurysms 61 ± 9 mm in diameter with an average infrarenal neck length of 28 ± 15 mm and infrarenal angulation of 37 ± 22 degrees. Technical success was achieved in all but two patients (99%); one patient had a type Ib endoleak and another had a type II endoleak. Through the last available follow-up, type Ia endoleak was observed in five patients (3%), type Ib endoleak in four patients (2%), and type II endoleak in four patients (2%). There were eight limb occlusions (5%), among which seven were evident at the 1-month follow-up visit. Aneurysm-related reinterventions were performed in 15 patients (9%). There were no aneurysm ruptures or open surgical conversions. Conclusions this first multicenter postmarket report of the Nellix device for infrarenal abdominal aortic aneurysm repair demonstrates satisfactory results during the initial learning phase of this new technology. The rate of aneurysm exclusion was high, and frequency of complications was low. More definitive conclusions on the value of this novel device await the results of the ongoing Nellix EVAS FORWARD Global Registry and the EVAS FORWARD investigational device exemption trial. 
773 0 8 |i Enthalten in  |t Journal of vascular surgery  |d Amsterdam [u.a.] : Elsevier, 1984  |g 62(2015), 2, Seite 290-298  |h Online-Ressource  |w (DE-627)302720146  |w (DE-600)1492043-8  |w (DE-576)088704807  |x 1097-6809  |7 nnas  |a Multicenter nellix endovascular aneurysm sealing system experience in aneurysm sac sealing 
773 1 8 |g volume:62  |g year:2015  |g number:2  |g pages:290-298  |g extent:9  |a Multicenter nellix endovascular aneurysm sealing system experience in aneurysm sac sealing 
856 4 0 |u http://dx.doi.org/10.1016/j.jvs.2015.03.031  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S074152141500381X  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20170221 
993 |a Article 
994 |a 2015 
998 |g 1032367881  |a Böckler, Dittmar  |m 1032367881:Böckler, Dittmar  |d 910000  |d 910200  |e 910000PB1032367881  |e 910200PB1032367881  |k 0/910000/  |k 1/910000/910200/  |p 1  |x j 
999 |a KXP-PPN1553682165  |e 295450904X 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"title":[{"title_sort":"Journal of vascular surgery","title":"Journal of vascular surgery"}],"id":{"issn":["1097-6809"],"eki":["302720146"],"zdb":["1492043-8"]},"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedKey":"1984","publisherPlace":"Amsterdam [u.a.] ; St. Louis, Mo.","publisher":"Elsevier ; Mosby","dateIssuedDisp":"1984-"}],"recId":"302720146","disp":"Multicenter nellix endovascular aneurysm sealing system experience in aneurysm sac sealingJournal of vascular surgery","type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"JVS"},{"title":"Vascular surgery"}],"language":["eng"],"part":{"year":"2015","volume":"62","pages":"290-298","extent":"9","issue":"2","text":"62(2015), 2, Seite 290-298"},"note":["Gesehen am 15.01.20"],"pubHistory":["1.1984 -"]}],"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"August 2015"}],"title":[{"title_sort":"Multicenter nellix endovascular aneurysm sealing system experience in aneurysm sac sealing","title":"Multicenter nellix endovascular aneurysm sealing system experience in aneurysm sac sealing"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1553682165"],"doi":["10.1016/j.jvs.2015.03.031"]},"physDesc":[{"extent":"9 S."}],"person":[{"family":"Böckler","role":"aut","display":"Böckler, Dittmar","given":"Dittmar"}],"recId":"1553682165","note":["Gesehen am 21.02.2017"],"language":["eng"],"name":{"displayForm":["Dittmar Böckler, Andrew Holden, Matt Thompson, Paul Hayes, Dainis Krievins, Jean-Paul P.M. de Vries, Michel M.P.J. Reijnen"]}} 
SRT |a BOECKLERDIMULTICENTE2015