Wear testing of total hip replacements under severe conditions

Controlled wear testing of total hip replacements in hip joint simulators is a well-established and powerful method, giving an extensive prediction of the long-term clinical performance. To understand the wear behavior of a bearing and its limits under in vivo conditions, testing scenarios should be...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Zietz, Carmen (VerfasserIn) , Reinders, Jörn (VerfasserIn) , Kretzer, Jan Philippe (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: July 2015
In: Expert review of medical devices
Year: 2015, Jahrgang: 12, Heft: 4, Pages: 393-410
ISSN:1745-2422
DOI:10.1586/17434440.2015.1050378
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1586/17434440.2015.1050378
Volltext
Verfasserangaben:Carmen Zietz, Christian Fabry, Joern Reinders, Rebecca Dammer, Jan Philippe Kretzer, Rainer Bader, Robert Sonntag

MARC

LEADER 00000caa a2200000 c 4500
001 155638260X
003 DE-627
005 20230426153652.0
007 cr uuu---uuuuu
008 170406s2015 xx |||||o 00| ||eng c
024 7 |a 10.1586/17434440.2015.1050378  |2 doi 
035 |a (DE-627)155638260X 
035 |a (DE-576)486382605 
035 |a (DE-599)BSZ486382605 
035 |a (OCoLC)1340972685 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Zietz, Carmen  |d 1981-  |e VerfasserIn  |0 (DE-588)1081455489  |0 (DE-627)846122375  |0 (DE-576)454422636  |4 aut 
245 1 0 |a Wear testing of total hip replacements under severe conditions  |c Carmen Zietz, Christian Fabry, Joern Reinders, Rebecca Dammer, Jan Philippe Kretzer, Rainer Bader, Robert Sonntag 
264 1 |c July 2015 
300 |a 18 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 06.04.2017 
520 |a Controlled wear testing of total hip replacements in hip joint simulators is a well-established and powerful method, giving an extensive prediction of the long-term clinical performance. To understand the wear behavior of a bearing and its limits under in vivo conditions, testing scenarios should be designed as physiologically as possible. Currently, the ISO standard protocol 14242 is the most common preclinical testing procedure for total hip replacements, based on a simplified gait cycle for normal walking conditions. However, in recent years, wear patterns have increasingly been observed on retrievals that cannot be replicated by the current standard. The purpose of this study is to review the severe testing conditions that enable the generation of clinically relevant wear rates and phenomena. These conditions include changes in loading and activity, third-body wear, surface topography, edge wear and the role of aging of the bearing materials. 
650 4 |a hip simulator 
650 4 |a retrieval analysis 
650 4 |a total hip arthroplasty 
650 4 |a tribology 
650 4 |a Wear simulation 
700 1 |a Reinders, Jörn  |d 1982-  |e VerfasserIn  |0 (DE-588)1068844167  |0 (DE-627)820817708  |0 (DE-576)428211445  |4 aut 
700 1 |a Kretzer, Jan Philippe  |d 1978-  |e VerfasserIn  |0 (DE-588)136998348  |0 (DE-627)589003690  |0 (DE-576)301383103  |4 aut 
773 0 8 |i Enthalten in  |t Expert review of medical devices  |d Abingdon : Taylor & Francis Group, 2004  |g 12(2015), 4, Seite 393-410  |h Online-Ressource  |w (DE-627)471684031  |w (DE-600)2167175-8  |w (DE-576)280458258  |x 1745-2422  |7 nnas  |a Wear testing of total hip replacements under severe conditions 
773 1 8 |g volume:12  |g year:2015  |g number:4  |g pages:393-410  |g extent:18  |a Wear testing of total hip replacements under severe conditions 
856 4 0 |u http://dx.doi.org/10.1586/17434440.2015.1050378  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://dx.doi.org/10.1586/17434440.2015.1050378  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20170406 
993 |a Article 
994 |a 2015 
998 |g 136998348  |a Kretzer, Jan Philippe  |m 136998348:Kretzer, Jan Philippe  |d 910000  |d 911460  |e 910000PK136998348  |e 911460PK136998348  |k 0/910000/  |k 1/910000/911460/  |p 5 
998 |g 1068844167  |a Reinders, Jörn  |m 1068844167:Reinders, Jörn  |d 50000  |e 50000PR1068844167  |k 0/50000/  |p 3 
999 |a KXP-PPN155638260X  |e 2964259917 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 06.04.2017"],"relHost":[{"id":{"eki":["471684031"],"issn":["1745-2422"],"zdb":["2167175-8"]},"part":{"extent":"18","issue":"4","volume":"12","text":"12(2015), 4, Seite 393-410","year":"2015","pages":"393-410"},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 09.09.15"],"origin":[{"publisher":"Taylor & Francis Group ; Future Drugs ; Expert Reviews ; Informa Healthcare","dateIssuedDisp":"2004-","dateIssuedKey":"2004","publisherPlace":"Abingdon ; London ; London ; London"}],"title":[{"title":"Expert review of medical devices","title_sort":"Expert review of medical devices"}],"pubHistory":["1.2004 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Wear testing of total hip replacements under severe conditionsExpert review of medical devices","recId":"471684031","language":["eng"]}],"physDesc":[{"extent":"18 S."}],"id":{"eki":["155638260X"],"doi":["10.1586/17434440.2015.1050378"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"Wear testing of total hip replacements under severe conditions","title":"Wear testing of total hip replacements under severe conditions"}],"language":["eng"],"person":[{"role":"aut","given":"Carmen","display":"Zietz, Carmen","family":"Zietz"},{"display":"Reinders, Jörn","given":"Jörn","family":"Reinders","role":"aut"},{"given":"Jan Philippe","display":"Kretzer, Jan Philippe","family":"Kretzer","role":"aut"}],"origin":[{"dateIssuedDisp":"July 2015","dateIssuedKey":"2015"}],"name":{"displayForm":["Carmen Zietz, Christian Fabry, Joern Reinders, Rebecca Dammer, Jan Philippe Kretzer, Rainer Bader, Robert Sonntag"]},"recId":"155638260X"} 
SRT |a ZIETZCARMEWEARTESTIN2015