Wear testing of total hip replacements under severe conditions
Controlled wear testing of total hip replacements in hip joint simulators is a well-established and powerful method, giving an extensive prediction of the long-term clinical performance. To understand the wear behavior of a bearing and its limits under in vivo conditions, testing scenarios should be...
Gespeichert in:
| Hauptverfasser: | , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
July 2015
|
| In: |
Expert review of medical devices
Year: 2015, Jahrgang: 12, Heft: 4, Pages: 393-410 |
| ISSN: | 1745-2422 |
| DOI: | 10.1586/17434440.2015.1050378 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1586/17434440.2015.1050378 |
| Verfasserangaben: | Carmen Zietz, Christian Fabry, Joern Reinders, Rebecca Dammer, Jan Philippe Kretzer, Rainer Bader, Robert Sonntag |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 155638260X | ||
| 003 | DE-627 | ||
| 005 | 20230426153652.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 170406s2015 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1586/17434440.2015.1050378 |2 doi | |
| 035 | |a (DE-627)155638260X | ||
| 035 | |a (DE-576)486382605 | ||
| 035 | |a (DE-599)BSZ486382605 | ||
| 035 | |a (OCoLC)1340972685 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Zietz, Carmen |d 1981- |e VerfasserIn |0 (DE-588)1081455489 |0 (DE-627)846122375 |0 (DE-576)454422636 |4 aut | |
| 245 | 1 | 0 | |a Wear testing of total hip replacements under severe conditions |c Carmen Zietz, Christian Fabry, Joern Reinders, Rebecca Dammer, Jan Philippe Kretzer, Rainer Bader, Robert Sonntag |
| 264 | 1 | |c July 2015 | |
| 300 | |a 18 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 06.04.2017 | ||
| 520 | |a Controlled wear testing of total hip replacements in hip joint simulators is a well-established and powerful method, giving an extensive prediction of the long-term clinical performance. To understand the wear behavior of a bearing and its limits under in vivo conditions, testing scenarios should be designed as physiologically as possible. Currently, the ISO standard protocol 14242 is the most common preclinical testing procedure for total hip replacements, based on a simplified gait cycle for normal walking conditions. However, in recent years, wear patterns have increasingly been observed on retrievals that cannot be replicated by the current standard. The purpose of this study is to review the severe testing conditions that enable the generation of clinically relevant wear rates and phenomena. These conditions include changes in loading and activity, third-body wear, surface topography, edge wear and the role of aging of the bearing materials. | ||
| 650 | 4 | |a hip simulator | |
| 650 | 4 | |a retrieval analysis | |
| 650 | 4 | |a total hip arthroplasty | |
| 650 | 4 | |a tribology | |
| 650 | 4 | |a Wear simulation | |
| 700 | 1 | |a Reinders, Jörn |d 1982- |e VerfasserIn |0 (DE-588)1068844167 |0 (DE-627)820817708 |0 (DE-576)428211445 |4 aut | |
| 700 | 1 | |a Kretzer, Jan Philippe |d 1978- |e VerfasserIn |0 (DE-588)136998348 |0 (DE-627)589003690 |0 (DE-576)301383103 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Expert review of medical devices |d Abingdon : Taylor & Francis Group, 2004 |g 12(2015), 4, Seite 393-410 |h Online-Ressource |w (DE-627)471684031 |w (DE-600)2167175-8 |w (DE-576)280458258 |x 1745-2422 |7 nnas |a Wear testing of total hip replacements under severe conditions |
| 773 | 1 | 8 | |g volume:12 |g year:2015 |g number:4 |g pages:393-410 |g extent:18 |a Wear testing of total hip replacements under severe conditions |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1586/17434440.2015.1050378 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1586/17434440.2015.1050378 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20170406 | ||
| 993 | |a Article | ||
| 994 | |a 2015 | ||
| 998 | |g 136998348 |a Kretzer, Jan Philippe |m 136998348:Kretzer, Jan Philippe |d 910000 |d 911460 |e 910000PK136998348 |e 911460PK136998348 |k 0/910000/ |k 1/910000/911460/ |p 5 | ||
| 998 | |g 1068844167 |a Reinders, Jörn |m 1068844167:Reinders, Jörn |d 50000 |e 50000PR1068844167 |k 0/50000/ |p 3 | ||
| 999 | |a KXP-PPN155638260X |e 2964259917 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Gesehen am 06.04.2017"],"relHost":[{"id":{"eki":["471684031"],"issn":["1745-2422"],"zdb":["2167175-8"]},"part":{"extent":"18","issue":"4","volume":"12","text":"12(2015), 4, Seite 393-410","year":"2015","pages":"393-410"},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 09.09.15"],"origin":[{"publisher":"Taylor & Francis Group ; Future Drugs ; Expert Reviews ; Informa Healthcare","dateIssuedDisp":"2004-","dateIssuedKey":"2004","publisherPlace":"Abingdon ; London ; London ; London"}],"title":[{"title":"Expert review of medical devices","title_sort":"Expert review of medical devices"}],"pubHistory":["1.2004 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Wear testing of total hip replacements under severe conditionsExpert review of medical devices","recId":"471684031","language":["eng"]}],"physDesc":[{"extent":"18 S."}],"id":{"eki":["155638260X"],"doi":["10.1586/17434440.2015.1050378"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"Wear testing of total hip replacements under severe conditions","title":"Wear testing of total hip replacements under severe conditions"}],"language":["eng"],"person":[{"role":"aut","given":"Carmen","display":"Zietz, Carmen","family":"Zietz"},{"display":"Reinders, Jörn","given":"Jörn","family":"Reinders","role":"aut"},{"given":"Jan Philippe","display":"Kretzer, Jan Philippe","family":"Kretzer","role":"aut"}],"origin":[{"dateIssuedDisp":"July 2015","dateIssuedKey":"2015"}],"name":{"displayForm":["Carmen Zietz, Christian Fabry, Joern Reinders, Rebecca Dammer, Jan Philippe Kretzer, Rainer Bader, Robert Sonntag"]},"recId":"155638260X"} | ||
| SRT | |a ZIETZCARMEWEARTESTIN2015 | ||