Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion

Objective: To compare six different scenarios for correcting for breathing motion in abdominal dual-energy CT (DECT) perfusion measurements. Methods: Rigid [RRComm(80 kVp)] and non-rigid [NRComm(80 kVp)] registration of commercially available CT perfusion software, custom non-rigid registration [NRC...

Full description

Saved in:
Bibliographic Details
Main Authors: Skornitzke, Stephan (Author) , Fritz, Franziska (Author) , Klauß, Miriam (Author) , Pahn, Gregor (Author) , Hansen, Jens (Author) , Grenacher, Lars (Author) , Kauczor, Hans-Ulrich (Author) , Stiller, Wolfram (Author)
Format: Article (Journal)
Language:English
Published: 2015, Jan 16
In: British journal of radiology
Year: 2015, Volume: 88, Issue: 1046
ISSN:1748-880X
DOI:10.1259/bjr.20140683
Online Access:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1259/bjr.20140683
Verlag, kostenfrei, Volltext: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614238/
Get full text
Author Notes:S Skornitzke, MSc, F Fritz, MD, M Klauss, MD, G Pahn, MSc, J Hansen, MSc, J Hirsch, PhD, L Grenacher, MD, H-U Kauczor, MD and W Stiller, PhD

MARC

LEADER 00000caa a2200000 c 4500
001 1560459603
003 DE-627
005 20220813190348.0
007 cr uuu---uuuuu
008 170704s2015 xx |||||o 00| ||eng c
024 7 |a 10.1259/bjr.20140683  |2 doi 
035 |a (DE-627)1560459603 
035 |a (DE-576)490459609 
035 |a (DE-599)BSZ490459609 
035 |a (OCoLC)1340976488 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Skornitzke, Stephan  |d 1987-  |e VerfasserIn  |0 (DE-588)1110072589  |0 (DE-627)864783523  |0 (DE-576)475718267  |4 aut 
245 1 0 |a Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion  |c S Skornitzke, MSc, F Fritz, MD, M Klauss, MD, G Pahn, MSc, J Hansen, MSc, J Hirsch, PhD, L Grenacher, MD, H-U Kauczor, MD and W Stiller, PhD 
264 1 |c 2015, Jan 16 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 04.07.2017 
520 |a Objective: To compare six different scenarios for correcting for breathing motion in abdominal dual-energy CT (DECT) perfusion measurements. Methods: Rigid [RRComm(80 kVp)] and non-rigid [NRComm(80 kVp)] registration of commercially available CT perfusion software, custom non-rigid registration [NRCustom(80 kVp], demons algorithm) and a control group [CG(80 kVp)] without motion correction were evaluated using 80 kVp images. Additionally, NRCustom was applied to dual-energy (DE)-blended [NRCustom(DE)] and virtual non-contrast [NRCustom(VNC)] images, yielding six evaluated scenarios. After motion correction, perfusion maps were calculated using a combined maximum slope/Patlak model. For qualitative evaluation, three blinded radiologists independently rated motion correction quality and resulting perfusion maps on a four-point scale (4 = best, 1 = worst). For quantitative evaluation, relative changes in metric values, R2 and residuals of perfusion model fits were calculated. Results: For motion-corrected images, mean ratings differed significantly [NRCustom(80 kVp) and NRCustom(DE), 3.3; NRComm(80 kVp), 3.1; NRCustom(VNC), 2.9; RRComm(80 kVp), 2.7; CG(80 kVp), 2.7; all p < 0.05], except when comparing NRCustom(80 kVp) with NRCustom(DE) and RRComm(80 kVp) with CG(80 kVp). NRCustom(80 kVp) and NRCustom(DE) achieved the highest reduction in metric values [NRCustom(80 kVp), 48.5%; NRCustom(DE), 45.6%; NRComm(80 kVp), 29.2%; NRCustom(VNC), 22.8%; RRComm(80 kVp), 0.6%; CG(80 kVp), 0%]. Regarding perfusion maps, NRCustom(80 kVp) and NRCustom(DE) were rated highest [NRCustom(80 kVp), 3.1; NRCustom(DE), 3.0; NRComm(80 kVp), 2.8; NRCustom(VNC), 2.6; CG(80 kVp), 2.5; RRComm(80 kVp), 2.4] and had significantly higher R2 and lower residuals. Correlation between qualitative and quantitative evaluation was low to moderate. Conclusion: Non-rigid motion correction improves spatial alignment of the target region and fit of CT perfusion models. Using DE-blended and DE-VNC images for deformable registration offers no significant improvement. Advances in knowledge: Non-rigid algorithms improve the quality of abdominal CT perfusion measurements but do not benefit from DECT post processing. 
700 1 |a Fritz, Franziska  |d 1986-  |e VerfasserIn  |0 (DE-588)1041966393  |0 (DE-627)768050987  |0 (DE-576)393612600  |4 aut 
700 1 |a Klauß, Miriam  |d 1978-  |e VerfasserIn  |0 (DE-588)130870552  |0 (DE-627)506783839  |0 (DE-576)29838728X  |4 aut 
700 1 |a Pahn, Gregor  |e VerfasserIn  |0 (DE-588)1120442567  |0 (DE-627)873380088  |0 (DE-576)480343551  |4 aut 
700 1 |a Hansen, Jens  |d 1986-  |e VerfasserIn  |0 (DE-588)1120442427  |0 (DE-627)873379683  |0 (DE-576)480343144  |4 aut 
700 1 |a Grenacher, Lars  |d 1967-  |e VerfasserIn  |0 (DE-588)115424598  |0 (DE-627)691308977  |0 (DE-576)289876761  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Stiller, Wolfram  |d 1976-  |e VerfasserIn  |0 (DE-588)105822672X  |0 (DE-627)796627495  |0 (DE-576)414249496  |4 aut 
773 0 8 |i Enthalten in  |t British journal of radiology  |d Oxford : Oxford University Press, 1928  |g 88(2015), 1046  |w (DE-627)266886744  |w (DE-600)1468548-6  |w (DE-576)079420168  |x 1748-880X  |7 nnas  |a Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion 
773 1 8 |g volume:88  |g year:2015  |g number:1046  |g extent:11  |a Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion 
856 4 0 |u http://dx.doi.org/10.1259/bjr.20140683  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614238/  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20170704 
993 |a Article 
994 |a 2015 
998 |g 105822672X  |a Stiller, Wolfram  |m 105822672X:Stiller, Wolfram  |d 910000  |d 911400  |e 910000PS105822672X  |e 911400PS105822672X  |k 0/910000/  |k 1/910000/911400/  |p 9  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 115424598  |a Grenacher, Lars  |m 115424598:Grenacher, Lars  |d 910000  |d 911400  |e 910000PG115424598  |e 911400PG115424598  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1120442427  |a Hansen, Jens  |m 1120442427:Hansen, Jens  |d 910000  |d 911400  |e 910000PH1120442427  |e 911400PH1120442427  |k 0/910000/  |k 1/910000/911400/  |p 5 
998 |g 1120442567  |a Pahn, Gregor  |m 1120442567:Pahn, Gregor  |d 910000  |d 911400  |e 910000PP1120442567  |e 911400PP1120442567  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 130870552  |a Klauß, Miriam  |m 130870552:Klauß, Miriam  |d 910000  |d 911400  |e 910000PK130870552  |e 911400PK130870552  |k 0/910000/  |k 1/910000/911400/  |p 3 
998 |g 1041966393  |a Fritz, Franziska  |m 1041966393:Fritz, Franziska  |d 910000  |d 911400  |e 910000PF1041966393  |e 911400PF1041966393  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1110072589  |a Skornitzke, Stephan  |m 1110072589:Skornitzke, Stephan  |d 910000  |d 911400  |e 910000PS1110072589  |e 911400PS1110072589  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1560459603  |e 2973147352 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"11 S."}],"recId":"1560459603","relHost":[{"recId":"266886744","disp":"Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motionBritish journal of radiology","origin":[{"publisher":"Oxford University Press ; British Institute of Radiology ; Wiley","dateIssuedDisp":"2024-","dateIssuedKey":"2024","publisherPlace":"Oxford ; London ; Bognor Regis"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 27.09.24"],"title":[{"title_sort":"British journal of radiology","title":"British journal of radiology","subtitle":"BJR : an international journal of radiology, radiation oncology and all related sciences"}],"corporate":[{"display":"British Institute of Radiology","role":"isb"},{"display":"Röntgen Society","role":"isb"}],"name":{"displayForm":["British Institute of Radiology"]},"pubHistory":["1.1928 -"],"titleAlt":[{"title":"BJR online"}],"id":{"doi":["10.1259/(ISSN)1748-880X"],"zdb":["1468548-6"],"eki":["266886744"],"issn":["1748-880X"]},"part":{"extent":"11","text":"88(2015), 1046","volume":"88","issue":"1046","year":"2015"}}],"person":[{"display":"Skornitzke, Stephan","family":"Skornitzke","given":"Stephan","role":"aut"},{"given":"Franziska","role":"aut","family":"Fritz","display":"Fritz, Franziska"},{"family":"Klauß","role":"aut","given":"Miriam","display":"Klauß, Miriam"},{"display":"Pahn, Gregor","role":"aut","given":"Gregor","family":"Pahn"},{"display":"Hansen, Jens","family":"Hansen","role":"aut","given":"Jens"},{"family":"Grenacher","given":"Lars","role":"aut","display":"Grenacher, Lars"},{"given":"Hans-Ulrich","role":"aut","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"role":"aut","given":"Wolfram","family":"Stiller","display":"Stiller, Wolfram"}],"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"2015, Jan 16"}],"note":["Gesehen am 04.07.2017"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title":"Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion","title_sort":"Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion"}],"name":{"displayForm":["S Skornitzke, MSc, F Fritz, MD, M Klauss, MD, G Pahn, MSc, J Hansen, MSc, J Hirsch, PhD, L Grenacher, MD, H-U Kauczor, MD and W Stiller, PhD"]},"id":{"doi":["10.1259/bjr.20140683"],"eki":["1560459603"]}} 
SRT |a SKORNITZKEQUALITATIV2015