Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance: a phantom study

Objective: Evaluation of absolute radiation exposure values for interventional radiologists (IRs) using a multiaxis interventional flat-panel C-arm cone beam CT (CBCT) system with three-dimensional laser guidance for biopsy in a triple-modality, abdominal phantom. Methods: In the phantom, eight lesi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rathmann, Nils-Andreas (VerfasserIn) , Bartling, Sönke (VerfasserIn) , Haubenreisser, Holger (VerfasserIn) , Schönberg, Stefan (VerfasserIn) , Diehl, Steffen J. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: October 06, 2015
In: British journal of radiology
Year: 2015, Jahrgang: 88, Heft: 1055, Pages: 20150151
ISSN:1748-880X
DOI:10.1259/bjr.20150151
Online-Zugang:Verlag, teilw. kostenfrei, Volltext: http://dx.doi.org/10.1259/bjr.20150151
Verlag, teilw. kostenfrei, Volltext: http://www.birpublications.org.ezproxy.medma.uni-heidelberg.de/doi/10.1259/bjr.20150151
Volltext
Verfasserangaben:Nils Rathmann, Michael Kostrzewa, Kerim Kara, Soenke Bartling, Holger Haubenreisser, Stefan O Schoenberg, Steffen J Diehl

MARC

LEADER 00000caa a2200000 c 4500
001 1560484802
003 DE-627
005 20220813190548.0
007 cr uuu---uuuuu
008 170705s2015 xx |||||o 00| ||eng c
024 7 |a 10.1259/bjr.20150151  |2 doi 
035 |a (DE-627)1560484802 
035 |a (DE-576)490484808 
035 |a (DE-599)BSZ490484808 
035 |a (OCoLC)1340976466 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rathmann, Nils-Andreas  |d 1982-  |e VerfasserIn  |0 (DE-588)140996923  |0 (DE-627)703853538  |0 (DE-576)321542940  |4 aut 
245 1 0 |a Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance  |b a phantom study  |c Nils Rathmann, Michael Kostrzewa, Kerim Kara, Soenke Bartling, Holger Haubenreisser, Stefan O Schoenberg, Steffen J Diehl 
264 1 |c October 06, 2015 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 05.07.2017 
520 |a Objective: Evaluation of absolute radiation exposure values for interventional radiologists (IRs) using a multiaxis interventional flat-panel C-arm cone beam CT (CBCT) system with three-dimensional laser guidance for biopsy in a triple-modality, abdominal phantom. Methods: In the phantom, eight lesions were punctured in two different angles (in- and out-of-plane) using CBCT. One C-arm CT scan was performed to plan the intervention and one for post-procedural evaluation. Thermoluminescent dosemeters (TLDs) were used for dose measurement at the level of the eye lens, umbilicus and ankles on a pole representing the IRs. All measurements were performed without any lead protection. In addition, the dose-area product (DAP) and air kerma at the skin entrance point was documented. Results: Mean radiation values of all TLDs were 190 µSv for CBCT (eye lens: 180 µS, umbilicus: 230 µSv, ankle: 150 µSv) without a significant difference (p > 0.005) between in- and out-of-plane biopsies. In terms of radiation exposure of the phantom, the mean DAP was not statistically significantly different (p > 0.05) for in- and out-of-plane biopsies. Fluoroscopy showed a mean DAP of 7 or 6 μGym2, respectively. C-arm CT showed a mean DAP of 5150 or 5130 μGym2, respectively. Conclusion: In our setting, the radiation dose to the IR was distinctly high using CBCT. For dose reduction, it is advisable to pay attention to lead shielding, to increase the distance to the X-ray source and to leave the intervention suite for C-arm CT scans. Advances in knowledge: The results indicate that using modern navigation tools and CBCT can be accompanied with a relative high radiation dose for the IRs since detector angulation can make the use of proper lead shielding difficult. 
700 1 |a Bartling, Sönke  |d 1976-  |e VerfasserIn  |0 (DE-588)129985961  |0 (DE-627)486230929  |0 (DE-576)297935712  |4 aut 
700 1 |a Haubenreisser, Holger  |d 1985-  |e VerfasserIn  |0 (DE-588)1050055322  |0 (DE-627)783257791  |0 (DE-576)404356281  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Diehl, Steffen J.  |e VerfasserIn  |0 (DE-588)1020240881  |0 (DE-627)691154120  |0 (DE-576)359785522  |4 aut 
773 0 8 |i Enthalten in  |t British journal of radiology  |d Oxford : Oxford University Press, 1928  |g 88(2015), 1055, Seite 20150151  |w (DE-627)266886744  |w (DE-600)1468548-6  |w (DE-576)079420168  |x 1748-880X  |7 nnas  |a Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance a phantom study 
773 1 8 |g volume:88  |g year:2015  |g number:1055  |g pages:20150151  |g extent:7  |a Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance a phantom study 
856 4 0 |u http://dx.doi.org/10.1259/bjr.20150151  |x Verlag  |x Resolving-System  |z teilw. kostenfrei  |3 Volltext 
856 4 0 |u http://www.birpublications.org.ezproxy.medma.uni-heidelberg.de/doi/10.1259/bjr.20150151  |x Verlag  |z teilw. kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20170705 
993 |a Article 
994 |a 2015 
998 |g 1020240881  |a Diehl, Steffen J.  |m 1020240881:Diehl, Steffen J.  |d 60000  |d 62900  |e 60000PD1020240881  |e 62900PD1020240881  |k 0/60000/  |k 1/60000/62900/  |p 7  |y j 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |e 60000PS131557912  |e 62900PS131557912  |k 0/60000/  |k 1/60000/62900/  |p 6 
998 |g 1050055322  |a Haubenreisser, Holger  |m 1050055322:Haubenreisser, Holger  |d 60000  |d 62900  |e 60000PH1050055322  |e 62900PH1050055322  |k 0/60000/  |k 1/60000/62900/  |p 5 
998 |g 129985961  |a Bartling, Sönke  |m 129985961:Bartling, Sönke  |d 60000  |d 62900  |e 60000PB129985961  |e 62900PB129985961  |k 0/60000/  |k 1/60000/62900/  |p 4 
998 |g 140996923  |a Rathmann, Nils-Andreas  |m 140996923:Rathmann, Nils-Andreas  |d 60000  |d 62900  |e 60000PR140996923  |e 62900PR140996923  |k 0/60000/  |k 1/60000/62900/  |p 1  |x j 
999 |a KXP-PPN1560484802  |e 2973182948 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 05.07.2017"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"title":[{"title":"Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance","title_sort":"Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance","subtitle":"a phantom study"}],"person":[{"display":"Rathmann, Nils-Andreas","family":"Rathmann","given":"Nils-Andreas","role":"aut"},{"role":"aut","given":"Sönke","family":"Bartling","display":"Bartling, Sönke"},{"display":"Haubenreisser, Holger","family":"Haubenreisser","role":"aut","given":"Holger"},{"display":"Schönberg, Stefan","family":"Schönberg","role":"aut","given":"Stefan"},{"display":"Diehl, Steffen J.","given":"Steffen J.","role":"aut","family":"Diehl"}],"relHost":[{"pubHistory":["1.1928 -"],"titleAlt":[{"title":"BJR online"}],"name":{"displayForm":["British Institute of Radiology"]},"corporate":[{"display":"British Institute of Radiology","role":"isb"},{"display":"Röntgen Society","role":"isb"}],"part":{"pages":"20150151","text":"88(2015), 1055, Seite 20150151","extent":"7","issue":"1055","year":"2015","volume":"88"},"id":{"eki":["266886744"],"issn":["1748-880X"],"doi":["10.1259/(ISSN)1748-880X"],"zdb":["1468548-6"]},"recId":"266886744","disp":"Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance a phantom studyBritish journal of radiology","origin":[{"publisher":"Oxford University Press ; British Institute of Radiology ; Wiley","publisherPlace":"Oxford ; London ; Bognor Regis","dateIssuedKey":"2024","dateIssuedDisp":"2024-"}],"title":[{"subtitle":"BJR : an international journal of radiology, radiation oncology and all related sciences","title":"British journal of radiology","title_sort":"British journal of radiology"}],"note":["Gesehen am 27.09.24"],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"]}],"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"October 06, 2015"}],"physDesc":[{"extent":"7 S."}],"recId":"1560484802","id":{"eki":["1560484802"],"doi":["10.1259/bjr.20150151"]},"name":{"displayForm":["Nils Rathmann, Michael Kostrzewa, Kerim Kara, Soenke Bartling, Holger Haubenreisser, Stefan O Schoenberg, Steffen J Diehl"]}} 
SRT |a RATHMANNNIRADIATIONE0620