Computer-aided detection of artificial pulmonary nodules using an ex vivo lung phantom: influence of exposure parameters and iterative reconstruction

To evaluate the influence of exposure parameters and raw-data based iterative reconstruction (IR) on the performance of computer-aided detection (CAD) of pulmonary nodules on chest multidetector computed tomography (MDCT). Seven porcine lung explants were inflated in a dedicated ex vivo phantom shel...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wielpütz, Mark Oliver (VerfasserIn) , Wroblewski, Jacek (VerfasserIn) , Dinkel, Julien (VerfasserIn) , Eichinger, Monika (VerfasserIn) , Biederer, Jürgen (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Puderbach, Michael (VerfasserIn) , Jobst, Bertram (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 16 February 2015
In: European journal of radiology
Year: 2015, Jahrgang: 84, Heft: 5, Pages: 1005-1011
ISSN:1872-7727
DOI:10.1016/j.ejrad.2015.01.025
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.ejrad.2015.01.025
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X15000716
Volltext
Verfasserangaben:Mark O. Wielpütz, Jacek Wroblewski, Mathieu Lederlin, Julien Dinkel, Monika Eichinger, M. Koenigkam-Santos, Jürgen Biederer, Hans-Ulrich Kauczor, Michael U. Puderbach, Bertram J. Jobst

MARC

LEADER 00000caa a2200000 c 4500
001 1560554258
003 DE-627
005 20220813191547.0
007 cr uuu---uuuuu
008 170706s2015 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2015.01.025  |2 doi 
035 |a (DE-627)1560554258 
035 |a (DE-576)490554253 
035 |a (DE-599)BSZ490554253 
035 |a (OCoLC)1340976765 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Wielpütz, Mark Oliver  |d 1982-  |e VerfasserIn  |0 (DE-588)139999752  |0 (DE-627)614754682  |0 (DE-576)314127046  |4 aut 
245 1 0 |a Computer-aided detection of artificial pulmonary nodules using an ex vivo lung phantom  |b influence of exposure parameters and iterative reconstruction  |c Mark O. Wielpütz, Jacek Wroblewski, Mathieu Lederlin, Julien Dinkel, Monika Eichinger, M. Koenigkam-Santos, Jürgen Biederer, Hans-Ulrich Kauczor, Michael U. Puderbach, Bertram J. Jobst 
264 1 |c 16 February 2015 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 06.07.2017 
520 |a To evaluate the influence of exposure parameters and raw-data based iterative reconstruction (IR) on the performance of computer-aided detection (CAD) of pulmonary nodules on chest multidetector computed tomography (MDCT). Seven porcine lung explants were inflated in a dedicated ex vivo phantom shell and prepared with n=162 artificial nodules of a clinically relevant volume and maximum diameter (46-1063μl, and 6.2-21.5mm). n=118 nodules were solid and n=44 part-solid. MDCT was performed with different combinations of 120 and 80kV with 120, 60, 30 and 12mA*s, and reconstructed with both filtered back projection (FBP) and IR. Subsequently, 16 datasets per lung were subjected to dedicated CAD software. The rate of true positive, false negative and false positive CAD marks was measured for each reconstruction. The rate of true positive findings ranged between 88.9-91.4% for FBP and 88.3-90.1% for IR (n.s.) with most exposure settings, but was significantly lower with the combination of 80kV and 12mA*s (80.9% and 81.5%, respectively, p<0.05). False positive findings ranged between 2.3 - 8.1 annotations per lung. For nodule volumes <200μl the rate of true positives was significantly lower than for >300μl (p<0.05). Similarly, it was significantly lower for diameters <12mm compared to ≥12mm (p<0.05). The rate of true positives for solid and part-solid nodules was similar. Nodule CAD on chest MDCT is robust over a wide range of exposure settings. Noise reduction by IR is not detrimental for CAD, and may be used to improve image quality in the setting of low-dose MDCT for lung cancer screening. 
650 4 |a CAD 
650 4 |a Computer-aided diagnosis 
650 4 |a Low-dose CT 
650 4 |a Lung cancer screening 
700 1 |a Wroblewski, Jacek  |d 1982-  |e VerfasserIn  |0 (DE-588)1136449035  |0 (DE-627)892933798  |0 (DE-576)490553729  |4 aut 
700 1 |a Dinkel, Julien  |d 1978-  |e VerfasserIn  |0 (DE-588)140755632  |0 (DE-627)621592773  |0 (DE-576)320647374  |4 aut 
700 1 |a Eichinger, Monika  |d 1964-  |e VerfasserIn  |0 (DE-588)1049617525  |0 (DE-627)78269117X  |0 (DE-576)172609712  |4 aut 
700 1 |a Biederer, Jürgen  |d 1969-  |e VerfasserIn  |0 (DE-588)141247282  |0 (DE-627)625830857  |0 (DE-576)322978122  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Puderbach, Michael  |d 1974-  |e VerfasserIn  |0 (DE-588)123953669  |0 (DE-627)085545880  |0 (DE-576)293957452  |4 aut 
700 1 |a Jobst, Bertram  |d 1982-  |e VerfasserIn  |0 (DE-588)1072564750  |0 (DE-627)827728840  |0 (DE-576)434033766  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 84(2015), 5, Seite 1005-1011  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a Computer-aided detection of artificial pulmonary nodules using an ex vivo lung phantom influence of exposure parameters and iterative reconstruction 
773 1 8 |g volume:84  |g year:2015  |g number:5  |g pages:1005-1011  |g extent:7  |a Computer-aided detection of artificial pulmonary nodules using an ex vivo lung phantom influence of exposure parameters and iterative reconstruction 
856 4 0 |u http://dx.doi.org/10.1016/j.ejrad.2015.01.025  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0720048X15000716  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20170706 
993 |a Article 
994 |a 2015 
998 |g 1072564750  |a Jobst, Bertram  |m 1072564750:Jobst, Bertram  |d 910000  |d 911400  |e 910000PJ1072564750  |e 911400PJ1072564750  |k 0/910000/  |k 1/910000/911400/  |p 10  |y j 
998 |g 123953669  |a Puderbach, Michael  |m 123953669:Puderbach, Michael  |d 910000  |d 950000  |d 950900  |e 910000PP123953669  |e 950000PP123953669  |e 950900PP123953669  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 9 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 141247282  |a Biederer, Jürgen  |m 141247282:Biederer, Jürgen  |d 910000  |d 911400  |e 910000PB141247282  |e 911400PB141247282  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1049617525  |a Eichinger, Monika  |m 1049617525:Eichinger, Monika  |d 910000  |d 950000  |d 950900  |e 910000PE1049617525  |e 950000PE1049617525  |e 950900PE1049617525  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950900/  |p 5 
998 |g 140755632  |a Dinkel, Julien  |m 140755632:Dinkel, Julien  |d 910000  |d 911400  |e 910000PD140755632  |e 911400PD140755632  |k 0/910000/  |k 1/910000/911400/  |p 4 
998 |g 1136449035  |a Wroblewski, Jacek  |m 1136449035:Wroblewski, Jacek  |d 910000  |d 911400  |e 910000PW1136449035  |e 911400PW1136449035  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 139999752  |a Wielpütz, Mark Oliver  |m 139999752:Wielpütz, Mark Oliver  |d 910000  |d 911400  |e 910000PW139999752  |e 911400PW139999752  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1560554258  |e 2973285771 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1560554258"],"doi":["10.1016/j.ejrad.2015.01.025"]},"name":{"displayForm":["Mark O. Wielpütz, Jacek Wroblewski, Mathieu Lederlin, Julien Dinkel, Monika Eichinger, M. Koenigkam-Santos, Jürgen Biederer, Hans-Ulrich Kauczor, Michael U. Puderbach, Bertram J. Jobst"]},"physDesc":[{"extent":"7 S."}],"recId":"1560554258","note":["Gesehen am 06.07.2017"],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"subtitle":"influence of exposure parameters and iterative reconstruction","title":"Computer-aided detection of artificial pulmonary nodules using an ex vivo lung phantom","title_sort":"Computer-aided detection of artificial pulmonary nodules using an ex vivo lung phantom"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"recId":"32044483X","disp":"Computer-aided detection of artificial pulmonary nodules using an ex vivo lung phantom influence of exposure parameters and iterative reconstructionEuropean journal of radiology","origin":[{"publisher":"Elsevier Science","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisherPlace":"Amsterdam [u.a.]"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 05.02.20"],"title":[{"title_sort":"European journal of radiology","title":"European journal of radiology","subtitle":"EJR"}],"titleAlt":[{"title":"EJR"}],"pubHistory":["Nachgewiesen 10.1990 -"],"id":{"zdb":["2005350-2"],"eki":["32044483X"],"issn":["1872-7727"]},"part":{"year":"2015","volume":"84","pages":"1005-1011","extent":"7","text":"84(2015), 5, Seite 1005-1011","issue":"5"}}],"person":[{"display":"Wielpütz, Mark Oliver","family":"Wielpütz","role":"aut","given":"Mark Oliver"},{"display":"Wroblewski, Jacek","family":"Wroblewski","given":"Jacek","role":"aut"},{"display":"Dinkel, Julien","role":"aut","given":"Julien","family":"Dinkel"},{"display":"Eichinger, Monika","given":"Monika","role":"aut","family":"Eichinger"},{"family":"Biederer","given":"Jürgen","role":"aut","display":"Biederer, Jürgen"},{"given":"Hans-Ulrich","role":"aut","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"given":"Michael","role":"aut","family":"Puderbach","display":"Puderbach, Michael"},{"display":"Jobst, Bertram","family":"Jobst","role":"aut","given":"Bertram"}],"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"16 February 2015"}]} 
SRT |a WIELPUETZMCOMPUTERAI1620