Fluence inhomogeneities due to a ripple filter induced Moiré effect

At particle therapy facilities with pencil beam scanning, the implementation of a ripple filter (RiFi) broadens the Bragg peak, so fewer energy steps from the accelerator are required for a homogeneous dose coverage of the planning target volume (PTV). However, sharply focusing the scanned pencil be...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Ringbæk, Toke Printz (VerfasserIn) , Brons, Stephan (VerfasserIn) , Naumann, Jakob (VerfasserIn) , Ackermann, Benjamin (VerfasserIn) , Horn, Julian (VerfasserIn) , Latzel, Harald (VerfasserIn) , Scheloske, Stefan (VerfasserIn) , Galonska, Michael (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 15 January 2015
In: Physics in medicine and biology
Year: 2015, Jahrgang: 60, Heft: 3, Pages: N59-N69
ISSN:1361-6560
DOI:10.1088/0031-9155/60/3/N59
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1088/0031-9155/60/3/N59
Verlag, Volltext: http://stacks.iop.org/0031-9155/60/i=3/a=N59
Volltext
Verfasserangaben:Toke Printz Ringbæk, Stephan Brons, Jakob Naumann, Benjamin Ackermann, Julian Horn, Harald Latzel, Stefan Scheloske, Michael Galonska, Niels Bassler, Klemens Zink and Uli Weber

MARC

LEADER 00000caa a2200000 c 4500
001 156078363X
003 DE-627
005 20230428162100.0
007 cr uuu---uuuuu
008 170712s2015 xx |||||o 00| ||eng c
024 7 |a 10.1088/0031-9155/60/3/N59  |2 doi 
035 |a (DE-627)156078363X 
035 |a (DE-576)490783635 
035 |a (DE-599)BSZ490783635 
035 |a (OCoLC)1340977131 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Ringbæk, Toke Printz  |e VerfasserIn  |0 (DE-588)1136682570  |0 (DE-627)893445649  |0 (DE-576)490777430  |4 aut 
245 1 0 |a Fluence inhomogeneities due to a ripple filter induced Moiré effect  |c Toke Printz Ringbæk, Stephan Brons, Jakob Naumann, Benjamin Ackermann, Julian Horn, Harald Latzel, Stefan Scheloske, Michael Galonska, Niels Bassler, Klemens Zink and Uli Weber 
264 1 |c 15 January 2015 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 12.07.2017 
520 |a At particle therapy facilities with pencil beam scanning, the implementation of a ripple filter (RiFi) broadens the Bragg peak, so fewer energy steps from the accelerator are required for a homogeneous dose coverage of the planning target volume (PTV). However, sharply focusing the scanned pencil beams at the RiFi plane by ion optical settings can lead to a Moiré effect, causing fluence inhomogeneities at the isocenter. This has been experimentally proven at the Heidelberg Ionenstrahl-Therapiezentrum (HIT), Universitätsklinikum Heidelberg, Germany. 150 MeV u −1 carbon-12 ions are used for irradiation with a 3 mm thick RiFi. The beam is focused in front of and as close to the RiFi plane as possible. The pencil beam width is estimated to be 0.78 mm at a 93 mm distance from the RiFi. Radiographic films are used to obtain the fluence profile 30 mm in front of the isocenter, 930 mm from the RiFi. The Monte Carlo (MC) code SHIELD-HIT12A is used to determine the RiFi-induced inhomogeneities in the fluence distribution at the isocenter for a similar setup, pencil beam widths at the RiFi plane ranging from ##IMG## [http://ej.iop.org/images/0031-9155/60/3/N59/pmb506424ieqn001.gif] $\sigma _x^\textRiFi=0.56$ to 1.2 mm and for scanning step sizes ranging from 1.5 to 3.7 mm. The beam application and monitoring system (BAMS) used at HIT is modelled and simulated. When the width of the pencil beams at the RiFi plane is much smaller than the scanning step size, the resulting inhomogeneous fluence distribution at the RiFi plane interfers with the inhomogeneous RiFi mass distribution and fluence inhomogeneity can be observed at the isocenter as large as an 8% deviation from the mean fluence. The inverse of the fluence ripple period at the isocenter is found to be the difference between the inverse of the RiFi period and the inverse of the scanning step size. We have been able to use MC simulations to reproduce the spacing of the ripple stripes seen in films irradiated at HIT. Our findings clearly indicate that pencil beams sharply focused near the RiFi plane result in fluence inhomogeneity at the isocenter. In the normal clinical application, such a setting should generally be avoided. 
700 1 |a Brons, Stephan  |e VerfasserIn  |0 (DE-588)1072782375  |0 (DE-627)828233594  |0 (DE-576)434240478  |4 aut 
700 1 |a Naumann, Jakob  |d 1969-  |e VerfasserIn  |0 (DE-588)123702291  |0 (DE-627)706401565  |0 (DE-576)293834199  |4 aut 
700 1 |a Ackermann, Benjamin  |d 1979-  |e VerfasserIn  |0 (DE-588)1066758417  |0 (DE-627)817931562  |0 (DE-576)426134141  |4 aut 
700 1 |a Horn, Julian  |e VerfasserIn  |0 (DE-588)1136684514  |0 (DE-627)893450219  |0 (DE-576)490781551  |4 aut 
700 1 |a Latzel, Harald  |e VerfasserIn  |0 (DE-588)1136685138  |0 (DE-627)893458244  |0 (DE-576)490782868  |4 aut 
700 1 |a Scheloske, Stefan  |e VerfasserIn  |0 (DE-588)1136684956  |0 (DE-627)893451959  |0 (DE-576)490782450  |4 aut 
700 1 |a Galonska, Michael  |d 1970-  |e VerfasserIn  |0 (DE-588)1013630459  |0 (DE-627)664627226  |0 (DE-576)347463878  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 60(2015), 3, Seite N59-N69  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Fluence inhomogeneities due to a ripple filter induced Moiré effect 
773 1 8 |g volume:60  |g year:2015  |g number:3  |g pages:N59-N69  |g extent:11  |a Fluence inhomogeneities due to a ripple filter induced Moiré effect 
856 4 0 |u http://dx.doi.org/10.1088/0031-9155/60/3/N59  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://stacks.iop.org/0031-9155/60/i=3/a=N59  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20170712 
993 |a Article 
994 |a 2015 
998 |g 1013630459  |a Galonska, Michael  |m 1013630459:Galonska, Michael  |p 8 
998 |g 1136684956  |a Scheloske, Stefan  |m 1136684956:Scheloske, Stefan  |p 7 
998 |g 1136685138  |a Latzel, Harald  |m 1136685138:Latzel, Harald  |d 910000  |d 950000  |d 950400  |e 910000PL1136685138  |e 950000PL1136685138  |e 950400PL1136685138  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 6 
998 |g 1136684514  |a Horn, Julian  |m 1136684514:Horn, Julian  |d 910000  |d 950000  |d 950400  |e 910000PH1136684514  |e 950000PH1136684514  |e 950400PH1136684514  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 5 
998 |g 1066758417  |a Ackermann, Benjamin  |m 1066758417:Ackermann, Benjamin  |d 910000  |d 950000  |d 950400  |e 910000PA1066758417  |e 950000PA1066758417  |e 950400PA1066758417  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 4 
998 |g 123702291  |a Naumann, Jakob  |m 123702291:Naumann, Jakob  |d 910000  |d 950000  |d 950400  |e 910000PN123702291  |e 950000PN123702291  |e 950400PN123702291  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 3 
998 |g 1072782375  |a Brons, Stephan  |m 1072782375:Brons, Stephan  |p 2 
999 |a KXP-PPN156078363X  |e 2973904145 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"Fluence inhomogeneities due to a ripple filter induced Moiré effect","title_sort":"Fluence inhomogeneities due to a ripple filter induced Moiré effect"}],"physDesc":[{"extent":"11 S."}],"relHost":[{"recId":"269016163","id":{"zdb":["1473501-5"],"eki":["269016163"],"issn":["1361-6560"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Fluence inhomogeneities due to a ripple filter induced Moiré effectPhysics in medicine and biology","origin":[{"publisherPlace":"Bristol","dateIssuedKey":"1956","dateIssuedDisp":"1956-","publisher":"IOP Publ."}],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"pubHistory":["1.1956 -"],"language":["eng"],"part":{"issue":"3","pages":"N59-N69","year":"2015","extent":"11","volume":"60","text":"60(2015), 3, Seite N59-N69"},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology"}]}],"person":[{"given":"Toke Printz","family":"Ringbæk","role":"aut","display":"Ringbæk, Toke Printz"},{"role":"aut","family":"Brons","display":"Brons, Stephan","given":"Stephan"},{"given":"Jakob","family":"Naumann","role":"aut","display":"Naumann, Jakob"},{"given":"Benjamin","display":"Ackermann, Benjamin","role":"aut","family":"Ackermann"},{"display":"Horn, Julian","family":"Horn","role":"aut","given":"Julian"},{"given":"Harald","family":"Latzel","role":"aut","display":"Latzel, Harald"},{"display":"Scheloske, Stefan","role":"aut","family":"Scheloske","given":"Stefan"},{"given":"Michael","display":"Galonska, Michael","role":"aut","family":"Galonska"}],"language":["eng"],"note":["Gesehen am 12.07.2017"],"name":{"displayForm":["Toke Printz Ringbæk, Stephan Brons, Jakob Naumann, Benjamin Ackermann, Julian Horn, Harald Latzel, Stefan Scheloske, Michael Galonska, Niels Bassler, Klemens Zink and Uli Weber"]},"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"15 January 2015"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"156078363X","id":{"doi":["10.1088/0031-9155/60/3/N59"],"eki":["156078363X"]}} 
SRT |a RINGBAEKTOFLUENCEINH1520