Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation: comparison with young healthy volunteers

To assess spatial and temporal pressure characteristics in patients with repaired aortic coarctation compared to young healthy volunteers using time-resolved velocity-encoded three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) and derived 4D pressure difference maps. After in v...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rengier, Fabian (VerfasserIn) , Eichhorn, Joachim (VerfasserIn) , Tengg-Kobligk, Hendrik von (VerfasserIn) , Ley-Zaporozhan, Julia (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Ley, Sebastian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 3 February 2015
In: The international journal of cardiovascular imaging
Year: 2015, Jahrgang: 31, Heft: 4, Pages: 823-830
ISSN:1875-8312
DOI:10.1007/s10554-015-0604-3
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1007/s10554-015-0604-3
Verlag, Volltext: https://link.springer.com/article/10.1007/s10554-015-0604-3
Volltext
Verfasserangaben:Fabian Rengier, Michael Delles, Joachim Eichhorn, Yoo-Jin Azad, Hendrik von Tengg-Kobligk, Julia Ley-Zaporozhan, Rüdiger Dillmann, Hans-Ulrich Kauczor, Roland Unterhinninghofen, Sebastian Ley

MARC

LEADER 00000caa a2200000 c 4500
001 1561071889
003 DE-627
005 20220813201233.0
007 cr uuu---uuuuu
008 170720s2015 xx |||||o 00| ||eng c
024 7 |a 10.1007/s10554-015-0604-3  |2 doi 
035 |a (DE-627)1561071889 
035 |a (DE-576)491071884 
035 |a (DE-599)BSZ491071884 
035 |a (OCoLC)1340977409 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rengier, Fabian  |d 1986-  |e VerfasserIn  |0 (DE-588)139065865  |0 (DE-627)608103284  |0 (DE-576)309935873  |4 aut 
245 1 0 |a Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation  |b comparison with young healthy volunteers  |c Fabian Rengier, Michael Delles, Joachim Eichhorn, Yoo-Jin Azad, Hendrik von Tengg-Kobligk, Julia Ley-Zaporozhan, Rüdiger Dillmann, Hans-Ulrich Kauczor, Roland Unterhinninghofen, Sebastian Ley 
264 1 |c 3 February 2015 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 20.07.2017 
520 |a To assess spatial and temporal pressure characteristics in patients with repaired aortic coarctation compared to young healthy volunteers using time-resolved velocity-encoded three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) and derived 4D pressure difference maps. After in vitro validation against invasive catheterization as gold standard, 4D flow MRI of the thoracic aorta was performed at 1.5T in 13 consecutive patients after aortic coarctation repair without recoarctation and 13 healthy volunteers. Using in-house developed processing software, 4D pressure difference maps were computed based on the Navier-Stokes equation. Pressure difference amplitudes, maximum slope of pressure amplitudes and spatial pressure range at mid systole were retrospectively measured by three readers, and twice by one reader to assess inter- and intraobserver agreement. In vitro, pressure differences derived from 4D flow MRI showed excellent agreement to invasive catheter measurements. In vivo, pressure difference amplitudes, maximum slope of pressure difference amplitudes and spatial pressure range at mid systole were significantly increased in patients compared to volunteers in the aortic arch, the proximal descending and the distal descending thoracic aorta (p < 0.05). Greatest differences occurred in the proximal descending aorta with values of the three parameters for patients versus volunteers being 19.7 ± 7.5 versus 10.0 ± 2.0 (p < 0.001), 10.9 ± 10.4 versus 1.9 ± 0.4 (p = 0.002), and 8.7 ± 6.3 versus 1.6 ± 0.9 (p < 0.001). Inter- and intraobserver agreements were excellent (p < 0.001). Noninvasive 4D pressure difference mapping derived from 4D flow MRI enables detection of altered intraluminal aortic pressures and showed significant spatial and temporal changes in patients with repaired aortic coarctation. 
700 1 |a Eichhorn, Joachim  |d 1971-  |e VerfasserIn  |0 (DE-588)121916545  |0 (DE-627)081618220  |0 (DE-576)292990960  |4 aut 
700 1 |a Tengg-Kobligk, Hendrik von  |d 1972-  |e VerfasserIn  |0 (DE-588)129455733  |0 (DE-627)397663188  |0 (DE-576)297668501  |4 aut 
700 1 |a Ley-Zaporozhan, Julia  |d 1978-  |e VerfasserIn  |0 (DE-588)12910468X  |0 (DE-627)389534633  |0 (DE-576)297496026  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Ley, Sebastian  |d 1974-  |e VerfasserIn  |0 (DE-588)123561256  |0 (DE-627)706346858  |0 (DE-576)293766835  |4 aut 
773 0 8 |i Enthalten in  |t The international journal of cardiovascular imaging  |d Dordrecht [u.a.] : Springer, 2001  |g 31(2015), 4, Seite 823-830  |h Online-Ressource  |w (DE-627)320474321  |w (DE-600)2008950-8  |w (DE-576)121190994  |x 1875-8312  |7 nnas  |a Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation comparison with young healthy volunteers 
773 1 8 |g volume:31  |g year:2015  |g number:4  |g pages:823-830  |g extent:8  |a Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation comparison with young healthy volunteers 
856 4 0 |u http://dx.doi.org/10.1007/s10554-015-0604-3  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://link.springer.com/article/10.1007/s10554-015-0604-3  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20170720 
993 |a Article 
994 |a 2015 
998 |g 123561256  |a Ley, Sebastian  |m 123561256:Ley, Sebastian  |p 10  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 12910468X  |a Ley-Zaporozhan, Julia  |m 12910468X:Ley-Zaporozhan, Julia  |d 910000  |d 911400  |e 910000PL12910468X  |e 911400PL12910468X  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 129455733  |a Tengg-Kobligk, Hendrik von  |m 129455733:Tengg-Kobligk, Hendrik von  |d 50000  |e 50000PT129455733  |k 0/50000/  |p 5 
998 |g 121916545  |a Eichhorn, Joachim  |m 121916545:Eichhorn, Joachim  |d 910000  |d 910500  |e 910000PE121916545  |e 910500PE121916545  |k 0/910000/  |k 1/910000/910500/  |p 3 
998 |g 139065865  |a Rengier, Fabian  |m 139065865:Rengier, Fabian  |d 910000  |d 911400  |e 910000PR139065865  |e 911400PR139065865  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1561071889  |e 2974617786 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Fabian Rengier, Michael Delles, Joachim Eichhorn, Yoo-Jin Azad, Hendrik von Tengg-Kobligk, Julia Ley-Zaporozhan, Rüdiger Dillmann, Hans-Ulrich Kauczor, Roland Unterhinninghofen, Sebastian Ley"]},"id":{"doi":["10.1007/s10554-015-0604-3"],"eki":["1561071889"]},"person":[{"display":"Rengier, Fabian","given":"Fabian","role":"aut","family":"Rengier"},{"display":"Eichhorn, Joachim","family":"Eichhorn","given":"Joachim","role":"aut"},{"family":"Tengg-Kobligk","role":"aut","given":"Hendrik von","display":"Tengg-Kobligk, Hendrik von"},{"display":"Ley-Zaporozhan, Julia","given":"Julia","role":"aut","family":"Ley-Zaporozhan"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","role":"aut","given":"Hans-Ulrich"},{"role":"aut","given":"Sebastian","family":"Ley","display":"Ley, Sebastian"}],"relHost":[{"origin":[{"publisher":"Springer","dateIssuedKey":"2001","publisherPlace":"Dordrecht [u.a.]","dateIssuedDisp":"2001-"}],"pubHistory":["Volume 17, issue 1 (February 2001)-"],"id":{"eki":["320474321"],"issn":["1875-8312"],"zdb":["2008950-8"]},"part":{"year":"2015","volume":"31","pages":"823-830","issue":"4","extent":"8","text":"31(2015), 4, Seite 823-830"},"title":[{"subtitle":"X-Ray imaging, echocardiography, nuclear cardiology and magnetic resonance","title":"The international journal of cardiovascular imaging","title_sort":"international journal of cardiovascular imaging"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 02.08.2023"],"recId":"320474321","physDesc":[{"extent":"Online-Ressource"}],"disp":"Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation comparison with young healthy volunteersThe international journal of cardiovascular imaging"}],"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"3 February 2015"}],"title":[{"subtitle":"comparison with young healthy volunteers","title_sort":"Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation","title":"Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation"}],"note":["Gesehen am 20.07.2017"],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1561071889","physDesc":[{"extent":"8 S."}]} 
SRT |a RENGIERFABNONINVASIV3201