Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the medtronic corevalve system

The aim of the CoreValve prospective, international, post-market ADVANCE-II study was to define the rates of conduction disturbances and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement with the Medtronic CoreValve System (Minneapolis, Minnesota) using optimized im...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Petronio, Anna Sonia (VerfasserIn) , Bekeredjian, Raffi (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 18 May 2015
In: JACC Cardiovascular interventions
Year: 2015, Jahrgang: 8, Heft: 6, Pages: 837-846$10
ISSN:1876-7605
DOI:10.1016/j.jcin.2015.02.005
Online-Zugang:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1016/j.jcin.2015.02.005
Verlag, kostenfrei, Volltext: http://www.sciencedirect.com/science/article/pii/S1936879815002514
Volltext
Verfasserangaben:Anna S. Petronio, MD, Jan-Malte Sinning, MD, Nicolas Van Mieghem, MD, Giulio Zucchelli, MD, PhD, Georg Nickenig, MD, Raffi Bekeredjian, MD, PhD, Johan Bosmans, MD, PhD, Francesco Bedogni, MD, Marian Branny, MD, Karl Stangl, MD, Jan Kovac, MD, Molly Schiltgen, MS, Stacia Kraus, MPH, Peter de Jaegere, MD,PhD

MARC

LEADER 00000caa a2200000 c 4500
001 1562336584
003 DE-627
005 20250206093958.0
007 cr uuu---uuuuu
008 170810s2015 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jcin.2015.02.005  |2 doi 
035 |a (DE-627)1562336584 
035 |a (DE-576)49233658X 
035 |a (DE-599)BSZ49233658X 
035 |a (OCoLC)1340978453 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Petronio, Anna Sonia  |e VerfasserIn  |0 (DE-588)1138058726  |0 (DE-627)895428911  |0 (DE-576)49233577X  |4 aut 
245 1 0 |a Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the medtronic corevalve system  |c Anna S. Petronio, MD, Jan-Malte Sinning, MD, Nicolas Van Mieghem, MD, Giulio Zucchelli, MD, PhD, Georg Nickenig, MD, Raffi Bekeredjian, MD, PhD, Johan Bosmans, MD, PhD, Francesco Bedogni, MD, Marian Branny, MD, Karl Stangl, MD, Jan Kovac, MD, Molly Schiltgen, MS, Stacia Kraus, MPH, Peter de Jaegere, MD,PhD 
264 1 |c 18 May 2015 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 10.08.2017 
520 |a The aim of the CoreValve prospective, international, post-market ADVANCE-II study was to define the rates of conduction disturbances and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement with the Medtronic CoreValve System (Minneapolis, Minnesota) using optimized implantation techniques and application of international guidelines on cardiac pacing. Conduction disturbances are a frequent complication of transcatheter aortic valve replacement. The rates of PPI in the published reports vary according to bioprosthesis type and the indications for PPI. The primary endpoint was the 30-day incidence of PPI with Class I/II indications when the Medtronic CoreValve System was implanted at an optimal depth (≤6 mm below the aortic annulus). The timing and resolution of all new-onset conduction disturbances were analyzed. A total of 194 patients were treated. The overall rate of PPI for Class I/II indications was 18.2%. An optimal depth was reached in 43.2% of patients, with a nonsignificantly lower incidence of PPI in patients with depths ≤6 mm, compared with those with deeper implants (13.3% vs. 21.1%; p = 0.14). In a paired analysis, new-onset left bundle branch block and first-degree atrioventricular block occurred in 45.4% and 39.0% of patients, respectively, and resolved spontaneously within 30 days in 43.2% and 73.9%, respectively. In patients with new PPI, the rate of intrinsic sinus rhythm increased from 25.9% at 7 days to 59.3% at 30 days (p = 0.004). Optimal Medtronic CoreValve System deployment and adherence to international guidelines on cardiac pacing are associated with a lower rate of new PPI after transcatheter aortic valve replacement, compared with results reported in previous studies. (CoreValve Advance-II Study: Prospective International Post-Market Study [ADVANCE II]; NCT01624870) 
650 4 |a aortic stenosis 
650 4 |a conduction disturbance 
650 4 |a permanent pacemaker implantation 
650 4 |a transcatheter aortic valve replacement 
700 1 |a Bekeredjian, Raffi  |d 1972-  |e VerfasserIn  |0 (DE-588)122088271  |0 (DE-627)705767930  |0 (DE-576)293085781  |4 aut 
773 0 8 |i Enthalten in  |a American College of Cardiology  |t JACC Cardiovascular interventions  |d New York, NY : Elsevier, 2008  |g 8(2015), 6, Seite 837-846$10  |h Online-Ressource  |w (DE-627)578539160  |w (DE-600)2452163-2  |w (DE-576)294403027  |x 1876-7605  |7 nnas 
773 1 8 |g volume:8  |g year:2015  |g number:6  |g pages:837-846$10  |a Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the medtronic corevalve system 
856 4 0 |u http://dx.doi.org/10.1016/j.jcin.2015.02.005  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1936879815002514  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20170810 
993 |a Article 
994 |a 2015 
998 |g 122088271  |a Bekeredjian, Raffi  |m 122088271:Bekeredjian, Raffi  |d 910000  |d 910100  |e 910000PB122088271  |e 910100PB122088271  |k 0/910000/  |k 1/910000/910100/  |p 6 
999 |a KXP-PPN1562336584  |e 2977342451 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 10.08.2017"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"relHost":[{"title":[{"title_sort":"JACC Cardiovascular interventions","subtitle":"a journal of the American College of Cardiology","title":"JACC Cardiovascular interventions"}],"part":{"volume":"8","text":"8(2015), 6, Seite 837-846$10","issue":"6","pages":"837-846$10","year":"2015"},"pubHistory":["1.2008 -"],"recId":"578539160","corporate":[{"roleDisplay":"VerfasserIn","display":"American College of Cardiology","role":"aut"}],"language":["eng"],"disp":"American College of CardiologyJACC Cardiovascular interventions","note":["Gesehen am 05.06.23","Fortsetzung der Druck-Ausgabe"],"type":{"media":"Online-Ressource","bibl":"periodical"},"id":{"issn":["1876-7605"],"zdb":["2452163-2"],"eki":["578539160"]},"origin":[{"dateIssuedDisp":"2008-","publisher":"Elsevier ; American College of Cardiology","dateIssuedKey":"2008","publisherPlace":"New York, NY ; New York, NY"}],"physDesc":[{"extent":"Online-Ressource"}]}],"language":["eng"],"recId":"1562336584","origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"18 May 2015"}],"title":[{"title":"Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the medtronic corevalve system","title_sort":"Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the medtronic corevalve system"}],"id":{"doi":["10.1016/j.jcin.2015.02.005"],"eki":["1562336584"]},"name":{"displayForm":["Anna S. Petronio, MD, Jan-Malte Sinning, MD, Nicolas Van Mieghem, MD, Giulio Zucchelli, MD, PhD, Georg Nickenig, MD, Raffi Bekeredjian, MD, PhD, Johan Bosmans, MD, PhD, Francesco Bedogni, MD, Marian Branny, MD, Karl Stangl, MD, Jan Kovac, MD, Molly Schiltgen, MS, Stacia Kraus, MPH, Peter de Jaegere, MD,PhD"]},"person":[{"roleDisplay":"VerfasserIn","display":"Petronio, Anna Sonia","role":"aut","family":"Petronio","given":"Anna Sonia"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Bekeredjian, Raffi","given":"Raffi","family":"Bekeredjian"}]} 
SRT |a PETRONIOANOPTIMALIMP1820