Associations of macular thickness in spectral-domain OCT with ocular and systemic cardiovascular parameters: the MIPH Eye and Health Study

Purpose: Beyond in-vivo histological analysis of retinal tissue, optical coherence tomography (OCT) allows quantitative image analysis. This study evaluates associations of macular retinal thickness measured with spectral-domain OCT (SD-OCT) and ocular and systemic cardiovascular parameters in adult...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schuster, Alexander K. (VerfasserIn) , Fischer, Joachim E. (VerfasserIn) , Voßmerbäumer, Urs (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2015
In: Graefe's archive for clinical and experimental ophthalmology
Year: 2015, Jahrgang: 253, Heft: 1, Pages: 121-125
ISSN:1435-702X
DOI:10.1007/s00417-014-2781-5
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1007/s00417-014-2781-5
Verlag, Volltext: https://link-springer-com.ezproxy.medma.uni-heidelberg.de/article/10.1007/s00417-014-2781-5
Volltext
Verfasserangaben:Alexander Karl-Georg Schuster, Joachim Ernst Fischer, Urs Vossmerbaeumer

MARC

LEADER 00000caa a2200000 c 4500
001 1563269899
003 DE-627
005 20241209145735.0
007 cr uuu---uuuuu
008 170906s2015 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00417-014-2781-5  |2 doi 
035 |a (DE-627)1563269899 
035 |a (DE-576)493269894 
035 |a (DE-599)BSZ493269894 
035 |a (OCoLC)1340979120 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schuster, Alexander K.  |d 1985-  |e VerfasserIn  |0 (DE-588)1049518810  |0 (DE-627)782185789  |0 (DE-576)403510139  |4 aut 
245 1 0 |a Associations of macular thickness in spectral-domain OCT with ocular and systemic cardiovascular parameters  |b the MIPH Eye and Health Study  |c Alexander Karl-Georg Schuster, Joachim Ernst Fischer, Urs Vossmerbaeumer 
264 1 |c 2015 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 26. September 2014 
500 |a Gesehen am 06.09.2017 
520 |a Purpose: Beyond in-vivo histological analysis of retinal tissue, optical coherence tomography (OCT) allows quantitative image analysis. This study evaluates associations of macular retinal thickness measured with spectral-domain OCT (SD-OCT) and ocular and systemic cardiovascular parameters in adult subjects. Methods: An epidemiological cross-sectional study was performed in the staff of a European high-tech company. Examination of known cardiovascular risk factors including biochemical blood analysis was performed, and ocular parameters such as refraction, tonometry, SD-OCT imaging of the macula and cornea, and fundus photography were evaluated. Retinal thickness measurements were evaluated according to the ETDRS grid. Associations of macular retinal thickness and systemic cardiovascular and ocular parameters were calculated by multivariate analysis using SPSS software. Results: Four hundred and twenty-four probands were included. Macular thickness measurement were significantly associated with gender and refraction. Female persons had thinner retinal thickness in all zones. Macular thickness decreased with increasing myopia in all perifoveal measurements. Outer perifoveal measurements were associated with keratometry; a flatter corneal radius was linked to a thinner retina. Tonometry and systemic cardiovascular risk factors were not associated with macular retinal thickness in multivariate analysis (p > 0.05). Conclusions: Macular retinal thickness is associated with refraction and gender; cardiovascular risk factors or tonometry do not influence macular retinal thickness measurements. Keratometry might influence outer zone measurements. Our findings provide a dataset for quantitative evaluation of SD-OCT, and evaluate influencing factors. 
700 1 |a Fischer, Joachim E.  |d 1957-  |e VerfasserIn  |0 (DE-588)1029135800  |0 (DE-627)732480620  |0 (DE-576)37658775X  |4 aut 
700 1 |a Voßmerbäumer, Urs  |d 1973-  |e VerfasserIn  |0 (DE-588)121535819  |0 (DE-627)705518868  |0 (DE-576)292759541  |4 aut 
773 0 8 |i Enthalten in  |t Graefe's archive for clinical and experimental ophthalmology  |d Berlin : Springer, 1982  |g 253(2015), 1, Seite 121-125  |h Online-Ressource  |w (DE-627)253723728  |w (DE-600)1459159-5  |w (DE-576)072372931  |x 1435-702X  |7 nnas  |a Associations of macular thickness in spectral-domain OCT with ocular and systemic cardiovascular parameters the MIPH Eye and Health Study 
773 1 8 |g volume:253  |g year:2015  |g number:1  |g pages:121-125  |g extent:5  |a Associations of macular thickness in spectral-domain OCT with ocular and systemic cardiovascular parameters the MIPH Eye and Health Study 
856 4 0 |u http://dx.doi.org/10.1007/s00417-014-2781-5  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://link-springer-com.ezproxy.medma.uni-heidelberg.de/article/10.1007/s00417-014-2781-5  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20170906 
993 |a Article 
994 |a 2015 
998 |g 121535819  |a Voßmerbäumer, Urs  |m 121535819:Voßmerbäumer, Urs  |d 60000  |d 65300  |e 60000PV121535819  |e 65300PV121535819  |k 0/60000/  |k 1/60000/65300/  |p 3  |y j 
998 |g 1029135800  |a Fischer, Joachim E.  |m 1029135800:Fischer, Joachim E.  |d 60000  |d 65300  |e 60000PF1029135800  |e 65300PF1029135800  |k 0/60000/  |k 1/60000/65300/  |p 2 
999 |a KXP-PPN1563269899  |e 2979754269 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"given":"Alexander K.","role":"aut","family":"Schuster","display":"Schuster, Alexander K."},{"role":"aut","given":"Joachim E.","display":"Fischer, Joachim E.","family":"Fischer"},{"display":"Voßmerbäumer, Urs","family":"Voßmerbäumer","given":"Urs","role":"aut"}],"language":["eng"],"title":[{"title_sort":"Associations of macular thickness in spectral-domain OCT with ocular and systemic cardiovascular parameters","subtitle":"the MIPH Eye and Health Study","title":"Associations of macular thickness in spectral-domain OCT with ocular and systemic cardiovascular parameters"}],"origin":[{"dateIssuedDisp":"2015","dateIssuedKey":"2015"}],"note":["Online veröffentlicht: 26. September 2014","Gesehen am 06.09.2017"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"5 S."}],"name":{"displayForm":["Alexander Karl-Georg Schuster, Joachim Ernst Fischer, Urs Vossmerbaeumer"]},"recId":"1563269899","relHost":[{"titleAlt":[{"title":"Archive for clinical and experimental ophthalmology"}],"part":{"extent":"5","volume":"253","issue":"1","text":"253(2015), 1, Seite 121-125","pages":"121-125","year":"2015"},"language":["eng"],"id":{"zdb":["1459159-5"],"issn":["1435-702X"],"eki":["253723728"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"253723728","disp":"Associations of macular thickness in spectral-domain OCT with ocular and systemic cardiovascular parameters the MIPH Eye and Health StudyGraefe's archive for clinical and experimental ophthalmology","type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["Volume 218, issue 1 (January 1982)-"],"note":["Gesehen am 07.04.2025","Ungezählte Beil.: Supplement"],"origin":[{"dateIssuedKey":"1982","publisher":"Springer ; Springer","dateIssuedDisp":"1982-","publisherPlace":"Berlin ; Heidelberg ; Berlin ; Heidelberg ; New York, NY"}],"title":[{"title":"Graefe's archive for clinical and experimental ophthalmology","title_sort":"Graefe's archive for clinical and experimental ophthalmology","subtitle":"official organ of the Club Jules Gonin"}]}],"id":{"doi":["10.1007/s00417-014-2781-5"],"eki":["1563269899"]}} 
SRT |a SCHUSTERALASSOCIATIO2015