Technical prerequisites and imaging protocols for CT perfusion imaging in oncology
The aim of this review article is to define the technical prerequisites of modern state-of-the-art CT perfusion imaging in oncology at reasonable dose levels. The focus is mainly on abdominal and thoracic tumor imaging, as they pose the largest challenges with respect to attenuation and patient moti...
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
December 2015
|
| In: |
European journal of radiology
Year: 2015, Jahrgang: 84, Heft: 12, Pages: 2359-2367 |
| ISSN: | 1872-7727 |
| DOI: | 10.1016/j.ejrad.2015.06.010 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.ejrad.2015.06.010 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X15300176 |
| Verfasserangaben: | Ernst Klotz, Ulrike Haberland, Gerhard Glatting, Stefan O. Schoenberg, Christian Fink, Ulrike Attenberger, Thomas Henzler |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1563911523 | ||
| 003 | DE-627 | ||
| 005 | 20220813232802.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 170928s2015 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejrad.2015.06.010 |2 doi | |
| 035 | |a (DE-627)1563911523 | ||
| 035 | |a (DE-576)493911529 | ||
| 035 | |a (DE-599)BSZ493911529 | ||
| 035 | |a (OCoLC)1340979445 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Klotz, Ernst |e VerfasserIn |0 (DE-588)1140609521 |0 (DE-627)898600936 |0 (DE-576)493911421 |4 aut | |
| 245 | 1 | 0 | |a Technical prerequisites and imaging protocols for CT perfusion imaging in oncology |c Ernst Klotz, Ulrike Haberland, Gerhard Glatting, Stefan O. Schoenberg, Christian Fink, Ulrike Attenberger, Thomas Henzler |
| 264 | 1 | |c December 2015 | |
| 300 | |a 9 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 28.09.2017 | ||
| 520 | |a The aim of this review article is to define the technical prerequisites of modern state-of-the-art CT perfusion imaging in oncology at reasonable dose levels. The focus is mainly on abdominal and thoracic tumor imaging, as they pose the largest challenges with respect to attenuation and patient motion. We will show that low kV dynamic scanning in conjunction with detection technology optimized for low photon fluxes has the highest impact on reducing dose independently of other choices made in the protocol selection. We discuss, derived from relatively simple first principles, on what appropriate temporal sampling and total scan duration depend on and why optimized contrast medium injection protocols are also essential in limiting dose. Finally we will examine the possibility of simultaneously extracting standard morphological and functional information from one single 4D examination as a potential enabler for a more widespread use of dynamic contrast enhanced CT in oncology. | ||
| 650 | 4 | |a Dynamic contrast enhanced computed tomography | |
| 650 | 4 | |a Functional imaging | |
| 650 | 4 | |a Oncology | |
| 650 | 4 | |a Perfusion CT | |
| 700 | 1 | |a Glatting, Gerhard |d 1961- |e VerfasserIn |0 (DE-588)1055963103 |0 (DE-627)792987675 |0 (DE-576)411974521 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Attenberger, Ulrike |d 1980- |e VerfasserIn |0 (DE-588)131554859 |0 (DE-627)510698557 |0 (DE-576)298582775 |4 aut | |
| 700 | 1 | |a Henzler, Thomas |d 1980- |e VerfasserIn |0 (DE-588)134001486 |0 (DE-627)559468415 |0 (DE-576)276829948 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European journal of radiology |d Amsterdam [u.a.] : Elsevier Science, 1990 |g 84(2015), 12, Seite 2359-2367 |h Online-Ressource |w (DE-627)32044483X |w (DE-600)2005350-2 |w (DE-576)099718138 |x 1872-7727 |7 nnas |a Technical prerequisites and imaging protocols for CT perfusion imaging in oncology |
| 773 | 1 | 8 | |g volume:84 |g year:2015 |g number:12 |g pages:2359-2367 |g extent:9 |a Technical prerequisites and imaging protocols for CT perfusion imaging in oncology |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.ejrad.2015.06.010 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0720048X15300176 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20170928 | ||
| 993 | |a Article | ||
| 994 | |a 2015 | ||
| 998 | |g 134001486 |a Henzler, Thomas |m 134001486:Henzler, Thomas |d 60000 |e 60000PH134001486 |k 0/60000/ |p 7 |y j | ||
| 998 | |g 131554859 |a Attenberger, Ulrike |m 131554859:Attenberger, Ulrike |d 60000 |d 62900 |e 60000PA131554859 |e 62900PA131554859 |k 0/60000/ |k 1/60000/62900/ |p 6 | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 4 | ||
| 998 | |g 1055963103 |a Glatting, Gerhard |m 1055963103:Glatting, Gerhard |d 60000 |d 63000 |e 60000PG1055963103 |e 63000PG1055963103 |k 0/60000/ |k 1/60000/63000/ |p 3 | ||
| 999 | |a KXP-PPN1563911523 |e 2981981080 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"extent":"9 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1563911523"],"doi":["10.1016/j.ejrad.2015.06.010"]},"relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["Nachgewiesen 10.1990 -"],"recId":"32044483X","disp":"Technical prerequisites and imaging protocols for CT perfusion imaging in oncologyEuropean journal of radiology","language":["eng"],"titleAlt":[{"title":"EJR"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"pages":"2359-2367","year":"2015","text":"84(2015), 12, Seite 2359-2367","volume":"84","issue":"12","extent":"9"},"id":{"zdb":["2005350-2"],"issn":["1872-7727"],"eki":["32044483X"]},"note":["Gesehen am 05.02.20"],"origin":[{"dateIssuedKey":"1990","publisherPlace":"Amsterdam [u.a.]","publisher":"Elsevier Science","dateIssuedDisp":"1990-"}],"title":[{"title":"European journal of radiology","title_sort":"European journal of radiology","subtitle":"EJR"}]}],"note":["Gesehen am 28.09.2017"],"person":[{"role":"aut","family":"Klotz","given":"Ernst","display":"Klotz, Ernst"},{"role":"aut","given":"Gerhard","display":"Glatting, Gerhard","family":"Glatting"},{"given":"Stefan","display":"Schönberg, Stefan","family":"Schönberg","role":"aut"},{"role":"aut","family":"Attenberger","display":"Attenberger, Ulrike","given":"Ulrike"},{"role":"aut","family":"Henzler","display":"Henzler, Thomas","given":"Thomas"}],"recId":"1563911523","name":{"displayForm":["Ernst Klotz, Ulrike Haberland, Gerhard Glatting, Stefan O. Schoenberg, Christian Fink, Ulrike Attenberger, Thomas Henzler"]},"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"December 2015"}],"language":["eng"],"title":[{"title":"Technical prerequisites and imaging protocols for CT perfusion imaging in oncology","title_sort":"Technical prerequisites and imaging protocols for CT perfusion imaging in oncology"}]} | ||
| SRT | |a KLOTZERNSTTECHNICALP2015 | ||