The dream of a one-stop-shop: meta-analysis on myocardial perfusion CT

To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography (SPECT), a...

Full description

Saved in:
Bibliographic Details
Main Authors: Pelgrim, Gert Jan (Author) , Henzler, Thomas (Author)
Format: Article (Journal)
Language:English
Published: December 2015
In: European journal of radiology
Year: 2015, Volume: 84, Issue: 12, Pages: 2411-2420
ISSN:1872-7727
DOI:10.1016/j.ejrad.2014.12.032
Online Access:Verlag, Volltext: http://dx.doi.org/10.1016/j.ejrad.2014.12.032
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X15000212
Get full text
Author Notes:Gert Jan Pelgrim, Monique Dorrius, Xueqian Xie, Martijn A. M. den Dekker, U. Joseph Schoepf, Thomas Henzler, Matthijs Oudkerk, Rozemarijn Vliegenthart

MARC

LEADER 00000caa a2200000 c 4500
001 1564566099
003 DE-627
005 20230427142056.0
007 cr uuu---uuuuu
008 171019s2015 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.ejrad.2014.12.032  |2 doi 
035 |a (DE-627)1564566099 
035 |a (DE-576)494566094 
035 |a (DE-599)BSZ494566094 
035 |a (OCoLC)1340980833 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Pelgrim, Gert Jan  |e VerfasserIn  |0 (DE-588)1141919559  |0 (DE-627)1000917967  |0 (DE-576)494565721  |4 aut 
245 1 4 |a The dream of a one-stop-shop  |b meta-analysis on myocardial perfusion CT  |c Gert Jan Pelgrim, Monique Dorrius, Xueqian Xie, Martijn A. M. den Dekker, U. Joseph Schoepf, Thomas Henzler, Matthijs Oudkerk, Rozemarijn Vliegenthart 
264 1 |c December 2015 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.10.2017 
520 |a To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography (SPECT), and magnetic resonance imaging (MRI). PubMed, Web of Knowledge and Embase were searched from January 1, 1998 until July 1, 2014. The search yielded 9475 articles. After duplicate removal, 6041 were screened on title and abstract. The resulting 276 articles were independently analyzed in full-text by two reviewers, and included if the inclusion criteria were met. The articles reporting diagnostic parameters including true positive, true negative, false positive and false negative were subsequently evaluated for the meta-analysis. Results were pooled according to CT perfusion technique, namely snapshot techniques: single-phase rest, single-phase stress, single-phase dual-energy stress and combined coronary CT angiography [rest] and single-phase stress, as well the dynamic technique: dynamic stress CT perfusion. Twenty-two articles were included in the meta-analysis (1507 subjects). Pooled per-patient sensitivity and specificity of single-phase rest CT compared to rest SPECT were 89% (95% confidence interval [CI], 82-94%) and 88% (95% CI, 78-94%), respectively. Vessel-based sensitivity and specificity of single-phase stress CT compared to ICA-based >70% stenosis were 82% (95% CI, 64-92%) and 78% (95% CI, 61-89%). Segment-based sensitivity and specificity of single-phase dual-energy stress CT in comparison to stress MRI were 75% (95% CI, 60-85%) and 95% (95% CI, 80-99%). Segment-based sensitivity and specificity of dynamic stress CT perfusion compared to stress SPECT were 77% (95% CI, 67-85) and 89% (95% CI, 78-95%). For combined coronary CT angiography and single-phase stress CT, vessel-based sensitivity and specificity in comparison to ICA-based >50% stenosis were 84% (95% CI, 67-93%) and 93% (95% CI, 89-96%). This meta-analysis shows considerable variation in techniques and reference standards for CT of myocardial blood supply. While CT seems sensitive and specific for evaluation of hemodynamically relevant CAD, studies so far are limited in size. Standardization of myocardial perfusion CT technique is essential. 
650 4 |a Cardiac 
650 4 |a CT perfusion 
650 4 |a Dual-energy 
650 4 |a Meta-analysis 
650 4 |a Stress CT 
700 1 |a Henzler, Thomas  |d 1980-  |e VerfasserIn  |0 (DE-588)134001486  |0 (DE-627)559468415  |0 (DE-576)276829948  |4 aut 
773 0 8 |i Enthalten in  |t European journal of radiology  |d Amsterdam [u.a.] : Elsevier Science, 1990  |g 84(2015), 12, Seite 2411-2420  |h Online-Ressource  |w (DE-627)32044483X  |w (DE-600)2005350-2  |w (DE-576)099718138  |x 1872-7727  |7 nnas  |a The dream of a one-stop-shop meta-analysis on myocardial perfusion CT 
773 1 8 |g volume:84  |g year:2015  |g number:12  |g pages:2411-2420  |g extent:10  |a The dream of a one-stop-shop meta-analysis on myocardial perfusion CT 
856 4 0 |u http://dx.doi.org/10.1016/j.ejrad.2014.12.032  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S0720048X15000212  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20171019 
993 |a Article 
994 |a 2015 
998 |g 134001486  |a Henzler, Thomas  |m 134001486:Henzler, Thomas  |d 60000  |e 60000PH134001486  |k 0/60000/  |p 6 
999 |a KXP-PPN1564566099  |e 2984649036 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"title":[{"subtitle":"meta-analysis on myocardial perfusion CT","title_sort":"dream of a one-stop-shop","title":"The dream of a one-stop-shop"}],"recId":"1564566099","origin":[{"dateIssuedDisp":"December 2015","dateIssuedKey":"2015"}],"name":{"displayForm":["Gert Jan Pelgrim, Monique Dorrius, Xueqian Xie, Martijn A. M. den Dekker, U. Joseph Schoepf, Thomas Henzler, Matthijs Oudkerk, Rozemarijn Vliegenthart"]},"person":[{"family":"Pelgrim","display":"Pelgrim, Gert Jan","given":"Gert Jan","role":"aut"},{"family":"Henzler","given":"Thomas","display":"Henzler, Thomas","role":"aut"}],"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["Nachgewiesen 10.1990 -"],"language":["eng"],"titleAlt":[{"title":"EJR"}],"disp":"The dream of a one-stop-shop meta-analysis on myocardial perfusion CTEuropean journal of radiology","recId":"32044483X","note":["Gesehen am 05.02.20"],"physDesc":[{"extent":"Online-Ressource"}],"part":{"pages":"2411-2420","year":"2015","text":"84(2015), 12, Seite 2411-2420","volume":"84","issue":"12","extent":"10"},"id":{"eki":["32044483X"],"issn":["1872-7727"],"zdb":["2005350-2"]},"title":[{"title":"European journal of radiology","subtitle":"EJR","title_sort":"European journal of radiology"}],"origin":[{"publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1990","dateIssuedDisp":"1990-","publisher":"Elsevier Science"}]}],"note":["Gesehen am 19.10.2017"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1564566099"],"doi":["10.1016/j.ejrad.2014.12.032"]},"physDesc":[{"extent":"10 S."}]} 
SRT |a PELGRIMGERDREAMOFAON2015