In vivo micro-CT imaging of untreated and irradiated orthotopic glioblastoma xenografts in mice: capabilities, limitations and a comparison with bioluminescence imaging

Small animal imaging is of increasing relevance in biomedical research. Studies systematically assessing the diagnostic accuracy of contrast-enhanced in vivo micro-CT of orthotopic glioma xenografts in mice do not exist. NOD/SCID/γc−/− mice (n = 27) underwent intracerebral implantation of 2.5 × 106...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kirschner, Stefanie (VerfasserIn) , Hartmann, Linda (VerfasserIn) , Bierbaum, Miriam (VerfasserIn) , Maros, Máté E. (VerfasserIn) , Kerl, Hans Ulrich (VerfasserIn) , Wenz, Frederik (VerfasserIn) , Glatting, Gerhard (VerfasserIn) , Giordano, Frank Anton (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 22 January 2015
In: Journal of neuro-oncology
Year: 2015, Jahrgang: 122, Heft: 2, Pages: 245-254
ISSN:1573-7373
DOI:10.1007/s11060-014-1708-7
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1007/s11060-014-1708-7
Verlag, Volltext: https://link-springer-com.ezproxy.medma.uni-heidelberg.de/article/10.1007/s11060-014-1708-7
Volltext
Verfasserangaben:Stefanie Kirschner, Manuela C. Felix, Linda Hartmann, Miriam Bierbaum, Máté E. Maros, Hans U. Kerl, Frederik Wenz, Gerhard Glatting, Martin Kramer, Frank A. Giordano, Marc A. Brockmann

MARC

LEADER 00000caa a2200000 c 4500
001 1565366271
003 DE-627
005 20220814022558.0
007 cr uuu---uuuuu
008 171115s2015 xx |||||o 00| ||eng c
024 7 |a 10.1007/s11060-014-1708-7  |2 doi 
035 |a (DE-627)1565366271 
035 |a (DE-576)495366277 
035 |a (DE-599)BSZ495366277 
035 |a (OCoLC)1340982143 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kirschner, Stefanie  |d 1980-  |e VerfasserIn  |0 (DE-588)1075006708  |0 (DE-627)832847429  |0 (DE-576)443195234  |4 aut 
245 1 0 |a In vivo micro-CT imaging of untreated and irradiated orthotopic glioblastoma xenografts in mice  |b capabilities, limitations and a comparison with bioluminescence imaging  |c Stefanie Kirschner, Manuela C. Felix, Linda Hartmann, Miriam Bierbaum, Máté E. Maros, Hans U. Kerl, Frederik Wenz, Gerhard Glatting, Martin Kramer, Frank A. Giordano, Marc A. Brockmann 
264 1 |c 22 January 2015 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 15.11.2017 
520 |a Small animal imaging is of increasing relevance in biomedical research. Studies systematically assessing the diagnostic accuracy of contrast-enhanced in vivo micro-CT of orthotopic glioma xenografts in mice do not exist. NOD/SCID/γc−/− mice (n = 27) underwent intracerebral implantation of 2.5 × 106 GFP-Luciferase-transduced U87MG cells. Mice underwent bioluminescence imaging (BLI) to detect tumor growth and afterwards repeated contrast-enhanced (300 µl Iomeprol i.v.) micro-CT imaging (80 kV, 75 µAs, 360° rotation, 1,000 projections, 33 s scan time, resolution 40 × 40 × 53 µm, 0.5 Gy/scan). Presence of tumors, tumor diameter and tumor volume in micro-CT were rated by two independent readers. Results were compared with histological analyses. Six mice with tumors confirmed by micro-CT received fractionated irradiation (3 × 5 Gy every other day) using the micro-CT (5 mm pencil beam geometry). Repeated micro-CT scans were tolerated well. Tumor engraftment rate was 74 % (n = 20). In micro-CT, mean tumor volume was 30 ± 33 mm3, and the smallest detectable tumor measured 360 × 620 µm. The inter-rater agreement (n = 51 micro-CT scans) for the item tumor yes/no was excellent (Spearman-Rho = 0.862, p < 0.001). Sensitivity and specificity of micro-CT were 0.95 and 0.71, respectively (PPV = 0.91, NPV = 0.83). BLI on day 21 after tumor implantation had a sensitivity and specificity of 0.90 and 1.0, respectively (PPV = 1.0, NPV = 0.5). Maximum tumor diameter and volume in micro-CT and histology correlated excellently (tumor diameter: 0.929, p < 0.001; tumor volume: 0.969, p < 0.001, n = 17). Irradiated animals showed a large central tumor necrosis. Longitudinal contrast enhanced micro-CT imaging of brain tumor growth in live mice is feasible at high sensitivity levels and with excellent inter-rater agreement and allows visualization of radiation effects. 
700 1 |a Hartmann, Linda  |e VerfasserIn  |0 (DE-588)1033514756  |0 (DE-627)741332558  |0 (DE-576)381120325  |4 aut 
700 1 |a Bierbaum, Miriam  |d 1978-  |e VerfasserIn  |0 (DE-588)1144378818  |0 (DE-627)1004714599  |0 (DE-576)495364274  |4 aut 
700 1 |a Maros, Máté E.  |d 1986-  |e VerfasserIn  |0 (DE-588)1144379407  |0 (DE-627)1004715153  |0 (DE-576)495364827  |4 aut 
700 1 |a Kerl, Hans Ulrich  |d 1977-  |e VerfasserIn  |0 (DE-588)130070742  |0 (DE-627)489616216  |0 (DE-576)297980823  |4 aut 
700 1 |a Wenz, Frederik  |d 1966-  |e VerfasserIn  |0 (DE-588)113310390  |0 (DE-627)663837766  |0 (DE-576)346656281  |4 aut 
700 1 |a Glatting, Gerhard  |d 1961-  |e VerfasserIn  |0 (DE-588)1055963103  |0 (DE-627)792987675  |0 (DE-576)411974521  |4 aut 
700 1 |a Giordano, Frank Anton  |d 1980-  |e VerfasserIn  |0 (DE-588)136378455  |0 (DE-627)694333093  |0 (DE-576)300990529  |4 aut 
773 0 8 |i Enthalten in  |t Journal of neuro-oncology  |d Dordrecht [u.a.] : Springer Science + Business Media B.V, 1983  |g 122(2015), 2, Seite 245-254  |h Online-Ressource  |w (DE-627)32046122X  |w (DE-600)2007293-4  |w (DE-576)107058944  |x 1573-7373  |7 nnas  |a In vivo micro-CT imaging of untreated and irradiated orthotopic glioblastoma xenografts in mice capabilities, limitations and a comparison with bioluminescence imaging 
773 1 8 |g volume:122  |g year:2015  |g number:2  |g pages:245-254  |g extent:10  |a In vivo micro-CT imaging of untreated and irradiated orthotopic glioblastoma xenografts in mice capabilities, limitations and a comparison with bioluminescence imaging 
856 4 0 |u http://dx.doi.org/10.1007/s11060-014-1708-7  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://link-springer-com.ezproxy.medma.uni-heidelberg.de/article/10.1007/s11060-014-1708-7  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20171115 
993 |a Article 
994 |a 2015 
998 |g 136378455  |a Giordano, Frank Anton  |m 136378455:Giordano, Frank Anton  |d 60000  |d 63000  |e 60000PG136378455  |e 63000PG136378455  |k 0/60000/  |k 1/60000/63000/  |p 10 
998 |g 1055963103  |a Glatting, Gerhard  |m 1055963103:Glatting, Gerhard  |d 60000  |d 63000  |e 60000PG1055963103  |e 63000PG1055963103  |k 0/60000/  |k 1/60000/63000/  |p 8 
998 |g 113310390  |a Wenz, Frederik  |m 113310390:Wenz, Frederik  |d 60000  |d 63000  |e 60000PW113310390  |e 63000PW113310390  |k 0/60000/  |k 1/60000/63000/  |p 7 
998 |g 130070742  |a Kerl, Hans Ulrich  |m 130070742:Kerl, Hans Ulrich  |d 60000  |d 63000  |e 60000PK130070742  |e 63000PK130070742  |k 0/60000/  |k 1/60000/63000/  |p 6 
998 |g 1144379407  |a Maros, Máté E.  |m 1144379407:Maros, Máté E.  |d 60000  |d 63000  |e 60000PM1144379407  |e 63000PM1144379407  |k 0/60000/  |k 1/60000/63000/  |p 5 
998 |g 1144378818  |a Bierbaum, Miriam  |m 1144378818:Bierbaum, Miriam  |d 60000  |d 63000  |e 60000PB1144378818  |e 63000PB1144378818  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 1033514756  |a Hartmann, Linda  |m 1033514756:Hartmann, Linda  |d 60000  |d 63000  |e 60000PH1033514756  |e 63000PH1033514756  |k 0/60000/  |k 1/60000/63000/  |p 3 
998 |g 1075006708  |a Kirschner, Stefanie  |m 1075006708:Kirschner, Stefanie  |d 60000  |d 63000  |e 60000PK1075006708  |e 63000PK1075006708  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1565366271  |e 2987227876 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"title":[{"title":"Journal of neuro-oncology","title_sort":"Journal of neuro-oncology"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 11.06.2018","Fortsetzung der Druck-Ausgabe"],"pubHistory":["1.1983 -"],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["32046122X"],"zdb":["2007293-4"],"issn":["1573-7373"]},"origin":[{"dateIssuedKey":"1983","publisher":"Springer Science + Business Media B.V ; Kluwer","dateIssuedDisp":"1983-","publisherPlace":"Dordrecht [u.a.] ; Dordrecht [u.a.]"}],"part":{"year":"2015","issue":"2","extent":"10","text":"122(2015), 2, Seite 245-254","pages":"245-254","volume":"122"},"recId":"32046122X","disp":"In vivo micro-CT imaging of untreated and irradiated orthotopic glioblastoma xenografts in mice capabilities, limitations and a comparison with bioluminescence imagingJournal of neuro-oncology"}],"note":["Gesehen am 15.11.2017"],"recId":"1565366271","name":{"displayForm":["Stefanie Kirschner, Manuela C. Felix, Linda Hartmann, Miriam Bierbaum, Máté E. Maros, Hans U. Kerl, Frederik Wenz, Gerhard Glatting, Martin Kramer, Frank A. Giordano, Marc A. Brockmann"]},"origin":[{"dateIssuedDisp":"22 January 2015","dateIssuedKey":"2015"}],"id":{"doi":["10.1007/s11060-014-1708-7"],"eki":["1565366271"]},"physDesc":[{"extent":"10 S."}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"In vivo micro-CT imaging of untreated and irradiated orthotopic glioblastoma xenografts in mice","subtitle":"capabilities, limitations and a comparison with bioluminescence imaging","title":"In vivo micro-CT imaging of untreated and irradiated orthotopic glioblastoma xenografts in mice"}],"person":[{"role":"aut","given":"Stefanie","family":"Kirschner","display":"Kirschner, Stefanie"},{"given":"Linda","role":"aut","family":"Hartmann","display":"Hartmann, Linda"},{"display":"Bierbaum, Miriam","family":"Bierbaum","given":"Miriam","role":"aut"},{"family":"Maros","given":"Máté E.","role":"aut","display":"Maros, Máté E."},{"role":"aut","given":"Hans Ulrich","family":"Kerl","display":"Kerl, Hans Ulrich"},{"family":"Wenz","role":"aut","given":"Frederik","display":"Wenz, Frederik"},{"display":"Glatting, Gerhard","family":"Glatting","given":"Gerhard","role":"aut"},{"given":"Frank Anton","role":"aut","family":"Giordano","display":"Giordano, Frank Anton"}]} 
SRT |a KIRSCHNERSINVIVOMICR2220