Development and validation of an automatic segmentation algorithm for quantification of intracerebral hemorrhage

Background and Purpose—ABC/2 is still widely accepted for volume estimations in spontaneous intracerebral hemorrhage (ICH) despite known limitations, which potentially accounts for controversial outcome-study results. The aim of this study was to establish and validate an automatic segmentation algo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Scherer, Moritz (VerfasserIn) , Younsi, Alexander (VerfasserIn) , Möhlenbruch, Markus Alfred (VerfasserIn) , Stock, Christian (VerfasserIn) , Bösel, Julian (VerfasserIn) , Unterberg, Andreas (VerfasserIn) , Orakcioglu, Berk (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: August 29, 2016
In: Stroke
Year: 2016, Jahrgang: 47, Heft: 11, Pages: 2776-2782
ISSN:1524-4628
DOI:10.1161/STROKEAHA.116.013779
Online-Zugang:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1161/STROKEAHA.116.013779
Verlag, kostenfrei, Volltext: http://stroke.ahajournals.org/content/47/11/2776
Volltext
Verfasserangaben:Moritz Scherer, MD; Jonas Cordes, MSc; Alexander Younsi, MD; Yasemin-Aylin Sahin, MS; Michael Götz, MSc; Markus Möhlenbruch, MD; Christian Stock, MSc, PhD; Julian Bösel, MD; Andreas Unterberg, MD, PhD; Klaus Maier-Hein, MSc, PhD; Berk Orakcioglu, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1565949781
003 DE-627
005 20220814034744.0
007 cr uuu---uuuuu
008 171201s2016 xx |||||o 00| ||eng c
024 7 |a 10.1161/STROKEAHA.116.013779  |2 doi 
035 |a (DE-627)1565949781 
035 |a (DE-576)495949787 
035 |a (DE-599)BSZ495949787 
035 |a (OCoLC)1340983003 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Scherer, Moritz  |d 1984-  |e VerfasserIn  |0 (DE-588)1026157684  |0 (DE-627)726207845  |0 (DE-576)371433983  |4 aut 
245 1 0 |a Development and validation of an automatic segmentation algorithm for quantification of intracerebral hemorrhage  |c Moritz Scherer, MD; Jonas Cordes, MSc; Alexander Younsi, MD; Yasemin-Aylin Sahin, MS; Michael Götz, MSc; Markus Möhlenbruch, MD; Christian Stock, MSc, PhD; Julian Bösel, MD; Andreas Unterberg, MD, PhD; Klaus Maier-Hein, MSc, PhD; Berk Orakcioglu, MD 
264 1 |c August 29, 2016 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 01.12.2017 
520 |a Background and Purpose—ABC/2 is still widely accepted for volume estimations in spontaneous intracerebral hemorrhage (ICH) despite known limitations, which potentially accounts for controversial outcome-study results. The aim of this study was to establish and validate an automatic segmentation algorithm, allowing for quick and accurate quantification of ICH. Methods—A segmentation algorithm implementing first- and second-order statistics, texture, and threshold features was trained on manual segmentations with a random-forest methodology. Quantitative data of the algorithm, manual segmentations, and ABC/2 were evaluated for agreement in a study sample (n=28) and validated in an independent sample not used for algorithm training (n=30). Results—ABC/2 volumes were significantly larger compared with either manual or algorithm values, whereas no significant differences were found between the latter (P<0.0001; Friedman+Dunn’s multiple comparison). Algorithm agreement with the manual reference was strong (concordance correlation coefficient 0.95 [lower 95% confidence interval 0.91]) and superior to ABC/2 (concordance correlation coefficient 0.77 [95% confidence interval 0.64]). Validation confirmed agreement in an independent sample (algorithm concordance correlation coefficient 0.99 [95% confidence interval 0.98], ABC/2 concordance correlation coefficient 0.82 [95% confidence interval 0.72]). The algorithm was closer to respective manual segmentations than ABC/2 in 52/58 cases (89.7%). Conclusions—An automatic segmentation algorithm for volumetric analysis of spontaneous ICH was developed and validated in this study. Algorithm measurements showed strong agreement with manual segmentations, whereas ABC/2 exhibited its limitations, yielding inaccurate overestimations of ICH volume. The refined, yet time-efficient, quantification of ICH by the algorithm may facilitate evaluation of clot volume as an outcome predictor and trigger for surgical interventions in the clinical setting. 
650 4 |a computed tomography 
650 4 |a computer-assisted image analysis 
650 4 |a intracerebral hemorrhage 
650 4 |a machine learning 
650 4 |a volumetric analysis 
700 1 |a Younsi, Alexander  |d 1985-  |e VerfasserIn  |0 (DE-588)104607508X  |0 (DE-627)775681547  |0 (DE-576)39935882X  |4 aut 
700 1 |a Möhlenbruch, Markus Alfred  |d 1979-  |e VerfasserIn  |0 (DE-588)137693591  |0 (DE-627)594845041  |0 (DE-576)304845655  |4 aut 
700 1 |a Stock, Christian  |d 1978-  |e VerfasserIn  |0 (DE-588)123325218  |0 (DE-627)706256530  |0 (DE-576)29365624X  |4 aut 
700 1 |a Bösel, Julian  |d 1971-  |e VerfasserIn  |0 (DE-588)122998294  |0 (DE-627)706122135  |0 (DE-576)293514038  |4 aut 
700 1 |a Unterberg, Andreas  |e VerfasserIn  |0 (DE-588)1032681187  |0 (DE-627)738641200  |0 (DE-576)168441233  |4 aut 
700 1 |a Orakcioglu, Berk  |d 1976-  |e VerfasserIn  |0 (DE-588)129877905  |0 (DE-627)482373644  |0 (DE-576)297882791  |4 aut 
773 0 8 |i Enthalten in  |t Stroke  |d New York, NY : Association, 1970  |g 47(2016), 11, Seite 2776-2782  |h Online-Ressource  |w (DE-627)266879985  |w (DE-600)1467823-8  |w (DE-576)075145731  |x 1524-4628  |7 nnas  |a Development and validation of an automatic segmentation algorithm for quantification of intracerebral hemorrhage 
773 1 8 |g volume:47  |g year:2016  |g number:11  |g pages:2776-2782  |g extent:7  |a Development and validation of an automatic segmentation algorithm for quantification of intracerebral hemorrhage 
856 4 0 |u http://dx.doi.org/10.1161/STROKEAHA.116.013779  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u http://stroke.ahajournals.org/content/47/11/2776  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20171201 
993 |a Article 
994 |a 2016 
998 |g 129877905  |a Orakcioglu, Berk  |m 129877905:Orakcioglu, Berk  |d 910000  |d 911200  |e 910000PO129877905  |e 911200PO129877905  |k 0/910000/  |k 1/910000/911200/  |p 11  |y j 
998 |g 1032681187  |a Unterberg, Andreas  |m 1032681187:Unterberg, Andreas  |d 910000  |d 911200  |e 910000PU1032681187  |e 911200PU1032681187  |k 0/910000/  |k 1/910000/911200/  |p 9 
998 |g 122998294  |a Bösel, Julian  |m 122998294:Bösel, Julian  |d 910000  |d 911100  |e 910000PB122998294  |e 911100PB122998294  |k 0/910000/  |k 1/910000/911100/  |p 8 
998 |g 123325218  |a Stock, Christian  |m 123325218:Stock, Christian  |d 910000  |d 999701  |e 910000PS123325218  |e 999701PS123325218  |k 0/910000/  |k 1/910000/999701/  |p 7 
998 |g 137693591  |a Möhlenbruch, Markus Alfred  |m 137693591:Möhlenbruch, Markus Alfred  |d 910000  |d 911100  |e 910000PM137693591  |e 911100PM137693591  |k 0/910000/  |k 1/910000/911100/  |p 6 
998 |g 104607508X  |a Younsi, Alexander  |m 104607508X:Younsi, Alexander  |d 910000  |d 911200  |e 910000PY104607508X  |e 911200PY104607508X  |k 0/910000/  |k 1/910000/911200/  |p 3 
998 |g 1026157684  |a Scherer, Moritz  |m 1026157684:Scherer, Moritz  |d 910000  |d 911200  |e 910000PS1026157684  |e 911200PS1026157684  |k 0/910000/  |k 1/910000/911200/  |p 1  |x j 
999 |a KXP-PPN1565949781  |e 298883623X 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1565949781","origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"August 29, 2016"}],"name":{"displayForm":["Moritz Scherer, MD; Jonas Cordes, MSc; Alexander Younsi, MD; Yasemin-Aylin Sahin, MS; Michael Götz, MSc; Markus Möhlenbruch, MD; Christian Stock, MSc, PhD; Julian Bösel, MD; Andreas Unterberg, MD, PhD; Klaus Maier-Hein, MSc, PhD; Berk Orakcioglu, MD"]},"person":[{"given":"Moritz","display":"Scherer, Moritz","family":"Scherer","role":"aut"},{"role":"aut","family":"Younsi","given":"Alexander","display":"Younsi, Alexander"},{"role":"aut","display":"Möhlenbruch, Markus Alfred","given":"Markus Alfred","family":"Möhlenbruch"},{"display":"Stock, Christian","given":"Christian","family":"Stock","role":"aut"},{"role":"aut","family":"Bösel","display":"Bösel, Julian","given":"Julian"},{"given":"Andreas","display":"Unterberg, Andreas","family":"Unterberg","role":"aut"},{"role":"aut","display":"Orakcioglu, Berk","given":"Berk","family":"Orakcioglu"}],"language":["eng"],"title":[{"title":"Development and validation of an automatic segmentation algorithm for quantification of intracerebral hemorrhage","title_sort":"Development and validation of an automatic segmentation algorithm for quantification of intracerebral hemorrhage"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1565949781"],"doi":["10.1161/STROKEAHA.116.013779"]},"physDesc":[{"extent":"7 S."}],"relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["1.1970 -"],"language":["eng"],"disp":"Development and validation of an automatic segmentation algorithm for quantification of intracerebral hemorrhageStroke","recId":"266879985","note":["Gesehen am 29.06.04"],"physDesc":[{"extent":"Online-Ressource"}],"part":{"year":"2016","pages":"2776-2782","text":"47(2016), 11, Seite 2776-2782","volume":"47","extent":"7","issue":"11"},"id":{"eki":["266879985"],"issn":["1524-4628"],"zdb":["1467823-8"]},"title":[{"title_sort":"Stroke","subtitle":"journal of the American Heart Association","title":"Stroke"}],"corporate":[{"display":"American Heart Association","role":"isb"}],"origin":[{"publisher":"Association ; Lippincott Williams & Wilkins","dateIssuedDisp":"1970-","dateIssuedKey":"1970","publisherPlace":"New York, NY ; Philadelphia, Pa."}]}],"note":["Gesehen am 01.12.2017"]} 
SRT |a SCHERERMORDEVELOPMEN2920