Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns

Background:Shear stress at the stump in trans-tibial amputees induced by turning movements may be reduced with the use of torsion adapters in the prosthesis.Objective:Monitoring the motion and kinetic effects of a regular torsion adapter in comparison to a rigid placebo in unplanned spin and step tu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Heitzmann, Daniel (VerfasserIn) , Alimusaj, Merkur (VerfasserIn) , Block, Julia (VerfasserIn) , Putz, Cornelia (VerfasserIn) , Wolf, Sebastian Immanuel (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2016
In: Prosthetics and orthotics international
Year: 2016, Jahrgang: 40, Heft: 5, Pages: 558-565
ISSN:1746-1553
DOI:10.1177/0309364615592698
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1177/0309364615592698
Verlag, Volltext: https://doi.org/10.1177/0309364615592698
Volltext
Verfasserangaben:Daniel WW Heitzmann, Kai Pieschel, Merkur Alimusaj, Julia Block, Cornelia Putz and Sebastian I Wolf

MARC

LEADER 00000caa a2200000 c 4500
001 1566060869
003 DE-627
005 20220814035647.0
007 cr uuu---uuuuu
008 171205s2016 xx |||||o 00| ||eng c
024 7 |a 10.1177/0309364615592698  |2 doi 
035 |a (DE-627)1566060869 
035 |a (DE-576)496060864 
035 |a (DE-599)BSZ496060864 
035 |a (OCoLC)1340982939 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Heitzmann, Daniel  |e VerfasserIn  |0 (DE-588)1084604930  |0 (DE-627)848576918  |0 (DE-576)456356983  |4 aut 
245 1 0 |a Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns  |c Daniel WW Heitzmann, Kai Pieschel, Merkur Alimusaj, Julia Block, Cornelia Putz and Sebastian I Wolf 
264 1 |c 2016 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First Published July 20, 2015 
500 |a Gesehen am 05.12.2017 
520 |a Background:Shear stress at the stump in trans-tibial amputees induced by turning movements may be reduced with the use of torsion adapters in the prosthesis.Objective:Monitoring the motion and kinetic effects of a regular torsion adapter in comparison to a rigid placebo in unplanned spin and step turns.Study design:Single-blinded placebo-controlled cohort study.Methods:In total, 10 trans-tibial amputees underwent three-dimensional gait analysis in level walking and unplanned spin and step turns with a torsion adapter and with a rigid placebo.Results:Kinetic effects varied among participants. No statistically significant reduction of peak internal and peak external transverse plane moments was found for the torsion adapter in any walking condition. However, transverse plane rotation of the adapter was monitored in all participants.Conclusion:Motion between the socket and the residual limb may be reduced during turns due to transverse plane motion of the torsion adapter and shear stress on the residual limb may be reduced. However, there may be good and bad responders to torsion adapters due to differences in coupling between the residual limb and the socket.Clinical relevanceStrong coupling between stump and socket will help the user controlling his prosthesis. Shear stress at the stump may increase in stump?socket interface stiffness and may be the reason for residual limb problems. Torsion adapters therefore may be beneficial for comfort and stump condition in individual cases. 
700 1 |a Alimusaj, Merkur  |e VerfasserIn  |0 (DE-588)1046144685  |0 (DE-627)775784710  |0 (DE-576)39941245X  |4 aut 
700 1 |a Block, Julia  |e VerfasserIn  |0 (DE-588)114780785X  |0 (DE-627)100720818X  |0 (DE-576)496060252  |4 aut 
700 1 |a Putz, Cornelia  |d 1979-  |e VerfasserIn  |0 (DE-588)132069296  |0 (DE-627)517465272  |0 (DE-576)29892692X  |4 aut 
700 1 |a Wolf, Sebastian Immanuel  |d 1965-  |e VerfasserIn  |0 (DE-588)1051004578  |0 (DE-627)785483861  |0 (DE-576)40544849X  |4 aut 
773 0 8 |i Enthalten in  |t Prosthetics and orthotics international  |d [Erscheinungsort nicht ermittelbar] : Wolters Kluwer, 1977  |g 40(2016), 5, Seite 558-565  |h Online-Ressource  |w (DE-627)501078509  |w (DE-600)2205993-3  |w (DE-576)277733294  |x 1746-1553  |7 nnas  |a Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns 
773 1 8 |g volume:40  |g year:2016  |g number:5  |g pages:558-565  |g extent:8  |a Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns 
856 4 0 |u http://dx.doi.org/10.1177/0309364615592698  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1177/0309364615592698  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20171205 
993 |a Article 
994 |a 2016 
998 |g 1051004578  |a Wolf, Sebastian Immanuel  |m 1051004578:Wolf, Sebastian Immanuel  |d 910000  |d 911460  |e 910000PW1051004578  |e 911460PW1051004578  |k 0/910000/  |k 1/910000/911460/  |p 6  |y j 
998 |g 132069296  |a Putz, Cornelia  |m 132069296:Putz, Cornelia  |d 910000  |d 911460  |e 910000PP132069296  |e 911460PP132069296  |k 0/910000/  |k 1/910000/911460/  |p 5 
998 |g 114780785X  |a Block, Julia  |m 114780785X:Block, Julia  |d 910000  |d 911460  |e 910000PB114780785X  |e 911460PB114780785X  |k 0/910000/  |k 1/910000/911460/  |p 4 
998 |g 1046144685  |a Alimusaj, Merkur  |m 1046144685:Alimusaj, Merkur  |d 910000  |d 911460  |e 910000PA1046144685  |e 911460PA1046144685  |k 0/910000/  |k 1/910000/911460/  |p 3 
998 |g 1084604930  |a Heitzmann, Daniel  |m 1084604930:Heitzmann, Daniel  |d 910000  |d 911460  |e 910000PH1084604930  |e 911460PH1084604930  |k 0/910000/  |k 1/910000/911460/  |p 1  |x j 
999 |a KXP-PPN1566060869  |e 2989232354 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"8 S."}],"id":{"eki":["1566060869"],"doi":["10.1177/0309364615592698"]},"title":[{"title_sort":"Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns","title":"Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"2016","dateIssuedKey":"2016"}],"relHost":[{"title":[{"title":"Prosthetics and orthotics international","subtitle":"the journal of the International Society for Prosthetics and Orthotics","title_sort":"Prosthetics and orthotics international"}],"id":{"issn":["1746-1553"],"eki":["501078509"],"zdb":["2205993-3"]},"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"publisher":"Wolters Kluwer ; Taylor & Francis ; Informa Healthcare ; Sage Publishing","dateIssuedDisp":"1977-","dateIssuedKey":"1977","publisherPlace":"[Erscheinungsort nicht ermittelbar] ; London [u.a.] ; London [u.a.] ; London"}],"recId":"501078509","disp":"Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turnsProsthetics and orthotics international","type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"Prosthetics and orthotics international"}],"language":["eng"],"part":{"year":"2016","volume":"40","text":"40(2016), 5, Seite 558-565","issue":"5","pages":"558-565","extent":"8"},"note":["Gesehen am 10.02.2021","Fortsetzung der Druck-Ausgabe"],"pubHistory":["1.1977 -"]}],"language":["eng"],"name":{"displayForm":["Daniel WW Heitzmann, Kai Pieschel, Merkur Alimusaj, Julia Block, Cornelia Putz and Sebastian I Wolf"]},"note":["First Published July 20, 2015","Gesehen am 05.12.2017"],"recId":"1566060869","person":[{"display":"Heitzmann, Daniel","given":"Daniel","role":"aut","family":"Heitzmann"},{"given":"Merkur","display":"Alimusaj, Merkur","role":"aut","family":"Alimusaj"},{"given":"Julia","display":"Block, Julia","role":"aut","family":"Block"},{"given":"Cornelia","display":"Putz, Cornelia","family":"Putz","role":"aut"},{"role":"aut","family":"Wolf","given":"Sebastian Immanuel","display":"Wolf, Sebastian Immanuel"}]} 
SRT |a HEITZMANNDFUNCTIONAL2016