Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery
Insertion of a Totally Implantable Access Port (TIAP) can be performed either via Central Vein Puncture (CVP) or Brachiocephalic Vein Cut-down (venous section-VS). The primary success rate of TIAP implantation using VS rarely ever achieves 100%. The objective of this study was to describe a modified...
Gespeichert in:
| Hauptverfasser: | , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
7 December 2017
|
| In: |
BMC surgery
Year: 2017, Jahrgang: 17, Pages: 1-7 |
| ISSN: | 1471-2482 |
| DOI: | 10.1186/s12893-017-0329-4 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1186/s12893-017-0329-4 Verlag, kostenfrei, Volltext: https://doi.org/10.1186/s12893-017-0329-4 |
| Verfasserangaben: | Georgios Polychronidis, Roland Hennes, Cosima Engerer, Phillip Knebel, Daniel Schultze, Thomas Bruckner, Beat P. Müller-Stich and Lars Fischer |
MARC
| LEADER | 00000caa a2200000 4500 | ||
|---|---|---|---|
| 001 | 1567308295 | ||
| 003 | DE-627 | ||
| 005 | 20230531085435.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180118s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1186/s12893-017-0329-4 |2 doi | |
| 035 | |a (DE-627)1567308295 | ||
| 035 | |a (DE-576)497308290 | ||
| 035 | |a (DE-599)BSZ497308290 | ||
| 035 | |a (OCoLC)1263961628 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Polychronidis, Georgios |d 1984- |e VerfasserIn |0 (DE-588)1071576984 |0 (DE-627)826052975 |0 (DE-576)433162384 |4 aut | |
| 245 | 1 | 0 | |a Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery |c Georgios Polychronidis, Roland Hennes, Cosima Engerer, Phillip Knebel, Daniel Schultze, Thomas Bruckner, Beat P. Müller-Stich and Lars Fischer |
| 264 | 1 | |c 7 December 2017 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 18.01.2018 | ||
| 520 | |a Insertion of a Totally Implantable Access Port (TIAP) can be performed either via Central Vein Puncture (CVP) or Brachiocephalic Vein Cut-down (venous section-VS). The primary success rate of TIAP implantation using VS rarely ever achieves 100%. The objective of this study was to describe a modified VS approach using a hydrophilic coated wire (TVS). | ||
| 650 | 4 | |a Guide wire | |
| 650 | 4 | |a Pneumothorax | |
| 650 | 4 | |a Totally implantable access port | |
| 650 | 4 | |a Venous cut-down | |
| 700 | 1 | |a Hennes, Roland |d 19XX- |e VerfasserIn |0 (DE-588)1066868530 |0 (DE-627)817988661 |0 (DE-576)426254139 |4 aut | |
| 700 | 1 | |a Engerer, Cosima |e VerfasserIn |0 (DE-588)115087743X |0 (DE-627)1011137488 |0 (DE-576)496900757 |4 aut | |
| 700 | 1 | |a Knebel, Phillip |d 1977- |e VerfasserIn |0 (DE-588)131961829 |0 (DE-627)516320114 |0 (DE-576)298863170 |4 aut | |
| 700 | 1 | |a Schultze, Daniel |d 1980- |e VerfasserIn |0 (DE-588)1054785260 |0 (DE-627)792111532 |0 (DE-576)410512958 |4 aut | |
| 700 | 1 | |a Bruckner, Thomas |d 1956- |e VerfasserIn |0 (DE-588)136046215 |0 (DE-627)574429298 |0 (DE-576)300798768 |4 aut | |
| 700 | 1 | |a Müller, Beat P. |d 1971- |e VerfasserIn |0 (DE-588)14066209X |0 (DE-627)70374819X |0 (DE-576)317992287 |4 aut | |
| 700 | 1 | |a Fischer, Lars |d 1971- |e VerfasserIn |0 (DE-588)122982606 |0 (DE-627)706116674 |0 (DE-576)302554661 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t BMC surgery |d London : BioMed Central, 2001 |g 17(2017), Artikel-ID 131, Seite 1-7 |h Online-Ressource |w (DE-627)331018837 |w (DE-600)2050442-1 |w (DE-576)107014971 |x 1471-2482 |7 nnns |a Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery |
| 773 | 1 | 8 | |g volume:17 |g year:2017 |g elocationid:131 |g pages:1-7 |g extent:7 |a Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1186/s12893-017-0329-4 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |
| 856 | 4 | 0 | |u https://doi.org/10.1186/s12893-017-0329-4 |x Verlag |z kostenfrei |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180118 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 122982606 |a Fischer, Lars |m 122982606:Fischer, Lars |d 910000 |d 910200 |d 50000 |e 910000PF122982606 |e 910200PF122982606 |e 50000PF122982606 |k 0/910000/ |k 1/910000/910200/ |k 0/50000/ |p 8 |y j | ||
| 998 | |g 14066209X |a Müller, Beat P. |m 14066209X:Müller, Beat P. |d 910000 |d 910200 |e 910000PM14066209X |e 910200PM14066209X |k 0/910000/ |k 1/910000/910200/ |p 7 | ||
| 998 | |g 136046215 |a Bruckner, Thomas |m 136046215:Bruckner, Thomas |d 910000 |d 999701 |e 910000PB136046215 |e 999701PB136046215 |k 0/910000/ |k 1/910000/999701/ |p 6 | ||
| 998 | |g 1054785260 |a Schultze, Daniel |m 1054785260:Schultze, Daniel |d 910000 |d 910200 |e 910000PS1054785260 |e 910200PS1054785260 |k 0/910000/ |k 1/910000/910200/ |p 5 | ||
| 998 | |g 131961829 |a Knebel, Phillip |m 131961829:Knebel, Phillip |d 910000 |d 910200 |e 910000PK131961829 |e 910200PK131961829 |k 0/910000/ |k 1/910000/910200/ |p 4 | ||
| 998 | |g 115087743X |a Engerer, Cosima |m 115087743X:Engerer, Cosima |d 910000 |d 910200 |e 910000PE115087743X |e 910200PE115087743X |k 0/910000/ |k 1/910000/910200/ |p 3 | ||
| 998 | |g 1066868530 |a Hennes, Roland |m 1066868530:Hennes, Roland |d 910000 |d 910200 |e 910000PH1066868530 |e 910200PH1066868530 |k 0/910000/ |k 1/910000/910200/ |p 2 | ||
| 998 | |g 1071576984 |a Polychronidis, Georgios |m 1071576984:Polychronidis, Georgios |d 910000 |d 910200 |e 910000PP1071576984 |e 910200PP1071576984 |k 0/910000/ |k 1/910000/910200/ |p 1 |x j | ||
| 999 | |a KXP-PPN1567308295 |e 2993077627 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"origin":[{"dateIssuedDisp":"7 December 2017","dateIssuedKey":"2017"}],"title":[{"title":"Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery","title_sort":"Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgery"}],"note":["Gesehen am 18.01.2018"],"physDesc":[{"extent":"S.7"}],"name":{"displayForm":["Georgios Polychronidis, Roland Hennes, Cosima Engerer, Phillip Knebel, Daniel Schultze, Thomas Bruckner, Beat P. Müller-Stich and Lars Fischer"]},"person":[{"roleDisplay":"VerfasserIn","given":"Georgios","family":"Polychronidis","display":"Polychronidis, Georgios","role":"aut"},{"display":"Hennes, Roland","role":"aut","family":"Hennes","given":"Roland","roleDisplay":"VerfasserIn"},{"role":"aut","display":"Engerer, Cosima","family":"Engerer","given":"Cosima","roleDisplay":"VerfasserIn"},{"display":"Knebel, Phillip","role":"aut","family":"Knebel","given":"Phillip","roleDisplay":"VerfasserIn"},{"family":"Schultze","role":"aut","display":"Schultze, Daniel","roleDisplay":"VerfasserIn","given":"Daniel"},{"roleDisplay":"VerfasserIn","given":"Thomas","family":"Bruckner","role":"aut","display":"Bruckner, Thomas"},{"display":"Müller, Beat P.","role":"aut","family":"Müller","given":"Beat P.","roleDisplay":"VerfasserIn"},{"display":"Fischer, Lars","role":"aut","family":"Fischer","given":"Lars","roleDisplay":"VerfasserIn"}],"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"physDesc":[{"extent":"Online-Ressource"}],"disp":"Use of a hydrophilic coating wire reduces significantly the rate of central vein punctures and the incidence of pneumothorax in totally implantable access port (TIAP) surgeryBMC surgery","language":["eng"],"origin":[{"dateIssuedKey":"2001","publisherPlace":"London","publisher":"BioMed Central","dateIssuedDisp":"2001-"}],"part":{"volume":"17","pages":"1-7","extent":"7","text":"17(2017), Artikel-ID 131, Seite 1-7","year":"2017"},"pubHistory":["1.2001 -"],"recId":"331018837","id":{"issn":["1471-2482"],"zdb":["2050442-1"],"eki":["331018837"]},"note":["Gesehen am 20. Januar 2016"],"title":[{"title":"BMC surgery","title_sort":"BMC surgery"}]}],"id":{"doi":["10.1186/s12893-017-0329-4"],"eki":["1567308295"]},"recId":"1567308295"} | ||
| SRT | |a POLYCHRONIUSEOFAHYDR7201 | ||