Determination of dabigatran in plasma, serum, and urine samples: comparison of six methods

Background: Assessing the anticoagulant effect of dabigatran may be useful in certain clinical settings. When plasma sampling is not available, serum or urine samples may provide another option for dabigatran determinations. Methods: Dabigatran was assessed in patients on treatment under real-life c...

Full description

Saved in:
Bibliographic Details
Main Authors: Du, Shanshan (Author) , Weiß, Christel (Author) , Wehling, Martin (Author) , Krämer, Roland (Author)
Format: Article (Journal)
Language:English
Published: January 23, 2015
In: Clinical chemistry and laboratory medicine
Year: 2015, Volume: 53, Issue: 8, Pages: 1237-1247
ISSN:1437-4331
DOI:10.1515/cclm-2014-0991
Online Access:Verlag, Volltext: http://dx.doi.org/10.1515/cclm-2014-0991
Verlag, Volltext: https://www.degruyterbrill.com/view/j/cclm.2015.53.issue-8/cclm-2014-0991/cclm-2014-0991.xml
Get full text
Author Notes:Shanshan Du, Christel Weiss, Giese Christina, Sandra Krämer, Martin Wehling, Roland Krämer and Job Harenberg

MARC

LEADER 00000caa a2200000 c 4500
001 1567360254
003 DE-627
005 20250530010143.0
007 cr uuu---uuuuu
008 180119s2015 xx |||||o 00| ||eng c
024 7 |a 10.1515/cclm-2014-0991  |2 doi 
035 |a (DE-627)1567360254 
035 |a (DE-576)49736025X 
035 |a (DE-599)BSZ49736025X 
035 |a (OCoLC)1340986071 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Du, Shanshan  |d 1985-  |e VerfasserIn  |0 (DE-588)1033633518  |0 (DE-627)742102807  |0 (DE-576)381257843  |4 aut 
245 1 0 |a Determination of dabigatran in plasma, serum, and urine samples  |b comparison of six methods  |c Shanshan Du, Christel Weiss, Giese Christina, Sandra Krämer, Martin Wehling, Roland Krämer and Job Harenberg 
264 1 |c January 23, 2015 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 19.01.2018 
520 |a Background: Assessing the anticoagulant effect of dabigatran may be useful in certain clinical settings. When plasma sampling is not available, serum or urine samples may provide another option for dabigatran determinations. Methods: Dabigatran was assessed in patients on treatment under real-life conditions in plasma samples by four clotting time-based assays and in plasma, serum, and urine samples by two chromogenic substrate methods. Results: The concentrations of dabigatran in patients’ plasma samples were not different for the Hemoclot test (106.8±89.4 ng/mL) and the ecarin clotting time (ECT, 109.5±74.5 ng/mL, p=0.58). Activated partial thromboplastin time and prothrombinase-induced clotting time showed low correlations with the other assays. Chromogenic assays measured similar concentrations as Hemoclot and ECT. For both chromogenic assays, the concentrations of dabigatran were about 70% lower in serum than in plasma samples (p<0.0001). The intra-class coefficient (ICC, Bland-Altman analysis) was strong comparing ECT, Hemoclot thrombin inhibitor (HTI) assay, and the two chromogenic assays (r=0.889–0.737). The ICC was low for comparisons of the chromogenic assays of serum vs. plasma values (ICC, 0.15 and 0.66). The ICC for the determination of dabigatran in urine samples by the two chromogenic assays (5641.6±4319.7 and 4730.0±3770.2 ng/mL) was 0.737. Conclusions: ECT, HTI, and chromogenic assays can be used to determine dabigatran in plasma samples from patients under real-life conditions. Chromogenic assays require further improvement to reliably measure dabigatran in serum samples. Dabigatran concentrations in urine samples can also be determined quantitatively. 
650 4 |a chromogenic substrate methods 
650 4 |a clotting time assays 
650 4 |a dabigatran 
650 4 |a plasma 
650 4 |a serum 
650 4 |a urine 
700 1 |a Weiß, Christel  |d 1958-  |e VerfasserIn  |0 (DE-588)123287707  |0 (DE-627)082463417  |0 (DE-576)168356104  |4 aut 
700 1 |a Wehling, Martin  |d 1957-  |e VerfasserIn  |0 (DE-588)129939331  |0 (DE-627)484463152  |0 (DE-576)297912577  |4 aut 
700 1 |a Krämer, Roland  |e VerfasserIn  |0 (DE-588)1020469730  |0 (DE-627)691227861  |0 (DE-576)360500331  |4 aut 
773 0 8 |i Enthalten in  |t Clinical chemistry and laboratory medicine  |d Berlin [u.a.] : De Gruyter, 1998  |g 53(2015), 8, Seite 1237-1247  |h Online-Ressource  |w (DE-627)302923187  |w (DE-600)1492732-9  |w (DE-576)088704882  |x 1437-4331  |7 nnas  |a Determination of dabigatran in plasma, serum, and urine samples comparison of six methods 
773 1 8 |g volume:53  |g year:2015  |g number:8  |g pages:1237-1247  |g extent:11  |a Determination of dabigatran in plasma, serum, and urine samples comparison of six methods 
856 4 0 |u http://dx.doi.org/10.1515/cclm-2014-0991  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://www.degruyterbrill.com/view/j/cclm.2015.53.issue-8/cclm-2014-0991/cclm-2014-0991.xml  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180119 
993 |a Article 
994 |a 2015 
998 |g 1020469730  |a Krämer, Roland  |m 1020469730:Krämer, Roland  |d 120000  |d 120200  |e 120000PK1020469730  |e 120200PK1020469730  |k 0/120000/  |k 1/120000/120200/  |p 6 
998 |g 129939331  |a Wehling, Martin  |m 129939331:Wehling, Martin  |d 60000  |d 65400  |e 60000PW129939331  |e 65400PW129939331  |k 0/60000/  |k 1/60000/65400/  |p 5 
998 |g 123287707  |a Weiß, Christel  |m 123287707:Weiß, Christel  |d 60000  |d 60200  |d 60250  |e 60000PW123287707  |e 60200PW123287707  |e 60250PW123287707  |k 0/60000/  |k 1/60000/60200/  |k 2/60000/60200/60250/  |p 2 
999 |a KXP-PPN1567360254  |e 2993174932 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Shanshan Du, Christel Weiss, Giese Christina, Sandra Krämer, Martin Wehling, Roland Krämer and Job Harenberg"]},"physDesc":[{"extent":"11 S."}],"person":[{"family":"Du","role":"aut","display":"Du, Shanshan","given":"Shanshan"},{"display":"Weiß, Christel","given":"Christel","role":"aut","family":"Weiß"},{"given":"Martin","display":"Wehling, Martin","role":"aut","family":"Wehling"},{"given":"Roland","display":"Krämer, Roland","family":"Krämer","role":"aut"}],"relHost":[{"name":{"displayForm":["publ. in association with the International Federation of Clinical Chemistry and Laboratory Medicine and the Forum of the European Societies of Clinical Chemistry"]},"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["36.1998-"],"titleAlt":[{"title":"CCLM"}],"language":["eng"],"part":{"volume":"53","pages":"1237-1247","text":"53(2015), 8, Seite 1237-1247","issue":"8","extent":"11","year":"2015"},"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"dateIssuedDisp":"1998-","dateIssuedKey":"1998","publisherPlace":"Berlin [u.a.]","publisher":"De Gruyter"}],"disp":"Determination of dabigatran in plasma, serum, and urine samples comparison of six methodsClinical chemistry and laboratory medicine","recId":"302923187","id":{"issn":["1437-4331"],"doi":["10.1515/cclm"],"zdb":["1492732-9"],"eki":["302923187"]},"title":[{"title":"Clinical chemistry and laboratory medicine","title_sort":"Clinical chemistry and laboratory medicine"}],"note":["Gesehen am 22.6.2022"]}],"origin":[{"dateIssuedDisp":"January 23, 2015","dateIssuedKey":"2015"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 19.01.2018"],"title":[{"subtitle":"comparison of six methods","title_sort":"Determination of dabigatran in plasma, serum, and urine samples","title":"Determination of dabigatran in plasma, serum, and urine samples"}],"id":{"eki":["1567360254"],"doi":["10.1515/cclm-2014-0991"]},"recId":"1567360254"} 
SRT |a DUSHANSHANDETERMINAT2320