In vivo quantification of gentamicin released from an implant coating

Drug-releasing implants are gaining increasing interest. The present study reports a detailed physicochemical analysis of a polymeric coating based on poly(D,L-lactide) and the incorporated gentamicin combined with an in vitro and in vivo study of the gentamicin release. Differential scanning calori...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Nast, Sophie (VerfasserIn) , Schmidmaier, Gerhard (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: February 10, 2016
In: Journal of biomaterials applications
Year: 2016, Jahrgang: 31, Heft: 1, Pages: 45-54
ISSN:1530-8022
DOI:10.1177/0885328216630912
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1177/0885328216630912
Verlag, Volltext: https://doi.org/10.1177/0885328216630912
Volltext
Verfasserangaben:S. Nast, M. Fassbender, N. Bormann, S. Beck, A. Montali, M. Lucke, G. Schmidmaier and B. Wildemann

MARC

LEADER 00000caa a2200000 c 4500
001 1569756694
003 DE-627
005 20250206095051.0
007 cr uuu---uuuuu
008 180212s2016 xx |||||o 00| ||eng c
024 7 |a 10.1177/0885328216630912  |2 doi 
035 |a (DE-627)1569756694 
035 |a (DE-576)49975669X 
035 |a (DE-599)BSZ49975669X 
035 |a (OCoLC)1340987261 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Nast, Sophie  |e VerfasserIn  |0 (DE-588)1152237357  |0 (DE-627)101372061X  |0 (DE-576)499756533  |4 aut 
245 1 0 |a In vivo quantification of gentamicin released from an implant coating  |c S. Nast, M. Fassbender, N. Bormann, S. Beck, A. Montali, M. Lucke, G. Schmidmaier and B. Wildemann 
264 1 |c February 10, 2016 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 12.02.2018 
520 |a Drug-releasing implants are gaining increasing interest. The present study reports a detailed physicochemical analysis of a polymeric coating based on poly(D,L-lactide) and the incorporated gentamicin combined with an in vitro and in vivo study of the gentamicin release. Differential scanning calorimeter, Fourier transform infrared spectroscopy, gel permeation chromatography and high-performance liquid chromatography showed no effect of the gamma sterilisation on the coating components or an interaction of the polymer and the gentamicin. Microbiological analysis revealed an inhibition of bacterial growth on the implant surface. For the in vivo study, gentamicin-coated wires were implanted into the tibiae of rats and harvested at different time points up to day 42. To monitor the release in vivo, gentamicin was quantified in serum, bone, endosteum, kidney, and on the explanted wires. Gentamicin was detectable over a time period of 42 days in the endosteum, up to seven days in the kidney, up to 4 h in the bone and at the end of the experiment on one of eight wires. The locally released gentamicin caused no histological changes of the kidney. Microbiologically active concentrations of released gentamicin were found in the endosteum up to 4 h after implantation. The combination of different methods supports the individual results, where quantification is complemented by visualisation or antimicrobial activity. This work demonstrates that the coating procedure results in no substantial alteration of the incorporated drug and that the in vitro burst release occurs also in vivo. 
700 1 |a Schmidmaier, Gerhard  |d 1970-  |e VerfasserIn  |0 (DE-588)121147207  |0 (DE-627)394702662  |0 (DE-576)292558600  |4 aut 
773 0 8 |i Enthalten in  |t Journal of biomaterials applications  |d Thousand Oaks, Calif. [u.a.] : Sage, 1986  |g 31(2016), 1, Seite 45-54  |h Online-Ressource  |w (DE-627)342893572  |w (DE-600)2072559-0  |w (DE-576)111552265  |x 1530-8022  |7 nnas  |a In vivo quantification of gentamicin released from an implant coating 
773 1 8 |g volume:31  |g year:2016  |g number:1  |g pages:45-54  |g extent:10  |a In vivo quantification of gentamicin released from an implant coating 
856 4 0 |u http://dx.doi.org/10.1177/0885328216630912  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://doi.org/10.1177/0885328216630912  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180212 
993 |a Article 
994 |a 2016 
998 |g 121147207  |a Schmidmaier, Gerhard  |m 121147207:Schmidmaier, Gerhard  |d 910000  |d 911460  |e 910000PS121147207  |e 911460PS121147207  |k 0/910000/  |k 1/910000/911460/  |p 7 
999 |a KXP-PPN1569756694  |e 299878223X 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"In vivo quantification of gentamicin released from an implant coating","title_sort":"In vivo quantification of gentamicin released from an implant coating"}],"person":[{"given":"Sophie","display":"Nast, Sophie","role":"aut","family":"Nast"},{"display":"Schmidmaier, Gerhard","given":"Gerhard","role":"aut","family":"Schmidmaier"}],"physDesc":[{"extent":"10 S."}],"id":{"eki":["1569756694"],"doi":["10.1177/0885328216630912"]},"language":["eng"],"name":{"displayForm":["S. Nast, M. Fassbender, N. Bormann, S. Beck, A. Montali, M. Lucke, G. Schmidmaier and B. Wildemann"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1569756694","relHost":[{"language":["eng"],"id":{"eki":["342893572"],"zdb":["2072559-0"],"issn":["1530-8022"]},"note":["Gesehen am 19.05.08"],"origin":[{"publisherPlace":"Thousand Oaks, Calif. [u.a.]","dateIssuedKey":"1986","dateIssuedDisp":"1986-","publisher":"Sage"}],"pubHistory":["1.1986 -"],"recId":"342893572","type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title":"Journal of biomaterials applications","title_sort":"Journal of biomaterials applications"}],"part":{"extent":"10","volume":"31","issue":"1","pages":"45-54","year":"2016","text":"31(2016), 1, Seite 45-54"},"disp":"In vivo quantification of gentamicin released from an implant coatingJournal of biomaterials applications","physDesc":[{"extent":"Online-Ressource"}],"titleAlt":[{"title":"Biomaterials applications"}]}],"origin":[{"dateIssuedDisp":"February 10, 2016","dateIssuedKey":"2016"}],"note":["Gesehen am 12.02.2018"]} 
SRT |a NASTSOPHIEINVIVOQUAN1020