Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclides

The triple-trap mass spectrometer ISOLTRAP at ISOLDE/CERN has demonstrated the feasibility of mass spectrometry of in-trap-decay product ions. This novel technique gives access to radionuclides, which are not produced directly at ISOL-type radioactive ion beam facilities. As a proof of principle, th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Herlert, Alexander (VerfasserIn) , Herfurth, Frank (VerfasserIn) , Kluge, Heinz-Jürgen (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 8 February 2005
In: New journal of physics
Year: 2005, Jahrgang: 7, Heft: 1
ISSN:1367-2630
DOI:10.1088/1367-2630/7/1/044
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1088/1367-2630/7/1/044
Verlag, Volltext: http://stacks.iop.org/1367-2630/7/i=1/a=044
Volltext
Verfasserangaben:A Herlert, D Beck, K Blaum, F Carrel, P Delahaye, S George, C Guénaut, F Herfurth, A Kellerbauer, H-J Kluge, D Lunney, M Mukherjee, L Schweikhard and C Yazidjian

MARC

LEADER 00000caa a2200000 c 4500
001 1570132712
003 DE-627
005 20220814081735.0
007 cr uuu---uuuuu
008 180223s2005 xx |||||o 00| ||eng c
024 7 |a 10.1088/1367-2630/7/1/044  |2 doi 
035 |a (DE-627)1570132712 
035 |a (DE-576)500132712 
035 |a (DE-599)BSZ500132712 
035 |a (OCoLC)1340992151 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Herlert, Alexander  |d 1972-  |e VerfasserIn  |0 (DE-588)128350717  |0 (DE-627)372607918  |0 (DE-576)297093371  |4 aut 
245 1 0 |a Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclides  |c A Herlert, D Beck, K Blaum, F Carrel, P Delahaye, S George, C Guénaut, F Herfurth, A Kellerbauer, H-J Kluge, D Lunney, M Mukherjee, L Schweikhard and C Yazidjian 
264 1 |c 8 February 2005 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 27.02.2020 
520 |a The triple-trap mass spectrometer ISOLTRAP at ISOLDE/CERN has demonstrated the feasibility of mass spectrometry of in-trap-decay product ions. This novel technique gives access to radionuclides, which are not produced directly at ISOL-type radioactive ion beam facilities. As a proof of principle, the in-trap decay of 37 K + has been investigated in a Penning trap filled with helium buffer gas. The half-life of the mother nuclide was confirmed and the recoiling 37 Ar + daughter ion was contained within the trap. The ions of either the mother or the daughter nuclide were transferred to a precision Penning trap, where their mass was determined. 
700 1 |a Herfurth, Frank  |e VerfasserIn  |0 (DE-588)131771736  |0 (DE-627)513945539  |0 (DE-576)172796482  |4 aut 
700 1 |a Kluge, Heinz-Jürgen  |d 1941-  |e VerfasserIn  |0 (DE-588)115414487  |0 (DE-627)28400474X  |0 (DE-576)289870267  |4 aut 
773 0 8 |i Enthalten in  |t New journal of physics  |d [Bad Honnef] : Dt. Physikalische Ges., 1999  |g 7(2005,1) Artikel-Nummer 44, 11 Seiten  |h Online-Ressource  |w (DE-627)265510562  |w (DE-600)1464444-7  |w (DE-576)078991846  |x 1367-2630  |7 nnas  |a Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclides 
773 1 8 |g volume:7  |g year:2005  |g number:1  |g extent:11  |a Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclides 
856 4 0 |u http://dx.doi.org/10.1088/1367-2630/7/1/044  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://stacks.iop.org/1367-2630/7/i=1/a=044  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180223 
993 |a Article 
994 |a 2005 
998 |g 115414487  |a Kluge, Heinz-Jürgen  |m 115414487:Kluge, Heinz-Jürgen  |d 130000  |d 130200  |e 130000PK115414487  |e 130200PK115414487  |k 0/130000/  |k 1/130000/130200/  |p 10 
998 |g 131771736  |a Herfurth, Frank  |m 131771736:Herfurth, Frank  |p 8 
999 |a KXP-PPN1570132712  |e 3000411097 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"roleDisplay":"VerfasserIn","display":"Herlert, Alexander","role":"aut","family":"Herlert","given":"Alexander"},{"roleDisplay":"VerfasserIn","display":"Herfurth, Frank","role":"aut","family":"Herfurth","given":"Frank"},{"family":"Kluge","given":"Heinz-Jürgen","roleDisplay":"VerfasserIn","display":"Kluge, Heinz-Jürgen","role":"aut"}],"title":[{"title":"Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclides","title_sort":"Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclides"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 27.02.2020"],"recId":"1570132712","language":["eng"],"name":{"displayForm":["A Herlert, D Beck, K Blaum, F Carrel, P Delahaye, S George, C Guénaut, F Herfurth, A Kellerbauer, H-J Kluge, D Lunney, M Mukherjee, L Schweikhard and C Yazidjian"]},"origin":[{"dateIssuedKey":"2005","dateIssuedDisp":"8 February 2005"}],"id":{"eki":["1570132712"],"doi":["10.1088/1367-2630/7/1/044"]},"physDesc":[{"extent":"11 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"name":{"displayForm":["Deutsche Physikalische Gesellschaft ; IOP, Institute of Physics"]},"origin":[{"publisherPlace":"[Bad Honnef] ; [London]","dateIssuedDisp":"1999-","dateIssuedKey":"1999","publisher":"Dt. Physikalische Ges. ; IOP"}],"id":{"zdb":["1464444-7"],"eki":["265510562"],"issn":["1367-2630"]},"note":["Gesehen am 16.06.20"],"disp":"Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclidesNew journal of physics","type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"corporate":[{"roleDisplay":"Herausgebendes Organ","display":"Institute of Physics","role":"isb"},{"roleDisplay":"Herausgebendes Organ","display":"Deutsche Physikalische Gesellschaft","role":"isb"}],"recId":"265510562","pubHistory":["1.1998/99(1999) -"],"part":{"year":"2005","issue":"1","text":"7(2005,1) Artikel-Nummer 44, 11 Seiten","volume":"7","extent":"11"},"title":[{"title_sort":"New journal of physics","title":"New journal of physics","subtitle":"the open-access journal for physics"}]}]} 
SRT |a HERLERTALEMASSSPECTR8200