Is an extension of the safe zone possible without jeopardizing the proximal radioulnar joint when performing a radial head plate osteosynthesis?
Background: Proximal radial fractures are common elbow injuries. Because of the fracture pattern, stability criteria, or plate configuration, a plate position outside the “safe zone” (SZ) may be required in some cases when performing a radial head plate osteosynthesis. We examined the gross anatomy...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
October 2015
|
| In: |
Journal of shoulder and elbow surgery
Year: 2015, Volume: 24, Issue: 10, Pages: 1627-1634 |
| ISSN: | 1532-6500 |
| DOI: | 10.1016/j.jse.2015.03.010 |
| Online Access: | Verlag, Volltext: http://dx.doi.org/10.1016/j.jse.2015.03.010 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1058274615001342 |
| Author Notes: | Christian Ries, Marcel Müller, Kilian Wegmann, Doreen B. Pfau, Lars P. Müller, Klaus J. Burkhart |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 157130259X | ||
| 003 | DE-627 | ||
| 005 | 20220814095903.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180321s2015 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jse.2015.03.010 |2 doi | |
| 035 | |a (DE-627)157130259X | ||
| 035 | |a (DE-576)50130259X | ||
| 035 | |a (DE-599)BSZ50130259X | ||
| 035 | |a (OCoLC)1340994292 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Ries, Christian |e VerfasserIn |0 (DE-588)1154893995 |0 (DE-627)1016238398 |0 (DE-576)50130293X |4 aut | |
| 245 | 1 | 0 | |a Is an extension of the safe zone possible without jeopardizing the proximal radioulnar joint when performing a radial head plate osteosynthesis? |c Christian Ries, Marcel Müller, Kilian Wegmann, Doreen B. Pfau, Lars P. Müller, Klaus J. Burkhart |
| 264 | 1 | |c October 2015 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 21.03.2018 | ||
| 520 | |a Background: Proximal radial fractures are common elbow injuries. Because of the fracture pattern, stability criteria, or plate configuration, a plate position outside the “safe zone” (SZ) may be required in some cases when performing a radial head plate osteosynthesis. We examined the gross anatomy of the radial head and analyzed different so-called low-profile and precontoured radial head and neck plates with respect to the SZ. Materials and methods: Macroscopic measurements of the radial head and neck of 22 formalin-fixed human cadaveric upper extremities were obtained. The SZ was determined by maximum forearm rotation. If the edge of a plate could be extended beyond the respective SZ boundary without jeopardizing the proximal radioulnar joint (PRUJ) in maximum forearm rotation, a new plate-specific SZ boundary was set. Results: The mean SZ was 133° (SD, 14°). Among the 5 plates studied, only the 2 radial neck designs allowed the anterior edge of the plate to partially pass the lesser sigmoid notch of the ulna and consequently afforded a significant extension of the SZ in maximum pronation. All 3 radial head designs had to remain within the SZ to avoid interference with the PRUJ. A safe plate position depends on individual plate dimensions, particularly the proximal plate width, and the diameter of the radial head. The smaller the head diameter, the more accurately a plate must be placed within the SZ. Conclusions: If an extension of the SZ in radial head plate osteosynthesis is not essential, we recommend respecting the SZ to minimize the possibility of interference with the PRUJ. | ||
| 650 | 4 | |a fracture | |
| 650 | 4 | |a plate osteosynthesis | |
| 650 | 4 | |a Radial head | |
| 650 | 4 | |a safe zone | |
| 700 | 1 | |a Pfau, Doreen |d 1981- |e VerfasserIn |0 (DE-588)133716589 |0 (DE-627)552682276 |0 (DE-576)300046472 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of shoulder and elbow surgery |d St. Louis, Mo. : Mosby, 1992 |g 24(2015), 10, Seite 1627-1634 |h Online-Ressource |w (DE-627)32927029X |w (DE-600)2046901-9 |w (DE-576)09442716X |x 1532-6500 |7 nnas |a Is an extension of the safe zone possible without jeopardizing the proximal radioulnar joint when performing a radial head plate osteosynthesis? |
| 773 | 1 | 8 | |g volume:24 |g year:2015 |g number:10 |g pages:1627-1634 |g extent:8 |a Is an extension of the safe zone possible without jeopardizing the proximal radioulnar joint when performing a radial head plate osteosynthesis? |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jse.2015.03.010 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S1058274615001342 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180321 | ||
| 993 | |a Article | ||
| 994 | |a 2015 | ||
| 998 | |g 133716589 |a Pfau, Doreen |m 133716589:Pfau, Doreen |d 60000 |d 999810 |e 60000PP133716589 |e 999810PP133716589 |k 0/60000/ |k 1/60000/999810/ |p 4 | ||
| 999 | |a KXP-PPN157130259X |e 3003850024 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"name":{"displayForm":["Christian Ries, Marcel Müller, Kilian Wegmann, Doreen B. Pfau, Lars P. Müller, Klaus J. Burkhart"]},"id":{"eki":["157130259X"],"doi":["10.1016/j.jse.2015.03.010"]},"origin":[{"dateIssuedDisp":"October 2015","dateIssuedKey":"2015"}],"relHost":[{"title":[{"title_sort":"Journal of shoulder and elbow surgery","title":"Journal of shoulder and elbow surgery"}],"note":["Gesehen am 19.02.20"],"disp":"Is an extension of the safe zone possible without jeopardizing the proximal radioulnar joint when performing a radial head plate osteosynthesis?Journal of shoulder and elbow surgery","type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"recId":"32927029X","pubHistory":["1.1992 -"],"part":{"text":"24(2015), 10, Seite 1627-1634","volume":"24","extent":"8","year":"2015","issue":"10","pages":"1627-1634"},"origin":[{"publisherPlace":"St. Louis, Mo.","dateIssuedKey":"1992","publisher":"Mosby","dateIssuedDisp":"1992-"}],"id":{"zdb":["2046901-9"],"eki":["32927029X"],"issn":["1532-6500"]},"physDesc":[{"extent":"Online-Ressource"}]}],"physDesc":[{"extent":"8 S."}],"person":[{"role":"aut","roleDisplay":"VerfasserIn","display":"Ries, Christian","given":"Christian","family":"Ries"},{"roleDisplay":"VerfasserIn","display":"Pfau, Doreen","role":"aut","family":"Pfau","given":"Doreen"}],"title":[{"title_sort":"Is an extension of the safe zone possible without jeopardizing the proximal radioulnar joint when performing a radial head plate osteosynthesis?","title":"Is an extension of the safe zone possible without jeopardizing the proximal radioulnar joint when performing a radial head plate osteosynthesis?"}],"language":["eng"],"recId":"157130259X","type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 21.03.2018"]} | ||
| SRT | |a RIESCHRISTISANEXTENS2015 | ||