Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 tesla
Purpose: To compare the image quality of modern 3 D and 2 D sequences for dedicated wrist imaging at 3 Tesla (T) MRI. Materials and Methods: At 3 T MRI, 18 patients (mean age: 36.2 years) with wrist pain and 16 healthy volunteers (mean age: 26.4 years) were examined using 2 D proton density-weighted...
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
3 May 2016
|
| In: |
RöFo
Year: 2016, Jahrgang: 188, Heft: 8, Pages: 753-762 |
| ISSN: | 1438-9010 |
| DOI: | 10.1055/s-0042-104512 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1055/s-0042-104512 Verlag, Volltext: http://www.thieme-connect.de/DOI/DOI?10.1055/s-0042-104512 |
| Verfasserangaben: | C. Rehnitz, B. Klaan, F. von Stillfried, E. Amarteifio, I. Burkholder, H.U. Kauczor, M.A. Weber |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1571478922 | ||
| 003 | DE-627 | ||
| 005 | 20220814102221.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180327s2016 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1055/s-0042-104512 |2 doi | |
| 035 | |a (DE-627)1571478922 | ||
| 035 | |a (DE-576)501478922 | ||
| 035 | |a (DE-599)BSZ501478922 | ||
| 035 | |a (OCoLC)1340997740 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Rehnitz, Christoph |d 1976- |e VerfasserIn |0 (DE-588)140996990 |0 (DE-627)62381627X |0 (DE-576)321717368 |4 aut | |
| 245 | 1 | 0 | |a Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 tesla |c C. Rehnitz, B. Klaan, F. von Stillfried, E. Amarteifio, I. Burkholder, H.U. Kauczor, M.A. Weber |
| 264 | 1 | |c 3 May 2016 | |
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 27.03.2018 | ||
| 520 | |a Purpose: To compare the image quality of modern 3 D and 2 D sequences for dedicated wrist imaging at 3 Tesla (T) MRI. Materials and Methods: At 3 T MRI, 18 patients (mean age: 36.2 years) with wrist pain and 16 healthy volunteers (mean age: 26.4 years) were examined using 2 D proton density-weighted fat-saturated (PDfs), isotropic 3 D TrueFISP, 3 D MEDIC, and 3 D PDfs SPACE sequences. Image quality was rated on a five-point scale (0 - 4) including overall image quality (OIQ), visibility of important structures (cartilage, ligaments, TFCC) and degree of artifacts. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) of cartilage/bone/muscle/fluid as well as the mean overall SNR/CNR were calculated using region-of-interest analysis. ANOVA, paired t-, and Wilcoxon-signed-rank tests were applied. Results: The image quality of all tested sequences was superior to 3 D PDfs SPACE (p < 0.01). 3 D TrueFISP had the highest combined cartilage score (mean: 3.4) and performed better in cartilage comparisons against 3 D PDfs SPACE in both groups and 2 D PDfs in volunteers (p < 0.05). 3 D MEDIC performed better in 7 of 8 comparisons (p < 0.05) regarding ligaments and TFCC. 2 D PDfs provided constantly high scores. The mean overall SNR/CNR for 2 D PDfs, 3 D PDfs SPACE, 3 D TrueFISP, and 3 D MEDIC were 68/65, 32/27, 45/47, and 57/45, respectively. 2 D PDfs performed best in most SNR/CNR comparisons (p < 0.05) and 3 D MEDIC performed best within the 3 D sequences (p < 0.05). Conclusion: Except 3 D PDfs SPACE, all tested 3 D and 2 D sequences provided high image quality. 3 D TrueFISP was best for cartilage imaging, 3 D MEDIC for ligaments and TFCC and 2 D PDfs for general wrist imaging. Key points: 3 D TrueFISP is recommended for cartilage imaging of the wrist at 3 T. 3 D MEDIC is recommended for ligaments and TFCC. Robust 2 D PDfs should be used in routine protocols. 3 D sequences may be added depending on the clinical question. 3 D PDfs SPACE is currently inferior. Citation Format: Rehnitz C, Klaan B, von Stillfried F et al. Comparison of Modern 3D and 2D MR Imaging Sequences of the Wrist at 3 Tesla. Fortschr Röntgenstr 2016; 188: 753 - 762 | ||
| 700 | 1 | |a Klaan, Bastian |d 1985- |e VerfasserIn |0 (DE-588)1155202813 |0 (DE-627)1016543999 |0 (DE-576)501478876 |4 aut | |
| 700 | 1 | |a Stillfried, Falko von |e VerfasserIn |0 (DE-588)1125660554 |0 (DE-627)880324007 |0 (DE-576)483540455 |4 aut | |
| 700 | 1 | |a Amarteifio, Erick |d 1981- |e VerfasserIn |0 (DE-588)137370377 |0 (DE-627)695066714 |0 (DE-576)30320902X |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Weber, Marc-André |d 1973- |e VerfasserIn |0 (DE-588)142373044 |0 (DE-627)704211432 |0 (DE-576)330376802 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t RöFo |d Stuttgart [u.a.] : Thieme, 1975 |g 188(2016), 8, Seite 753-762 |h Online-Ressource |w (DE-627)324825021 |w (DE-600)2031079-1 |w (DE-576)107736748 |x 1438-9010 |7 nnas |a Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 tesla |
| 773 | 1 | 8 | |g volume:188 |g year:2016 |g number:8 |g pages:753-762 |g extent:10 |a Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 tesla |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1055/s-0042-104512 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.thieme-connect.de/DOI/DOI?10.1055/s-0042-104512 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180327 | ||
| 993 | |a Article | ||
| 994 | |a 2016 | ||
| 998 | |g 142373044 |a Weber, Marc-André |m 142373044:Weber, Marc-André |d 910000 |d 911400 |e 910000PW142373044 |e 911400PW142373044 |k 0/910000/ |k 1/910000/911400/ |p 7 |y j | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 6 | ||
| 998 | |g 137370377 |a Amarteifio, Erick |m 137370377:Amarteifio, Erick |d 910000 |d 911400 |e 910000PA137370377 |e 911400PA137370377 |k 0/910000/ |k 1/910000/911400/ |p 4 | ||
| 998 | |g 1125660554 |a Stillfried, Falko von |m 1125660554:Stillfried, Falko von |d 910000 |d 911460 |e 910000PS1125660554 |e 911460PS1125660554 |k 0/910000/ |k 1/910000/911460/ |p 3 | ||
| 998 | |g 1155202813 |a Klaan, Bastian |m 1155202813:Klaan, Bastian |d 910000 |d 911400 |e 910000PK1155202813 |e 911400PK1155202813 |k 0/910000/ |k 1/910000/911400/ |p 2 | ||
| 998 | |g 140996990 |a Rehnitz, Christoph |m 140996990:Rehnitz, Christoph |d 910000 |d 911400 |e 910000PR140996990 |e 911400PR140996990 |k 0/910000/ |k 1/910000/911400/ |p 1 |x j | ||
| 999 | |a KXP-PPN1571478922 |e 3004383101 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 27.03.2018"],"title":[{"title_sort":"Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 tesla","title":"Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 tesla"}],"origin":[{"dateIssuedKey":"2016","dateIssuedDisp":"3 May 2016"}],"person":[{"family":"Rehnitz","given":"Christoph","role":"aut","display":"Rehnitz, Christoph"},{"display":"Klaan, Bastian","role":"aut","given":"Bastian","family":"Klaan"},{"given":"Falko von","role":"aut","family":"Stillfried","display":"Stillfried, Falko von"},{"display":"Amarteifio, Erick","given":"Erick","role":"aut","family":"Amarteifio"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","given":"Hans-Ulrich","role":"aut"},{"display":"Weber, Marc-André","family":"Weber","given":"Marc-André","role":"aut"}],"relHost":[{"part":{"pages":"753-762","extent":"10","text":"188(2016), 8, Seite 753-762","issue":"8","year":"2016","volume":"188"},"id":{"eki":["324825021"],"issn":["1438-9010"],"zdb":["2031079-1"],"doi":["10.1055/s-00000066"]},"pubHistory":["122.1975 -"],"titleAlt":[{"title":"RöFo vereinigt mit Aktuelle Radiologie"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin"},{"title":"Fortschritte auf dem Gebiete der Röntgenstrahlen und der neuen bildgebenden Verfahren"}],"disp":"Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 teslaRöFo","physDesc":[{"extent":"Online-Ressource"}],"recId":"324825021","note":["Gesehen am 20.03.2023"],"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["ger"],"title":[{"subtitle":"Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren","title_sort":"RöFo","title":"RöFo"}],"origin":[{"publisherPlace":"Stuttgart [u.a.]","dateIssuedKey":"1975","dateIssuedDisp":"1975-","publisher":"Thieme"}]}],"physDesc":[{"extent":"10 S."}],"recId":"1571478922","id":{"eki":["1571478922"],"doi":["10.1055/s-0042-104512"]},"name":{"displayForm":["C. Rehnitz, B. Klaan, F. von Stillfried, E. Amarteifio, I. Burkholder, H.U. Kauczor, M.A. Weber"]}} | ||
| SRT | |a REHNITZCHRCOMPARISON3201 | ||