Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy Center

The introduction of 'new' ion species in particle therapy needs to be supported by a thorough assessment of their dosimetric properties and by treatment planning comparisons with clinically used proton and carbon ion beams. In addition to the latter two ions, helium and oxygen ion beams ar...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Tessonnier, Thomas (VerfasserIn) , Brons, Stephan (VerfasserIn) , Haberer, Thomas (VerfasserIn) , Debus, Jürgen (VerfasserIn) , Parodi, Katia (VerfasserIn) , Mairani, Andrea (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 31 July 2017
In: Physics in medicine and biology
Year: 2017, Jahrgang: 62, Heft: 16, Pages: 6579-6594
ISSN:1361-6560
DOI:10.1088/1361-6560/aa7be4
Online-Zugang:Verlag, Pay-per-use, Volltext: http://dx.doi.org/10.1088/1361-6560/aa7be4
Volltext
Verfasserangaben:T. Tessonnier, T. T. Boehlen, F. Ceruti, A. Ferrari, P. Sala, S. Brons, T. Haberer, J. Debus, K. Parodi and A. Mairani

MARC

LEADER 00000caa a2200000 c 4500
001 1571664106
003 DE-627
005 20230426124229.0
007 cr uuu---uuuuu
008 180403s2017 xx |||||o 00| ||eng c
024 7 |a 10.1088/1361-6560/aa7be4  |2 doi 
035 |a (DE-627)1571664106 
035 |a (DE-576)501664106 
035 |a (DE-599)BSZ501664106 
035 |a (OCoLC)1341001533 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Tessonnier, Thomas  |e VerfasserIn  |0 (DE-588)1075079195  |0 (DE-627)83292685X  |0 (DE-576)443252270  |4 aut 
245 1 0 |a Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy Center  |c T. Tessonnier, T. T. Boehlen, F. Ceruti, A. Ferrari, P. Sala, S. Brons, T. Haberer, J. Debus, K. Parodi and A. Mairani 
264 1 |c 31 July 2017 
300 |a 16 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 03.04.2018 
520 |a The introduction of 'new' ion species in particle therapy needs to be supported by a thorough assessment of their dosimetric properties and by treatment planning comparisons with clinically used proton and carbon ion beams. In addition to the latter two ions, helium and oxygen ion beams are foreseen at the Heidelberg Ion Beam Therapy Center (HIT) as potential assets for improving clinical outcomes in the near future. We present in this study a dosimetric validation of a FLUKA-based Monte Carlo treatment planning tool (MCTP) for protons, helium, carbon and oxygen ions for spread-out Bragg peaks in water. The comparisons between the ions show the dosimetric advantages of helium and heavier ion beams in terms of their distal and lateral fall-offs with respect to protons, reducing the lateral size of the region receiving 50% of the planned dose up to 12 mm. However, carbon and oxygen ions showed significant doses beyond the target due to the higher fragmentation tail compared to lighter ions (p and He), up to 25%. The Monte Carlo predictions were found to be in excellent geometrical agreement with the measurements, with deviations below 1 mm for all parameters investigated such as target and lateral size as well as distal fall-offs. Measured and simulated absolute dose values agreed within about 2.5% on the overall dose distributions. The MCTP tool, which supports the usage of multiple state-of-the-art relative biological effectiveness models, will provide a solid engine for treatment planning comparisons at HIT. 
650 4 |a c-12 
650 4 |a dose distributions 
650 4 |a experimental comparisons 
650 4 |a fluka 
650 4 |a h-1 
650 4 |a he-4 
650 4 |a implementation 
650 4 |a microdosimetric kinetic-model 
650 4 |a Monte Carlo 
650 4 |a particle therapy 
650 4 |a radiotherapy 
650 4 |a relative biological effectiveness 
650 4 |a scanned proton 
650 4 |a sobp 
650 4 |a treatment planning 
700 1 |a Brons, Stephan  |e VerfasserIn  |0 (DE-588)1072782375  |0 (DE-627)828233594  |0 (DE-576)434240478  |4 aut 
700 1 |a Haberer, Thomas  |d 1960-  |e VerfasserIn  |0 (DE-588)123579198  |0 (DE-627)706353714  |0 (DE-576)214902188  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Parodi, Katia  |d 1975-  |e VerfasserIn  |0 (DE-588)129736996  |0 (DE-627)707308917  |0 (DE-576)188641688  |4 aut 
700 1 |a Mairani, Andrea  |e VerfasserIn  |0 (DE-588)1116742179  |0 (DE-627)870669281  |0 (DE-576)478592493  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 62(2017), 16, Seite 6579-6594  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy Center 
773 1 8 |g volume:62  |g year:2017  |g number:16  |g pages:6579-6594  |g extent:16  |a Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy Center 
856 4 0 |u http://dx.doi.org/10.1088/1361-6560/aa7be4  |x Verlag  |x Resolving-System  |z Pay-per-use  |3 Volltext 
951 |a AR 
992 |a 20180403 
993 |a Article 
994 |a 2017 
998 |g 1116742179  |a Mairani, Andrea  |m 1116742179:Mairani, Andrea  |d 910000  |d 950000  |d 950400  |e 910000PM1116742179  |e 950000PM1116742179  |e 950400PM1116742179  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 10  |y j 
998 |g 129736996  |a Parodi, Katia  |m 129736996:Parodi, Katia  |p 9 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 123579198  |a Haberer, Thomas  |m 123579198:Haberer, Thomas  |d 910000  |d 950000  |d 950400  |e 910000PH123579198  |e 950000PH123579198  |e 950400PH123579198  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 7 
998 |g 1072782375  |a Brons, Stephan  |m 1072782375:Brons, Stephan  |d 910000  |d 950000  |d 950400  |e 910000PB1072782375  |e 950000PB1072782375  |e 950400PB1072782375  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 6 
998 |g 1075079195  |a Tessonnier, Thomas  |m 1075079195:Tessonnier, Thomas  |p 1  |x j 
999 |a KXP-PPN1571664106  |e 3004807890 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"id":{"issn":["1361-6560"],"eki":["269016163"],"zdb":["1473501-5"]},"physDesc":[{"extent":"Online-Ressource"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy CenterPhysics in medicine and biology","origin":[{"publisherPlace":"Bristol","dateIssuedKey":"1956","publisher":"IOP Publ.","dateIssuedDisp":"1956-"}],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"recId":"269016163","title":[{"title_sort":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology"}],"pubHistory":["1.1956 -"],"language":["eng"],"part":{"extent":"16","volume":"62","year":"2017","pages":"6579-6594","issue":"16","text":"62(2017), 16, Seite 6579-6594"}}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"31 July 2017"}],"id":{"eki":["1571664106"],"doi":["10.1088/1361-6560/aa7be4"]},"title":[{"title":"Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy Center","title_sort":"Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy Center"}],"language":["eng"],"note":["Gesehen am 03.04.2018"],"recId":"1571664106","physDesc":[{"extent":"16 S."}],"person":[{"role":"aut","roleDisplay":"VerfasserIn","family":"Tessonnier","given":"Thomas","display":"Tessonnier, Thomas"},{"family":"Brons","given":"Stephan","display":"Brons, Stephan","roleDisplay":"VerfasserIn","role":"aut"},{"display":"Haberer, Thomas","given":"Thomas","family":"Haberer","role":"aut","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","role":"aut","given":"Jürgen","family":"Debus","display":"Debus, Jürgen"},{"roleDisplay":"VerfasserIn","role":"aut","given":"Katia","family":"Parodi","display":"Parodi, Katia"},{"display":"Mairani, Andrea","given":"Andrea","family":"Mairani","role":"aut","roleDisplay":"VerfasserIn"}],"name":{"displayForm":["T. Tessonnier, T. T. Boehlen, F. Ceruti, A. Ferrari, P. Sala, S. Brons, T. Haberer, J. Debus, K. Parodi and A. Mairani"]}} 
SRT |a TESSONNIERDOSIMETRIC3120