Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes

Proton beam therapy is promising for the treatment of head and neck cancer (HNC), but it is sensitive to uncertainties in patient positioning and particle range. Studies have shown that the planning target volume (PTV) concept may not be sufficient to ensure robustness of the target coverage. A few...

Full description

Saved in:
Bibliographic Details
Main Authors: Cubillos Mesías, Macarena (Author) , Troost, Esther Gera Cornelia (Author) , Lohaus, Fabian (Author) , Löck, Steffen (Author) , Richter, Christian (Author) , Stützer, Kristin (Author)
Format: Article (Journal)
Language:English
Published: 28 November 2017
In: Radiation oncology
Year: 2017, Volume: 12
ISSN:1748-717X
DOI:10.1186/s13014-017-0931-8
Online Access:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1186/s13014-017-0931-8
Verlag, Volltext: https://doi.org/10.1186/s13014-017-0931-8
Get full text
Author Notes:Macarena Cubillos-Mesías, Michael Baumann, Esther G.C. Troost, Fabian Lohaus, Steffen Löck, Christian Richter and Kristin Stützer

MARC

LEADER 00000caa a2200000 c 4500
001 1571922547
003 DE-627
005 20220814111815.0
007 cr uuu---uuuuu
008 180411s2017 xx |||||o 00| ||eng c
024 7 |a 10.1186/s13014-017-0931-8  |2 doi 
035 |a (DE-627)1571922547 
035 |a (DE-576)501922547 
035 |a (DE-599)BSZ501922547 
035 |a (OCoLC)1341002069 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Cubillos Mesías, Macarena  |d 1985-  |e VerfasserIn  |0 (DE-588)1096363976  |0 (DE-627)856744182  |0 (DE-576)468014241  |4 aut 
245 1 0 |a Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes  |c Macarena Cubillos-Mesías, Michael Baumann, Esther G.C. Troost, Fabian Lohaus, Steffen Löck, Christian Richter and Kristin Stützer 
264 1 |c 28 November 2017 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 11.04.2018 
520 |a Proton beam therapy is promising for the treatment of head and neck cancer (HNC), but it is sensitive to uncertainties in patient positioning and particle range. Studies have shown that the planning target volume (PTV) concept may not be sufficient to ensure robustness of the target coverage. A few planning studies have considered irradiation of unilateral HNC targets with protons, but they have only taken into account the dose on the nominal plan, without considering anatomy changes occurring during the treatment course. 
650 4 |a Adaptive radiation therapy 
650 4 |a Head and neck cancer 
650 4 |a Multi-field optimization 
650 4 |a Proton therapy 
650 4 |a Robust optimization 
650 4 |a Single-field optimization 
700 1 |a Troost, Esther Gera Cornelia  |d 1978-  |e VerfasserIn  |0 (DE-588)135713250  |0 (DE-627)570561221  |0 (DE-576)300603169  |4 aut 
700 1 |a Lohaus, Fabian  |e VerfasserIn  |4 aut 
700 1 |a Löck, Steffen  |d 1982-  |e VerfasserIn  |0 (DE-588)141342943  |0 (DE-627)626890551  |0 (DE-576)323124631  |4 aut 
700 1 |a Richter, Christian  |d 1981-  |e VerfasserIn  |0 (DE-588)1044099852  |0 (DE-627)771544952  |0 (DE-576)396715885  |4 aut 
700 1 |a Stützer, Kristin  |d 1982-  |e VerfasserIn  |0 (DE-588)1047433389  |0 (DE-627)778296342  |0 (DE-576)401023877  |4 aut 
773 0 8 |i Enthalten in  |t Radiation oncology  |d London : BioMed Central, 2006  |g 12(2017) Artikel-Nummer 190, 10 Seiten  |h Online-Ressource  |w (DE-627)508725739  |w (DE-600)2224965-5  |w (DE-576)260614815  |x 1748-717X  |7 nnas  |a Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes 
773 1 8 |g volume:12  |g year:2017  |g extent:10  |a Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes 
856 4 0 |u http://dx.doi.org/10.1186/s13014-017-0931-8  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://doi.org/10.1186/s13014-017-0931-8  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180411 
993 |a Article 
994 |a 2017 
998 |g 1047433389  |a Stützer, Kristin  |m 1047433389:Stützer, Kristin  |d 910000  |e 910000PS1047433389  |k 0/910000/  |p 7  |y j 
998 |g 1044099852  |a Richter, Christian  |m 1044099852:Richter, Christian  |d 910000  |e 910000PR1044099852  |k 0/910000/  |p 6 
998 |g 135713250  |a Troost, Esther Gera Cornelia  |m 135713250:Troost, Esther Gera Cornelia  |p 3 
999 |a KXP-PPN1571922547  |e 3005821986 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 11.04.2018"],"language":["eng"],"recId":"1571922547","title":[{"title_sort":"Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes","title":"Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumes"}],"person":[{"role":"aut","display":"Cubillos Mesías, Macarena","roleDisplay":"VerfasserIn","given":"Macarena","family":"Cubillos Mesías"},{"family":"Troost","given":"Esther Gera Cornelia","roleDisplay":"VerfasserIn","display":"Troost, Esther Gera Cornelia","role":"aut"},{"given":"Fabian","family":"Lohaus","role":"aut","roleDisplay":"VerfasserIn","display":"Lohaus, Fabian"},{"roleDisplay":"VerfasserIn","display":"Löck, Steffen","role":"aut","family":"Löck","given":"Steffen"},{"family":"Richter","given":"Christian","display":"Richter, Christian","roleDisplay":"VerfasserIn","role":"aut"},{"given":"Kristin","family":"Stützer","role":"aut","roleDisplay":"VerfasserIn","display":"Stützer, Kristin"}],"physDesc":[{"extent":"10 S."}],"relHost":[{"title":[{"title":"Radiation oncology","title_sort":"Radiation oncology"}],"part":{"extent":"10","volume":"12","text":"12(2017) Artikel-Nummer 190, 10 Seiten","year":"2017"},"pubHistory":["1.2006 -"],"recId":"508725739","language":["eng"],"note":["Gesehen am 06.09.10"],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"Impact of robust treatment planning on single- and multi-field optimized plans for proton beam therapy of unilateral head and neck target volumesRadiation oncology","id":{"zdb":["2224965-5"],"eki":["508725739"],"issn":["1748-717X"]},"origin":[{"publisherPlace":"London","dateIssuedDisp":"2006-","dateIssuedKey":"2006","publisher":"BioMed Central"}],"physDesc":[{"extent":"Online-Ressource"}]}],"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"28 November 2017"}],"id":{"eki":["1571922547"],"doi":["10.1186/s13014-017-0931-8"]},"name":{"displayForm":["Macarena Cubillos-Mesías, Michael Baumann, Esther G.C. Troost, Fabian Lohaus, Steffen Löck, Christian Richter and Kristin Stützer"]}} 
SRT |a CUBILLOSMEIMPACTOFRO2820