Tourniquet application during TKA did not affect the accuracy of implant positioning: a randomized clinical trial

PurposeThe accuracy of the identification of anatomical landmarks with versus without tourniquet application and its effect on implant positioning remained unknown. Therefore, the hypothesis of the present study was that tourniquet application did not affect the accuracy of the reconstruction of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Stetzelberger, Vera (VerfasserIn) , Obertacke, Udo (VerfasserIn) , Jawhar, Ahmed (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2018
In: Knee surgery, sports traumatology, arthroscopy
Year: 2018, Jahrgang: 26, Heft: 6, Pages: 1728-1736
ISSN:1433-7347
DOI:10.1007/s00167-017-4760-y
Online-Zugang:Verlag, Volltext: https://doi.org/10.1007/s00167-017-4760-y
Volltext
Verfasserangaben:Vera Stetzelberger, Udo Obertacke, Ahmed Jawhar

MARC

LEADER 00000caa a2200000 c 4500
001 1572167416
003 DE-627
005 20220824160115.0
007 cr uuu---uuuuu
008 180419s2018 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00167-017-4760-y  |2 doi 
035 |a (DE-627)1572167416 
035 |a (DE-576)502167416 
035 |a (DE-599)BSZ502167416 
035 |a (OCoLC)1341007374 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Stetzelberger, Vera  |d 1993-  |e VerfasserIn  |0 (DE-588)1156408911  |0 (DE-627)1019236434  |0 (DE-576)502163933  |4 aut 
245 1 0 |a Tourniquet application during TKA did not affect the accuracy of implant positioning  |b a randomized clinical trial  |c Vera Stetzelberger, Udo Obertacke, Ahmed Jawhar 
264 1 |c 2018 
300 |a 9 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online: 20 October 2017 
500 |a Gesehen am 01.09.2020 
520 |a PurposeThe accuracy of the identification of anatomical landmarks with versus without tourniquet application and its effect on implant positioning remained unknown. Therefore, the hypothesis of the present study was that tourniquet application did not affect the accuracy of the reconstruction of the mechanical leg alignment, the joint line level, and the patellar height.MethodsThe prospective randomized monocentric trial (Clinical-Trials.gov NCT02475603) included a total of 86 patients scheduled to undergo primary TKA. The patients were allocated to receive TKA with (Group A, n = 43) or without tourniquet (Group B, n = 43). The mechanical leg alignment, the joint line level (modified Kawamura), and the patellar height (Plateau-patella angle, Insall Salvati index, and modified Insall Salvati index) were measured pre- and postoperatively on standardized calibrated digital radiographs. Mean, SEM, median, range, and p value were calculated for each parameter.ResultsThere was no statistical difference between the groups with regard to demographics, preoperative deformity, implant design, and surgical technique (n.s.). The mechanical leg alignment, the joint line level, and the patellar height revealed, in both groups, similar results pre- and postoperatively (n.s.).ConclusionThe mechanical leg alignment, the joint line level, and the patellar height could be accurately reconstructed with and without tourniquet use. With respect to clinically relevant surrogate parameters of implant positioning, TKA can safely be performed without a tourniquet. Available data do not support a routine use of tourniquet during TKA and might justify a change of the clinical pathway.Level of evidenceLevel I. 
700 1 |a Obertacke, Udo  |d 1957-  |e VerfasserIn  |0 (DE-588)1034338978  |0 (DE-627)745232590  |0 (DE-576)381955672  |4 aut 
700 1 |a Jawhar, Ahmed  |d 1983-  |e VerfasserIn  |0 (DE-588)1038724740  |0 (DE-627)766371832  |0 (DE-576)392760797  |4 aut 
773 0 8 |i Enthalten in  |t Knee surgery, sports traumatology, arthroscopy  |d Berlin : Springer, 1993  |g 26(2018), 6, Seite 1728-1736  |h Online-Ressource  |w (DE-627)268761787  |w (DE-600)1473170-8  |w (DE-576)094425191  |x 1433-7347  |7 nnas  |a Tourniquet application during TKA did not affect the accuracy of implant positioning a randomized clinical trial 
773 1 8 |g volume:26  |g year:2018  |g number:6  |g pages:1728-1736  |g extent:9  |a Tourniquet application during TKA did not affect the accuracy of implant positioning a randomized clinical trial 
856 4 0 |u https://doi.org/10.1007/s00167-017-4760-y  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180419 
993 |a Article 
994 |a 2018 
998 |g 1038724740  |a Jawhar, Ahmed  |m 1038724740:Jawhar, Ahmed  |d 60000  |d 62400  |e 60000PJ1038724740  |e 62400PJ1038724740  |k 0/60000/  |k 1/60000/62400/  |p 3  |y j 
998 |g 1034338978  |a Obertacke, Udo  |m 1034338978:Obertacke, Udo  |d 60000  |d 62400  |e 60000PO1034338978  |e 62400PO1034338978  |k 0/60000/  |k 1/60000/62400/  |p 2 
998 |g 1156408911  |a Stetzelberger, Vera  |m 1156408911:Stetzelberger, Vera  |d 60000  |d 62400  |e 60000PS1156408911  |e 62400PS1156408911  |k 0/60000/  |k 1/60000/62400/  |p 1  |x j 
999 |a KXP-PPN1572167416  |e 3006454286 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"9 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["268761787"],"zdb":["1473170-8"],"issn":["1433-7347"]},"origin":[{"dateIssuedKey":"1993","publisher":"Springer ; Springer","dateIssuedDisp":"1993-","publisherPlace":"Berlin ; Heidelberg ; Berlin ; Heidelberg ; New York, NY"}],"titleAlt":[{"title":"KSSTA"},{"title":"official journal of the ESSKA ; organ of ESSKA, European Society of Sports Traumatology, Knee Surgery and Arthroscopy"}],"part":{"text":"26(2018), 6, Seite 1728-1736","volume":"26","extent":"9","year":"2018","pages":"1728-1736","issue":"6"},"pubHistory":["1.1993 -"],"recId":"268761787","language":["eng"],"corporate":[{"role":"isb","roleDisplay":"Herausgebendes Organ","display":"European Society of Sports Traumatology, Knee Surgery and Arthroscopy"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Tourniquet application during TKA did not affect the accuracy of implant positioning a randomized clinical trialKnee surgery, sports traumatology, arthroscopy","note":["Erscheint unregelmäßig","Gesehen am 26.09.2024","Teils ungezählte Beil.: Supplement"],"title":[{"title_sort":"Knee surgery, sports traumatology, arthroscopy","subtitle":"KSSTA ; official journal of the European Society of Sports Traumatology, Knee Surgery and Arthroscopy (ESSKA)","title":"Knee surgery, sports traumatology, arthroscopy"}]}],"name":{"displayForm":["Vera Stetzelberger, Udo Obertacke, Ahmed Jawhar"]},"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"2018"}],"id":{"eki":["1572167416"],"doi":["10.1007/s00167-017-4760-y"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Published online: 20 October 2017","Gesehen am 01.09.2020"],"language":["eng"],"recId":"1572167416","person":[{"family":"Stetzelberger","given":"Vera","display":"Stetzelberger, Vera","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Obertacke, Udo","given":"Udo","family":"Obertacke"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Jawhar, Ahmed","given":"Ahmed","family":"Jawhar"}],"title":[{"subtitle":"a randomized clinical trial","title":"Tourniquet application during TKA did not affect the accuracy of implant positioning","title_sort":"Tourniquet application during TKA did not affect the accuracy of implant positioning"}]} 
SRT |a STETZELBERTOURNIQUET2018