Application of a dedicated surface coil in dental MRI provides superior image quality in comparison with a standard coil

Purpose: Purpose of our research was the evaluation of a dedicated dental surface coil in comparison with a standard head and neck coil for the improvement of dental magnetic resonance imaging (MRI).Materials and MethodsAxial T1-weighted spin echo MRI was performed by using a newly developed dental...

Full description

Saved in:
Bibliographic Details
Main Authors: Gradl, Joseph (Author) , Pfefferle, Thorsten (Author) , Prager, Marcel (Author) , Hilgenfeld, Tim (Author) , Bäumer, Philipp (Author) , Heiland, Sabine (Author) , Bendszus, Martin (Author) , Hähnel, Stefan (Author)
Format: Article (Journal)
Language:English
Published: 2017
In: Clinical neuroradiology
Year: 2017, Volume: 27, Issue: 3, Pages: 371-378
ISSN:1869-1447
DOI:10.1007/s00062-016-0500-9
Online Access:Verlag, Volltext: http://dx.doi.org/10.1007/s00062-016-0500-9
Verlag, Volltext: https://link.springer.com/article/10.1007/s00062-016-0500-9
Get full text
Author Notes:J. Gradl, M. Höreth, T. Pfefferle, M. Prager, T. Hilgenfeld, D. Gareis, P. Bäumer, S. Heiland, M. Bendszus, S. Hähnel

MARC

LEADER 00000caa a2200000 c 4500
001 157223959X
003 DE-627
005 20220814121528.0
007 cr uuu---uuuuu
008 180423s2017 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00062-016-0500-9  |2 doi 
035 |a (DE-627)157223959X 
035 |a (DE-576)50223959X 
035 |a (DE-599)BSZ50223959X 
035 |a (OCoLC)1341007532 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Gradl, Joseph  |e VerfasserIn  |0 (DE-588)11680744X  |0 (DE-627)078279615  |0 (DE-576)290847311  |4 aut 
245 1 0 |a Application of a dedicated surface coil in dental MRI provides superior image quality in comparison with a standard coil  |c J. Gradl, M. Höreth, T. Pfefferle, M. Prager, T. Hilgenfeld, D. Gareis, P. Bäumer, S. Heiland, M. Bendszus, S. Hähnel 
264 1 |c 2017 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 23.04.2018 
520 |a Purpose: Purpose of our research was the evaluation of a dedicated dental surface coil in comparison with a standard head and neck coil for the improvement of dental magnetic resonance imaging (MRI).Materials and MethodsAxial T1-weighted spin echo MRI was performed by using a newly developed dental coil for MRI and a standard head and neck coil on five volunteers. In addition, MRI was implemented with dental coil on five patients. Using the Wilcoxon test, we compared the volunteers’ signal-to-noise ratio (SNR) of a variety of anatomical structures (e.g., hard tooth tissue, pulp tissue, bone, muscle tissue). Also subjective evaluation of image quality was performed on both volunteers and patients.ResultsCompared with the head and neck coil, the mean SNR was 3.5-fold higher on an average with the dental coil (range: from 2.7 [masseter muscle] to 4.6 [pulp tissue]). That difference was statistically significant for all evaluated structures. The higher SNR also resulted in a superior image quality as determined by subjective evaluation.ConclusionDental MRI benefits profoundly from using a dedicated dental coil. 
700 1 |a Pfefferle, Thorsten  |d 1979-  |e VerfasserIn  |0 (DE-588)138823103  |0 (DE-627)606152008  |0 (DE-576)309252628  |4 aut 
700 1 |a Prager, Marcel  |e VerfasserIn  |0 (DE-588)1106261631  |0 (DE-627)86295357X  |0 (DE-576)473950030  |4 aut 
700 1 |a Hilgenfeld, Tim  |d 1986-  |e VerfasserIn  |0 (DE-588)1106261917  |0 (DE-627)862954398  |0 (DE-576)473950316  |4 aut 
700 1 |a Bäumer, Philipp  |d 1981-  |e VerfasserIn  |0 (DE-588)138369836  |0 (DE-627)696555735  |0 (DE-576)307128032  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Hähnel, Stefan  |d 1966-  |e VerfasserIn  |0 (DE-588)113981937  |0 (DE-627)558821138  |0 (DE-576)289781639  |4 aut 
773 0 8 |i Enthalten in  |t Clinical neuroradiology  |d München : Urban & Vogel, 2006  |g 27(2017), 3, Seite 371-378  |h Online-Ressource  |w (DE-627)510935257  |w (DE-600)2232347-8  |w (DE-576)252954327  |x 1869-1447  |7 nnas  |a Application of a dedicated surface coil in dental MRI provides superior image quality in comparison with a standard coil 
773 1 8 |g volume:27  |g year:2017  |g number:3  |g pages:371-378  |g extent:8  |a Application of a dedicated surface coil in dental MRI provides superior image quality in comparison with a standard coil 
856 4 0 |u http://dx.doi.org/10.1007/s00062-016-0500-9  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://link.springer.com/article/10.1007/s00062-016-0500-9  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180423 
993 |a Article 
994 |a 2017 
998 |g 113981937  |a Hähnel, Stefan  |m 113981937:Hähnel, Stefan  |d 910000  |d 911100  |e 910000PH113981937  |e 911100PH113981937  |k 0/910000/  |k 1/910000/911100/  |p 10  |y j 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 9 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 8 
998 |g 138369836  |a Bäumer, Philipp  |m 138369836:Bäumer, Philipp  |d 50000  |e 50000PB138369836  |k 0/50000/  |p 7 
998 |g 1106261917  |a Hilgenfeld, Tim  |m 1106261917:Hilgenfeld, Tim  |d 910000  |d 911100  |e 910000PH1106261917  |e 911100PH1106261917  |k 0/910000/  |k 1/910000/911100/  |p 5 
998 |g 1106261631  |a Prager, Marcel  |m 1106261631:Prager, Marcel  |d 60000  |d 63000  |e 60000PP1106261631  |e 63000PP1106261631  |k 0/60000/  |k 1/60000/63000/  |p 4 
998 |g 138823103  |a Pfefferle, Thorsten  |m 138823103:Pfefferle, Thorsten  |d 910000  |d 910800  |e 910000PP138823103  |e 910800PP138823103  |k 0/910000/  |k 1/910000/910800/  |p 3 
999 |a KXP-PPN157223959X  |e 3006757521 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"display":"Gradl, Joseph","family":"Gradl","role":"aut","given":"Joseph"},{"family":"Pfefferle","role":"aut","given":"Thorsten","display":"Pfefferle, Thorsten"},{"given":"Marcel","role":"aut","family":"Prager","display":"Prager, Marcel"},{"family":"Hilgenfeld","given":"Tim","role":"aut","display":"Hilgenfeld, Tim"},{"display":"Bäumer, Philipp","given":"Philipp","role":"aut","family":"Bäumer"},{"role":"aut","given":"Sabine","family":"Heiland","display":"Heiland, Sabine"},{"display":"Bendszus, Martin","family":"Bendszus","given":"Martin","role":"aut"},{"given":"Stefan","role":"aut","family":"Hähnel","display":"Hähnel, Stefan"}],"relHost":[{"recId":"510935257","physDesc":[{"extent":"Online-Ressource"}],"disp":"Application of a dedicated surface coil in dental MRI provides superior image quality in comparison with a standard coilClinical neuroradiology","origin":[{"dateIssuedKey":"2006","dateIssuedDisp":"2006-","publisherPlace":"München","publisher":"Urban & Vogel"}],"pubHistory":["16.2006 -"],"id":{"zdb":["2232347-8"],"eki":["510935257"],"issn":["1869-1447","1615-6706"]},"title":[{"subtitle":"official publication of the German, Austrian and Swiss societies of neuroradiology","title_sort":"Clinical neuroradiology","title":"Clinical neuroradiology"}],"part":{"text":"27(2017), 3, Seite 371-378","extent":"8","issue":"3","pages":"371-378","volume":"27","year":"2017"},"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 27.09.2018"]}],"origin":[{"dateIssuedDisp":"2017","dateIssuedKey":"2017"}],"note":["Gesehen am 23.04.2018"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"title":[{"title_sort":"Application of a dedicated surface coil in dental MRI provides superior image quality in comparison with a standard coil","title":"Application of a dedicated surface coil in dental MRI provides superior image quality in comparison with a standard coil"}],"physDesc":[{"extent":"8 S."}],"recId":"157223959X","name":{"displayForm":["J. Gradl, M. Höreth, T. Pfefferle, M. Prager, T. Hilgenfeld, D. Gareis, P. Bäumer, S. Heiland, M. Bendszus, S. Hähnel"]},"id":{"eki":["157223959X"],"doi":["10.1007/s00062-016-0500-9"]}} 
SRT |a GRADLJOSEPAPPLICATIO2017