Safety and efficacy of MitraClipTM therapy in patients with severely impaired left ventricular ejection fraction: results from the German transcatheter mitral valve interventions (TRAMI) registry

Aims The aim of the present study was to assess the safety and efficacy of percutaneous mitral valve repair using the MitraClip™ device in patients with severely reduced systolic left ventricular (LV) function. Methods and results Among 777 MitraClip™ implantations included in the German mitral valv...

Full description

Saved in:
Bibliographic Details
Main Authors: Geis, Nicolas (Author) , Katus, Hugo (Author) , Bekeredjian, Raffi (Author)
Format: Article (Journal)
Language:English
Published: 2018
In: European journal of heart failure
Year: 2017, Volume: 20, Issue: 3, Pages: 598-608
ISSN:1879-0844
DOI:10.1002/ejhf.910
Online Access:Verlag, Volltext: http://dx.doi.org/10.1002/ejhf.910
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/ejhf.910
Get full text
Author Notes:Nicolas A. Geis, Miriam Puls, Edith Lubos, Christine S. Zuern, Jennifer Franke, Robert Schueler, Ralph S. von Bardeleben, Peter Boekstegers, Taoufik Ouarrak, Ralf Zahn, Hüseyin Ince, Jochen Senges, Hugo A. Katus and Raffi Bekeredjian

MARC

LEADER 00000caa a2200000 c 4500
001 1572433981
003 DE-627
005 20220814124805.0
007 cr uuu---uuuuu
008 180427r20182017xx |||||o 00| ||eng c
024 7 |a 10.1002/ejhf.910  |2 doi 
035 |a (DE-627)1572433981 
035 |a (DE-576)502433981 
035 |a (DE-599)BSZ502433981 
035 |a (OCoLC)1341007847 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Geis, Nicolas  |d 1980-  |e VerfasserIn  |0 (DE-588)138513988  |0 (DE-627)696681854  |0 (DE-576)307885313  |4 aut 
245 1 0 |a Safety and efficacy of MitraClipTM therapy in patients with severely impaired left ventricular ejection fraction  |b results from the German transcatheter mitral valve interventions (TRAMI) registry  |c Nicolas A. Geis, Miriam Puls, Edith Lubos, Christine S. Zuern, Jennifer Franke, Robert Schueler, Ralph S. von Bardeleben, Peter Boekstegers, Taoufik Ouarrak, Ralf Zahn, Hüseyin Ince, Jochen Senges, Hugo A. Katus and Raffi Bekeredjian 
264 1 |c 2018 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Im Titel ist "TM" hochgestellt 
500 |a Online publish-ahead-of-print: 18 August 2017 
500 |a Gesehen am 27.04.2018 
520 |a Aims The aim of the present study was to assess the safety and efficacy of percutaneous mitral valve repair using the MitraClip™ device in patients with severely reduced systolic left ventricular (LV) function. Methods and results Among 777 MitraClip™ implantations included in the German mitral valve registry, we identified 256 patients suffering from severely reduced LV function [ejection fraction (EF) <30%] in whom successful percutaneous mitral valve repair was performed. Procedural safety, efficacy, and 1-year outcome was compared with 241 patients with preserved LV function (EF >50%) and 280 patients presenting with an EF 30-50% prior to MitraClip™ therapy. High procedural success rates, low periprocedural complication rates, and low residual mitral regurgitation grades at discharge were achieved throughout all groups. In-hospital mortality was low and comparable in all groups. After 1 year, mortality rates were 24.2% (EF <30%), 17.3% (EF 30-50%), and 18.9% (EF >50%). Major adverse cardiac or cardiovascular event rates were 29.7% (EF <30%), 24.4% (EF 30-50%), and 23.5% (EF >50%). Procedural failure was the main predictor for mortality in EF <30% patients (hazard ratio 10.38; 95% CI 3.71-29.02). Improved clinical symptoms were observed in the majority of patients in all groups. Thus, 69.5% of EF <30% patients improved by one or more New York Heart Association functional class. Compared with patients with preserved LV function, this is a significantly larger proportion (EF >50%: 56.8%; P < 0.05). Moreover, quality of life, being very poor at baseline, improved distinctively in severe heart failure patients. Conclusion In patients with severely reduced systolic LV function undergoing MitraClip™ therapy, procedural safety, efficacy, and clinical improvement after 1 year are comparable to patients with preserved LV function. 
534 |c 2017 
650 4 |a Outcome 
650 4 |a Heart failure 
650 4 |a MitraClip™ 
650 4 |a Mitral regurgitation 
650 4 |a Percutaneous mitral valve repair 
700 1 |a Katus, Hugo  |d 1951-  |e VerfasserIn  |0 (DE-588)108916618  |0 (DE-627)577155040  |0 (DE-576)289625076  |4 aut 
700 1 |a Bekeredjian, Raffi  |d 1972-  |e VerfasserIn  |0 (DE-588)122088271  |0 (DE-627)705767930  |0 (DE-576)293085781  |4 aut 
773 0 8 |i Enthalten in  |t European journal of heart failure  |d Oxford : Wiley, 1999  |g 20(2018), 3, Seite 598-608  |h Online-Ressource  |w (DE-627)306658291  |w (DE-600)1500332-2  |w (DE-576)081985983  |x 1879-0844  |7 nnas  |a Safety and efficacy of MitraClipTM therapy in patients with severely impaired left ventricular ejection fraction results from the German transcatheter mitral valve interventions (TRAMI) registry 
773 1 8 |g volume:20  |g year:2018  |g number:3  |g pages:598-608  |g extent:11  |a Safety and efficacy of MitraClipTM therapy in patients with severely impaired left ventricular ejection fraction results from the German transcatheter mitral valve interventions (TRAMI) registry 
856 4 0 |u http://dx.doi.org/10.1002/ejhf.910  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/ejhf.910  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180427 
993 |a Article 
994 |a 2018 
998 |g 122088271  |a Bekeredjian, Raffi  |m 122088271:Bekeredjian, Raffi  |d 910000  |d 910100  |e 910000PB122088271  |e 910100PB122088271  |k 0/910000/  |k 1/910000/910100/  |p 14  |y j 
998 |g 108916618  |a Katus, Hugo  |m 108916618:Katus, Hugo  |d 910000  |d 910100  |e 910000PK108916618  |e 910100PK108916618  |k 0/910000/  |k 1/910000/910100/  |p 13 
998 |g 138513988  |a Geis, Nicolas  |m 138513988:Geis, Nicolas  |d 910000  |d 910100  |e 910000PG138513988  |e 910100PG138513988  |k 0/910000/  |k 1/910000/910100/  |p 1  |x j 
999 |a KXP-PPN1572433981  |e 3007352096 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"2018"}],"note":["Im Titel ist \"TM\" hochgestellt","Online publish-ahead-of-print: 18 August 2017","Gesehen am 27.04.2018"],"title":[{"title":"Safety and efficacy of MitraClipTM therapy in patients with severely impaired left ventricular ejection fraction","title_sort":"Safety and efficacy of MitraClipTM therapy in patients with severely impaired left ventricular ejection fraction","subtitle":"results from the German transcatheter mitral valve interventions (TRAMI) registry"}],"id":{"eki":["1572433981"],"doi":["10.1002/ejhf.910"]},"name":{"displayForm":["Nicolas A. Geis, Miriam Puls, Edith Lubos, Christine S. Zuern, Jennifer Franke, Robert Schueler, Ralph S. von Bardeleben, Peter Boekstegers, Taoufik Ouarrak, Ralf Zahn, Hüseyin Ince, Jochen Senges, Hugo A. Katus and Raffi Bekeredjian"]},"physDesc":[{"extent":"11 S."}],"relHost":[{"titleAlt":[{"title":"EJHF"}],"part":{"year":"2018","pages":"598-608","issue":"3","text":"20(2018), 3, Seite 598-608","extent":"11","volume":"20"},"language":["eng"],"disp":"Safety and efficacy of MitraClipTM therapy in patients with severely impaired left ventricular ejection fraction results from the German transcatheter mitral valve interventions (TRAMI) registryEuropean journal of heart failure","type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"publisherPlace":"Oxford ; Amsterdam [u.a.] ; Oxford [u.a.] ; Oxford","dateIssuedDisp":"1999-","dateIssuedKey":"1999","publisher":"Oxford University Press ; Elsevier Science ; Oxford Univ. Press ; Wiley"}],"pubHistory":["1.1999 -"],"note":["Gesehen am 07.01.25"],"title":[{"title":"European journal of heart failure","subtitle":"journal of the Working Group on Heart Failure of the European Society of Cardiology","title_sort":"European journal of heart failure"}],"id":{"doi":["10.1002/(ISSN)1879-0844"],"issn":["1879-0844"],"zdb":["1500332-2"],"eki":["306658291"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"306658291"}],"recId":"1572433981","person":[{"family":"Geis","display":"Geis, Nicolas","role":"aut","given":"Nicolas"},{"given":"Hugo","role":"aut","family":"Katus","display":"Katus, Hugo"},{"display":"Bekeredjian, Raffi","family":"Bekeredjian","role":"aut","given":"Raffi"}],"language":["eng"]} 
SRT |a GEISNICOLASAFETYANDE2018