Ab interno gel implant for the treatment of glaucoma patients with or without prior glaucoma surgery: 1-year results

Purpose: The purpose of this study is to evaluate IOP lowering effects and complication management of an ab interno gel implant for the treatment of patients refractory to antiglaucoma medication or glaucoma surgery. Methods: Retrospective analysis of the medical records of 242 consecutive eyes of 1...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hengerer, Fritz (VerfasserIn) , Conrad-Hengerer, Ina (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2017
In: Journal of glaucoma
Year: 2017, Jahrgang: 26, Heft: 12, Pages: 1130-1136
ISSN:1536-481X
Online-Zugang:Verlag, Volltext: https://insights.ovid.com/pubmed?pmid=29035911
Volltext
Verfasserangaben:Fritz H. Hengerer, MD, PhD, Thomas Kohnen, MD, PhD, Michael Mueller, MD, Ina Conrad-Hengerer, MD, PhD

MARC

LEADER 00000caa a2200000 c 4500
001 1572647779
003 DE-627
005 20220814132131.0
007 cr uuu---uuuuu
008 180504s2017 xx |||||o 00| ||eng c
024 7 |a 10.1097/IJG.0000000000000803  |2 doi 
035 |a (DE-627)1572647779 
035 |a (DE-576)502647779 
035 |a (DE-599)BSZ502647779 
035 |a (OCoLC)1341008188 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hengerer, Fritz  |d 1970-  |e VerfasserIn  |0 (DE-588)12088142X  |0 (DE-627)705060470  |0 (DE-576)292429053  |4 aut 
245 1 0 |a Ab interno gel implant for the treatment of glaucoma patients with or without prior glaucoma surgery  |b 1-year results  |c Fritz H. Hengerer, MD, PhD, Thomas Kohnen, MD, PhD, Michael Mueller, MD, Ina Conrad-Hengerer, MD, PhD 
264 1 |c 2017 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a DOI funktioniert nicht 
500 |a Gesehen am 04.05.2018 
520 |a Purpose: The purpose of this study is to evaluate IOP lowering effects and complication management of an ab interno gel implant for the treatment of patients refractory to antiglaucoma medication or glaucoma surgery. Methods: Retrospective analysis of the medical records of 242 consecutive eyes of 146 patients with uncontrolled intraocular pressure (IOP) despite maximum tolerated medical therapy or prior surgical intervention that underwent XEN45 implantation (as sole procedure or in combination with cataract surgery) between March 2014 and June 2015. Data included IOP, number of glaucoma medications, the need for additional surgery, needling, and complications. Results: During the study period, mean IOP had decreased by 54.1% from 32.19 (±9.1) mm Hg to 14.24 (±4.0) mm Hg (P=0.00; Wilcoxon test). The number of antiglaucoma medications had decreased from a mean of 3.13±1.0 to 0.3±0.7 (P=0.00; Wilcoxon test). Needling was required between week 1 and months 3 in 27.7% of all eyes to enhance the outflow. Hypotony (IOP<6 mm Hg) was observed in 9 eyes (4.0%) at 1 month but normalized in all eyes at 12 months postoperatively. Two eyes experienced hypotony requiring the refill of the anterior chamber. Conclusions: Our data indicate that the XEN45 gel implant has a favorable safety profile and is an effective treatment option for controlling IOP in glaucoma patients with unregulated IOP despite IOP lowering medical therapy or prior surgical intervention. It offers an effective approach, both as sole procedure and in combination with cataract surgery. 
650 4 |a Aged 
650 4 |a Anterior Chamber 
650 4 |a Female 
650 4 |a Filtering Surgery 
650 4 |a Follow-Up Studies 
650 4 |a Gels 
650 4 |a Glaucoma 
650 4 |a Glaucoma Drainage Implants 
650 4 |a Humans 
650 4 |a Intraocular Pressure 
650 4 |a Male 
650 4 |a Middle Aged 
650 4 |a Prosthesis Design 
650 4 |a Reoperation 
650 4 |a Retrospective Studies 
650 4 |a Time Factors 
650 4 |a Tonometry, Ocular 
650 4 |a Trabeculectomy 
650 4 |a Treatment Outcome 
700 1 |a Conrad-Hengerer, Ina  |d 1973-  |e VerfasserIn  |0 (DE-588)1020458305  |0 (DE-627)691225273  |0 (DE-576)36048686X  |4 aut 
773 0 8 |i Enthalten in  |t Journal of glaucoma  |d Philadelphia, Pa. : Lippincott Williams & Wilkins, 1992  |g 26(2017), 12, Seite 1130-1136  |h Online-Ressource  |w (DE-627)336152957  |w (DE-600)2060541-9  |w (DE-576)103868410  |x 1536-481X  |7 nnas  |a Ab interno gel implant for the treatment of glaucoma patients with or without prior glaucoma surgery 1-year results 
773 1 8 |g volume:26  |g year:2017  |g number:12  |g pages:1130-1136  |g extent:7  |a Ab interno gel implant for the treatment of glaucoma patients with or without prior glaucoma surgery 1-year results 
856 4 0 |u https://insights.ovid.com/pubmed?pmid=29035911  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180504 
993 |a Article 
994 |a 2017 
998 |g 1020458305  |a Conrad-Hengerer, Ina  |m 1020458305:Conrad-Hengerer, Ina  |d 910000  |d 910900  |e 910000PC1020458305  |e 910900PC1020458305  |k 0/910000/  |k 1/910000/910900/  |p 4  |y j 
998 |g 12088142X  |a Hengerer, Fritz  |m 12088142X:Hengerer, Fritz  |d 910000  |d 910900  |e 910000PH12088142X  |e 910900PH12088142X  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1572647779  |e 3007943116 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["DOI funktioniert nicht","Gesehen am 04.05.2018"],"language":["eng"],"recId":"1572647779","person":[{"roleDisplay":"VerfasserIn","display":"Hengerer, Fritz","role":"aut","family":"Hengerer","given":"Fritz"},{"display":"Conrad-Hengerer, Ina","roleDisplay":"VerfasserIn","role":"aut","family":"Conrad-Hengerer","given":"Ina"}],"title":[{"title":"Ab interno gel implant for the treatment of glaucoma patients with or without prior glaucoma surgery","subtitle":"1-year results","title_sort":"Ab interno gel implant for the treatment of glaucoma patients with or without prior glaucoma surgery"}],"physDesc":[{"extent":"7 S."}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2060541-9"],"eki":["336152957"],"issn":["1536-481X"]},"origin":[{"publisherPlace":"Philadelphia, Pa.","dateIssuedKey":"1992","publisher":"Lippincott Williams & Wilkins","dateIssuedDisp":"1992-"}],"recId":"336152957","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Ab interno gel implant for the treatment of glaucoma patients with or without prior glaucoma surgery 1-year resultsJournal of glaucoma","note":["Gesehen am 28.05.19"],"part":{"year":"2017","pages":"1130-1136","issue":"12","volume":"26","text":"26(2017), 12, Seite 1130-1136","extent":"7"},"titleAlt":[{"title":"Glaucoma"}],"pubHistory":["1.1992 -"],"title":[{"title_sort":"Journal of glaucoma","title":"Journal of glaucoma"}]}],"name":{"displayForm":["Fritz H. Hengerer, MD, PhD, Thomas Kohnen, MD, PhD, Michael Mueller, MD, Ina Conrad-Hengerer, MD, PhD"]},"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"2017"}],"id":{"eki":["1572647779"],"doi":["10.1097/IJG.0000000000000803"]}} 
SRT |a HENGERERFRABINTERNOG2017