The 10B based jalousie neutron detector: an alternative for 3He filled position sensitive counter tubes

Over the last decades 3He filled proportional counter tubes were the working horse employed to serve as neutron counters especially in cases where large area coverage was required. Today the lack of 3He demands the development of an alternative technology. Here we present a prototype neutron detecto...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Henske, Markus (VerfasserIn) , Klein, Martin (VerfasserIn) , Köhli, Markus (VerfasserIn) , Lennert, Peter (VerfasserIn) , Modzel, Gerd (VerfasserIn) , Schmidt, Ulrich (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2 June 2012
In: Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2012, Jahrgang: 686, Pages: 151-155
ISSN:1872-9576
DOI:10.1016/j.nima.2012.05.075
Online-Zugang:Verlag, kostenfrei registrierungspflichtig, Volltext: http://dx.doi.org/10.1016/j.nima.2012.05.075
Verlag, kostenfrei registrierungspflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S016890021200589X
Volltext
Verfasserangaben:M. Henske, M. Klein, M. Köhli, P. Lennert, G. Modzel, C.J. Schmidt, U. Schmidt

MARC

LEADER 00000caa a2200000 c 4500
001 1574254383
003 DE-627
005 20220814133917.0
007 cr uuu---uuuuu
008 180508s2012 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.nima.2012.05.075  |2 doi 
035 |a (DE-627)1574254383 
035 |a (DE-576)504254383 
035 |a (DE-599)BSZ504254383 
035 |a (OCoLC)1341009358 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Henske, Markus  |e VerfasserIn  |0 (DE-588)1159592802  |0 (DE-627)1022269607  |0 (DE-576)505057735  |4 aut 
245 1 4 |a The 10B based jalousie neutron detector  |b an alternative for 3He filled position sensitive counter tubes  |c M. Henske, M. Klein, M. Köhli, P. Lennert, G. Modzel, C.J. Schmidt, U. Schmidt 
246 3 3 |a The 10 B based jalousie neutron detector 
264 1 |c 2 June 2012 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.05.2018 
500 |a Im Titel sind "10" und "3" hochgestellt 
520 |a Over the last decades 3He filled proportional counter tubes were the working horse employed to serve as neutron counters especially in cases where large area coverage was required. Today the lack of 3He demands the development of an alternative technology. Here we present a prototype neutron detector that is based on a concept with solid 10B as neutron converter and aims for large area neutron detection applications. We report on first experimental results obtained with this prototype to demonstrate the feasibility and operational readiness of our concept. 
650 4 |a ASIC 
650 4 |a B 
650 4 |a FPGA 
650 4 |a He alternative 
650 4 |a Integrated readout 
650 4 |a Large area 
650 4 |a Neutron detector 
650 4 |a Position sensitive 
700 1 |a Klein, Martin  |e VerfasserIn  |0 (DE-588)124383572  |0 (DE-627)706620313  |0 (DE-576)294147683  |4 aut 
700 1 |a Köhli, Markus  |d 1984-  |e VerfasserIn  |0 (DE-588)1155859200  |0 (DE-627)1018340483  |0 (DE-576)501908013  |4 aut 
700 1 |a Lennert, Peter  |d 1949-  |e VerfasserIn  |0 (DE-588)1124747001  |0 (DE-627)878946063  |0 (DE-576)483117587  |4 aut 
700 1 |a Modzel, Gerd  |e VerfasserIn  |0 (DE-588)1054560056  |0 (DE-627)791603997  |0 (DE-576)267695012  |4 aut 
700 1 |a Schmidt, Ulrich  |e VerfasserIn  |0 (DE-588)140588892  |0 (DE-627)619816945  |0 (DE-576)318996782  |4 aut 
773 0 8 |i Enthalten in  |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment  |d [Amsterdam] : Elsevier, 1984  |g 686(2012), Seite 151-155  |h Online-Ressource  |w (DE-627)266014666  |w (DE-600)1466532-3  |w (DE-576)074959743  |x 1872-9576  |7 nnas  |a The 10B based jalousie neutron detector an alternative for 3He filled position sensitive counter tubes 
773 1 8 |g volume:686  |g year:2012  |g pages:151-155  |g extent:5  |a The 10B based jalousie neutron detector an alternative for 3He filled position sensitive counter tubes 
856 4 0 |u http://dx.doi.org/10.1016/j.nima.2012.05.075  |x Verlag  |z kostenfrei registrierungspflichtig  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S016890021200589X  |x Verlag  |z kostenfrei registrierungspflichtig  |3 Volltext 
951 |a AR 
992 |a 20180508 
993 |a Article 
994 |a 2012 
998 |g 1159592802  |a Henske, Markus  |m 1159592802:Henske, Markus  |p 1  |x j 
998 |g 140588892  |a Schmidt, Ulrich  |m 140588892:Schmidt, Ulrich  |d 130000  |d 130200  |e 130000PS140588892  |e 130200PS140588892  |k 0/130000/  |k 1/130000/130200/  |p 7  |y j 
998 |g 1054560056  |a Modzel, Gerd  |m 1054560056:Modzel, Gerd  |d 130000  |d 130200  |e 130000PM1054560056  |e 130200PM1054560056  |k 0/130000/  |k 1/130000/130200/  |p 5 
998 |g 1124747001  |a Lennert, Peter  |m 1124747001:Lennert, Peter  |d 130000  |d 130200  |e 130000PL1124747001  |e 130200PL1124747001  |k 0/130000/  |k 1/130000/130200/  |p 4 
998 |g 1155859200  |a Köhli, Markus  |m 1155859200:Köhli, Markus  |d 130000  |d 130200  |e 130000PK1155859200  |e 130200PK1155859200  |k 0/130000/  |k 1/130000/130200/  |p 3 
998 |g 124383572  |a Klein, Martin  |m 124383572:Klein, Martin  |d 130000  |d 130200  |e 130000PK124383572  |e 130200PK124383572  |k 0/130000/  |k 1/130000/130200/  |p 2 
999 |a KXP-PPN1574254383  |e 3008507107 
BIB |a Y 
SER |a journal 
JSO |a {"titleAlt":[{"title":"The 10 B based jalousie neutron detector"}],"language":["eng"],"person":[{"given":"Markus","role":"aut","display":"Henske, Markus","family":"Henske"},{"display":"Klein, Martin","family":"Klein","role":"aut","given":"Martin"},{"display":"Köhli, Markus","family":"Köhli","given":"Markus","role":"aut"},{"family":"Lennert","display":"Lennert, Peter","given":"Peter","role":"aut"},{"display":"Modzel, Gerd","family":"Modzel","given":"Gerd","role":"aut"},{"given":"Ulrich","role":"aut","family":"Schmidt","display":"Schmidt, Ulrich"}],"id":{"eki":["1574254383"],"doi":["10.1016/j.nima.2012.05.075"]},"physDesc":[{"extent":"5 S."}],"name":{"displayForm":["M. Henske, M. Klein, M. Köhli, P. Lennert, G. Modzel, C.J. Schmidt, U. Schmidt"]},"relHost":[{"part":{"pages":"151-155","year":"2012","volume":"686","text":"686(2012), Seite 151-155","extent":"5"},"titleAlt":[{"title":"Nuclear instruments & methods in physics research / A"}],"language":["eng"],"id":{"zdb":["1466532-3"],"issn":["1872-9576"],"eki":["266014666"]},"recId":"266014666","physDesc":[{"extent":"Online-Ressource"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"disp":"The 10B based jalousie neutron detector an alternative for 3He filled position sensitive counter tubesNuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment","title":[{"title":"Nuclear instruments & methods in physics research","title_sort":"Nuclear instruments & methods in physics research","subtitle":"a journal on accelerators, instrumentation and techniques applied to research in nuclear and atomic physics, materials science and related fields in physics","partname":"Accelerators, spectrometers, detectors and associated equipment"}],"note":["Gesehen am 24.05.23"],"pubHistory":["Nachgewiesen 226.1984 -"],"origin":[{"publisherPlace":"[Amsterdam] ; Amsterdam","dateIssuedKey":"1994","publisher":"Elsevier ; North-Holland Publ. Co.","dateIssuedDisp":"1994-"}]}],"recId":"1574254383","type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"10B based jalousie neutron detector","subtitle":"an alternative for 3He filled position sensitive counter tubes","title":"The 10B based jalousie neutron detector"}],"note":["Gesehen am 08.05.2018","Im Titel sind \"10\" und \"3\" hochgestellt"],"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2 June 2012"}]} 
SRT |a HENSKEMARK10BBASEDJA2201