Present state and issues in IORT Physics

Literature was reviewed to assess the physical aspects governing the present and emerging technologies used in intraoperative radiation therapy (IORT). Three major technologies were identified: treatment with electrons, treatment with external generators of kV X-rays and electronic brachytherapy. Al...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Hensley, Frank W. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 27 January 2017
In: Radiation oncology
Year: 2017, Jahrgang: 12
ISSN:1748-717X
DOI:10.1186/s13014-016-0754-z
Online-Zugang:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1186/s13014-016-0754-z
Verlag, kostenfrei, Volltext: https://doi.org/10.1186/s13014-016-0754-z
Volltext
Verfasserangaben:Frank W. Hensley

MARC

LEADER 00000caa a2200000 c 4500
001 1574255274
003 DE-627
005 20220814133934.0
007 cr uuu---uuuuu
008 180508s2017 xx |||||o 00| ||eng c
024 7 |a 10.1186/s13014-016-0754-z  |2 doi 
035 |a (DE-627)1574255274 
035 |a (DE-576)504255274 
035 |a (DE-599)BSZ504255274 
035 |a (OCoLC)1341009312 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Hensley, Frank W.  |e VerfasserIn  |0 (DE-588)1075059895  |0 (DE-627)832910562  |0 (DE-576)278454070  |4 aut 
245 1 0 |a Present state and issues in IORT Physics  |c Frank W. Hensley 
264 1 |c 27 January 2017 
300 |a 30 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 08.05.2018 
520 |a Literature was reviewed to assess the physical aspects governing the present and emerging technologies used in intraoperative radiation therapy (IORT). Three major technologies were identified: treatment with electrons, treatment with external generators of kV X-rays and electronic brachytherapy. Although also used in IORT, literature on brachytherapy with radioactive sources is not systematically reviewed since an extensive own body of specialized literature and reviews exists in this field. A comparison with radioactive sources is made in the use of balloon catheters for partial breast irradiation where these are applied in almost an identical applicator technique as used with kV X-ray sources. The physical constraints of adaption of the dose distribution to the extended target in breast IORT are compared. Concerning further physical issues, the literature on radiation protection, commissioning, calibration, quality assurance (QA) and in-vivo dosimetry of the three technologies was reviewed. Several issues were found in the calibration and the use of dosimetry detectors and phantoms for low energy X-rays which require further investigation. The uncertainties in the different steps of dose determination were estimated, leading to an estimated total uncertainty of around 10-15% for IORT procedures. The dose inhomogeneity caused by the prescription of electrons at 90% and by the steep dose gradient of kV X-rays causes additional deviations from prescription dose which must be considered in the assessment of dose response in IORT. 
650 4 |a Dose Distribution 
650 4 |a Ionization Chamber 
650 4 |a Pulse Dose 
650 4 |a Radiochromic Film 
650 4 |a Skin Dose 
773 0 8 |i Enthalten in  |t Radiation oncology  |d London : BioMed Central, 2006  |g 12(2017) Artikel-Nummer 37, 30 Seiten  |h Online-Ressource  |w (DE-627)508725739  |w (DE-600)2224965-5  |w (DE-576)260614815  |x 1748-717X  |7 nnas  |a Present state and issues in IORT Physics 
773 1 8 |g volume:12  |g year:2017  |g extent:30  |a Present state and issues in IORT Physics 
856 4 0 |u http://dx.doi.org/10.1186/s13014-016-0754-z  |x Verlag  |z kostenfrei  |3 Volltext 
856 4 0 |u https://doi.org/10.1186/s13014-016-0754-z  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20180508 
993 |a Article 
994 |a 2017 
998 |g 1075059895  |a Hensley, Frank W.  |m 1075059895:Hensley, Frank W.  |d 910000  |d 911400  |e 910000PH1075059895  |e 911400PH1075059895  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j  |y j 
999 |a KXP-PPN1574255274  |e 3008508618 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1574255274"],"doi":["10.1186/s13014-016-0754-z"]},"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"27 January 2017"}],"name":{"displayForm":["Frank W. Hensley"]},"relHost":[{"id":{"eki":["508725739"],"zdb":["2224965-5"],"issn":["1748-717X"]},"origin":[{"publisherPlace":"London","dateIssuedKey":"2006","publisher":"BioMed Central","dateIssuedDisp":"2006-"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Radiation oncology","title_sort":"Radiation oncology"}],"recId":"508725739","language":["eng"],"disp":"Present state and issues in IORT PhysicsRadiation oncology","note":["Gesehen am 06.09.10"],"type":{"bibl":"periodical","media":"Online-Ressource"},"part":{"extent":"30","text":"12(2017) Artikel-Nummer 37, 30 Seiten","volume":"12","year":"2017"},"pubHistory":["1.2006 -"]}],"physDesc":[{"extent":"30 S."}],"title":[{"title":"Present state and issues in IORT Physics","title_sort":"Present state and issues in IORT Physics"}],"person":[{"role":"aut","display":"Hensley, Frank W.","roleDisplay":"VerfasserIn","given":"Frank W.","family":"Hensley"}],"recId":"1574255274","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 08.05.2018"]} 
SRT |a HENSLEYFRAPRESENTSTA2720