Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size: the MIPH Eye&Health Study

Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-secti...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schuster, Alexander K. (VerfasserIn) , Fischer, Joachim E. (VerfasserIn) , Voßmerbäumer, Urs (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2017
In: Acta ophthalmologica
Year: 2017, Jahrgang: 95, Heft: 2, Pages: 175-181
ISSN:1755-3768
DOI:10.1111/aos.13184
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1111/aos.13184
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/aos.13184
Volltext
Verfasserangaben:Alexander K. Schuster, Joachim E. Fischer, and Urs Vossmerbaeumer

MARC

LEADER 00000caa a2200000 c 4500
001 1574268937
003 DE-627
005 20241209143352.0
007 cr uuu---uuuuu
008 180508s2017 xx |||||o 00| ||eng c
024 7 |a 10.1111/aos.13184  |2 doi 
035 |a (DE-627)1574268937 
035 |a (DE-576)504268937 
035 |a (DE-599)BSZ504268937 
035 |a (OCoLC)1341009299 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schuster, Alexander K.  |d 1985-  |e VerfasserIn  |0 (DE-588)1049518810  |0 (DE-627)782185789  |0 (DE-576)403510139  |4 aut 
245 1 0 |a Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size  |b the MIPH Eye&Health Study  |c Alexander K. Schuster, Joachim E. Fischer, and Urs Vossmerbaeumer 
264 1 |c 2017 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 4. August 2016 
500 |a Gesehen am 08.05.2018 
520 |a Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of <−4 or >+3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 subjects served as emmetropic group (−0.5 ≤ x ≤+0.5 dioptres). Previous ocular surgery was exclusion criterion. Results Six hundred and sixty-eight eyes of 398 persons [292 male (76%); age range; 18-66 years] were included in the study. In the myopic group, 105 eyes had a concave iris configuration (26%), while in the hyperopic group, no eye had this configuration (0%) and in the emmetropic group five eyes (5%). Convex iris configuration was found in 96% of hyperopic, in 85% of the emmetropic and in 67% of the myopic eyes. There was an association between concave iris configuration and myopia, younger age and male gender, and with anterior chamber angle width. Conclusion Spectral domain OCT images can be used for analysis of the iris structure and geometry. Our results are limited to the properties of the study population having an age range from 18 to 66 years and consisting mainly of men. 
650 4 |a age 
650 4 |a iris 
650 4 |a optical coherence tomography 
650 4 |a pupil size 
650 4 |a refraction 
700 1 |a Fischer, Joachim E.  |d 1957-  |e VerfasserIn  |0 (DE-588)1029135800  |0 (DE-627)732480620  |0 (DE-576)37658775X  |4 aut 
700 1 |a Voßmerbäumer, Urs  |d 1973-  |e VerfasserIn  |0 (DE-588)121535819  |0 (DE-627)705518868  |0 (DE-576)292759541  |4 aut 
773 0 8 |i Enthalten in  |t Acta ophthalmologica  |d Oxford : Blackwell, 2008  |g 95(2017), 2, Seite 175-181  |h Online-Ressource  |w (DE-627)585797218  |w (DE-600)2466981-7  |w (DE-576)290238277  |x 1755-3768  |7 nnas  |a Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size the MIPH Eye&Health Study 
773 1 8 |g volume:95  |g year:2017  |g number:2  |g pages:175-181  |g extent:7  |a Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size the MIPH Eye&Health Study 
856 4 0 |u http://dx.doi.org/10.1111/aos.13184  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1111/aos.13184  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180508 
993 |a Article 
994 |a 2017 
998 |g 121535819  |a Voßmerbäumer, Urs  |m 121535819:Voßmerbäumer, Urs  |d 60000  |d 65300  |e 60000PV121535819  |e 65300PV121535819  |k 0/60000/  |k 1/60000/65300/  |p 3  |y j 
998 |g 1029135800  |a Fischer, Joachim E.  |m 1029135800:Fischer, Joachim E.  |d 60000  |d 65300  |e 60000PF1029135800  |e 65300PF1029135800  |k 0/60000/  |k 1/60000/65300/  |p 2 
998 |g 1049518810  |a Schuster, Alexander K.  |m 1049518810:Schuster, Alexander K.  |p 1  |x j 
999 |a KXP-PPN1574268937  |e 3008530168 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"given":"Alexander K.","role":"aut","family":"Schuster","display":"Schuster, Alexander K."},{"given":"Joachim E.","role":"aut","display":"Fischer, Joachim E.","family":"Fischer"},{"display":"Voßmerbäumer, Urs","family":"Voßmerbäumer","role":"aut","given":"Urs"}],"language":["eng"],"title":[{"title":"Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size","subtitle":"the MIPH Eye&Health Study","title_sort":"Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size"}],"note":["Online veröffentlicht: 4. August 2016","Gesehen am 08.05.2018"],"origin":[{"dateIssuedDisp":"2017","dateIssuedKey":"2017"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"7 S."}],"name":{"displayForm":["Alexander K. Schuster, Joachim E. Fischer, and Urs Vossmerbaeumer"]},"relHost":[{"part":{"pages":"175-181","year":"2017","text":"95(2017), 2, Seite 175-181","issue":"2","extent":"7","volume":"95"},"language":["eng"],"corporate":[{"display":"European Association for Vision and Eye Research","role":"isb"}],"id":{"issn":["1755-3768"],"zdb":["2466981-7"],"doi":["10.1111/(ISSN)1755-3768"],"eki":["585797218"]},"name":{"displayForm":["European Association for Vision and Eye Research"]},"physDesc":[{"extent":"Online-Ressource"}],"recId":"585797218","type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size the MIPH Eye&Health StudyActa ophthalmologica","origin":[{"publisherPlace":"Oxford","publisher":"Blackwell","dateIssuedKey":"2008","dateIssuedDisp":"2008-"}],"pubHistory":["86.2008 -"],"note":["Gesehen am 25.03.22"],"title":[{"title_sort":"Acta ophthalmologica","subtitle":"the official journal of the Nordic Ophthalmological Societies","title":"Acta ophthalmologica"}]}],"recId":"1574268937","id":{"doi":["10.1111/aos.13184"],"eki":["1574268937"]}} 
SRT |a SCHUSTERALCURVATUREO2017