Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks
Carbon ion beam radiotherapy enables a very localised dose deposition. However, even small changes in the patient geometry or positioning errors can significantly distort the dose distribution. A live, non-invasive monitoring system of the beam delivery within the patient is therefore highly desirab...
Gespeichert in:
| Hauptverfasser: | , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
22 May 2017
|
| In: |
Physics in medicine and biology
Year: 2017, Jahrgang: 62, Heft: 12 |
| ISSN: | 1361-6560 |
| DOI: | 10.1088/1361-6560/aa6aeb |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1088/1361-6560/aa6aeb Verlag, Volltext: http://stacks.iop.org/0031-9155/62/i=12/a=4884 |
| Verfasserangaben: | Anna Merle Reinhart, Claudia Katharina Spindeldreier, Jan Jakubek and Mária Martišíková |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1574300156 | ||
| 003 | DE-627 | ||
| 005 | 20230427042855.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180509s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1088/1361-6560/aa6aeb |2 doi | |
| 035 | |a (DE-627)1574300156 | ||
| 035 | |a (DE-576)504300156 | ||
| 035 | |a (DE-599)BSZ504300156 | ||
| 035 | |a (OCoLC)1341009449 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Reinhart, Anna Merle |e VerfasserIn |0 (DE-588)115867547X |0 (DE-627)1020747773 |0 (DE-576)504299824 |4 aut | |
| 245 | 1 | 0 | |a Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks |c Anna Merle Reinhart, Claudia Katharina Spindeldreier, Jan Jakubek and Mária Martišíková |
| 264 | 1 | |c 22 May 2017 | |
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 09.05.2018 | ||
| 520 | |a Carbon ion beam radiotherapy enables a very localised dose deposition. However, even small changes in the patient geometry or positioning errors can significantly distort the dose distribution. A live, non-invasive monitoring system of the beam delivery within the patient is therefore highly desirable, and could improve patient treatment. We present a novel three-dimensional method for imaging the beam in the irradiated object, exploiting the measured tracks of single secondary ions emerging under irradiation. The secondary particle tracks are detected with a TimePix stack—a set of parallel pixelated semiconductor detectors. We developed a three-dimensional reconstruction algorithm based on maximum likelihood expectation maximization. We demonstrate the applicability of the new method in the irradiation of a cylindrical PMMA phantom of human head size with a carbon ion pencil beam of ##IMG## [http://ej.iop.org/images/0031-9155/62/12/4884/pmbaa6aebieqn001.gif] $226$ MeV u −1 . The beam image in the phantom is reconstructed from a set of nine discrete detector positions between ##IMG## [http://ej.iop.org/images/0031-9155/62/12/4884/pmbaa6aebieqn002.gif] $-80^\circ$ and ##IMG## [http://ej.iop.org/images/0031-9155/62/12/4884/pmbaa6aebieqn003.gif] $50^\circ$ from the beam axis. Furthermore, we demonstrate the potential to visualize inhomogeneities by irradiating a PMMA phantom with an air gap as well as bone and adipose tissue surrogate inserts. We successfully reconstructed a three-dimensional image of the treatment beam in the phantom from single secondary ion tracks. The beam image corresponds well to the beam direction and energy. In addition, cylindrical inhomogeneities with a diameter of ##IMG## [http://ej.iop.org/images/0031-9155/62/12/4884/pmbaa6aebieqn004.gif] $2.85$ cm and density differences down to ##IMG## [http://ej.iop.org/images/0031-9155/62/12/4884/pmbaa6aebieqn005.gif] $0.3$ g cm −3 to the surrounding material are clearly visualized. This novel three-dimensional method to image a therapeutic carbon ion beam in the irradiated object does not interfere with the treatment and requires knowledge only of single secondary ion tracks. Even with detectors with only a small angular coverage, the three-dimensional reconstruction of the fragmentation points presented in this work was found to be feasible. | ||
| 700 | 1 | |a Renkamp, Claudia Katharina |d 1990- |e VerfasserIn |0 (DE-588)1153576384 |0 (DE-627)101508625X |0 (DE-576)500325286 |4 aut | |
| 700 | 1 | |a Martišíková, Mária |d 1979- |e VerfasserIn |0 (DE-588)1076839649 |0 (DE-627)835386767 |0 (DE-576)252899369 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Physics in medicine and biology |d Bristol : IOP Publ., 1956 |g 62(2017,12) Artikel-Nummer 4884, 14 Seiten |h Online-Ressource |w (DE-627)269016163 |w (DE-600)1473501-5 |w (DE-576)088704130 |x 1361-6560 |7 nnas |a Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks |
| 773 | 1 | 8 | |g volume:62 |g year:2017 |g number:12 |a Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1088/1361-6560/aa6aeb |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://stacks.iop.org/0031-9155/62/i=12/a=4884 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180509 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 1076839649 |a Martišíková, Mária |m 1076839649:Martišíková, Mária |d 50000 |e 50000PM1076839649 |k 0/50000/ |p 4 |y j | ||
| 998 | |g 1153576384 |a Renkamp, Claudia Katharina |m 1153576384:Renkamp, Claudia Katharina |d 910000 |d 950000 |d 950400 |e 910000PR1153576384 |e 950000PR1153576384 |e 950400PR1153576384 |k 0/910000/ |k 1/910000/950000/ |k 2/910000/950000/950400/ |p 2 | ||
| 998 | |g 115867547X |a Reinhart, Anna Merle |m 115867547X:Reinhart, Anna Merle |d 910000 |d 950000 |d 950400 |e 910000PR115867547X |e 950000PR115867547X |e 950400PR115867547X |k 0/910000/ |k 1/910000/950000/ |k 2/910000/950000/950400/ |p 1 |x j | ||
| 999 | |a KXP-PPN1574300156 |e 3008872921 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"note":["Gesehen am 09.05.2018"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"title":[{"title":"Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks","title_sort":"Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks"}],"person":[{"role":"aut","given":"Anna Merle","family":"Reinhart","display":"Reinhart, Anna Merle"},{"family":"Renkamp","given":"Claudia Katharina","role":"aut","display":"Renkamp, Claudia Katharina"},{"display":"Martišíková, Mária","family":"Martišíková","role":"aut","given":"Mária"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"pubHistory":["1.1956 -"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"title":[{"title_sort":"Physics in medicine and biology","title":"Physics in medicine and biology","subtitle":"an official journal of the Institute of Physics and Engineering in Medicine"}],"disp":"Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracksPhysics in medicine and biology","recId":"269016163","part":{"year":"2017","issue":"12","volume":"62","text":"62(2017,12) Artikel-Nummer 4884, 14 Seiten"},"id":{"zdb":["1473501-5"],"issn":["1361-6560"],"eki":["269016163"]},"origin":[{"publisherPlace":"Bristol","dateIssuedKey":"1956","publisher":"IOP Publ.","dateIssuedDisp":"1956-"}]}],"recId":"1574300156","name":{"displayForm":["Anna Merle Reinhart, Claudia Katharina Spindeldreier, Jan Jakubek and Mária Martišíková"]},"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"22 May 2017"}],"id":{"doi":["10.1088/1361-6560/aa6aeb"],"eki":["1574300156"]}} | ||
| SRT | |a REINHARTANTHREEDIMEN2220 | ||