Carbon and oxygen minibeam radiation therapy: An experimental dosimetric evaluation

Purpose To perform dosimetric characterization of a minibeam collimator in both carbon and oxygen ion beams to guide optimal setup geometry and irradiation for future radiobiological studies. Methods Carbon and oxygen minibeams were generated using a prototype tungsten multislit collimator presentin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Immaculada, Martínez‐Rovira (VerfasserIn) , Brons, Stephan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 29 May 2017
In: Medical physics
Year: 2017, Jahrgang: 44, Heft: 8, Pages: 4223-4229
ISSN:2473-4209
DOI:10.1002/mp.12383
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1002/mp.12383
Verlag, Volltext: https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/mp.12383
Volltext
Verfasserangaben:Martínez‐Rovira Immaculada, González Wilfredo, Brons Stephan, Prezado Yolanda

MARC

LEADER 00000caa a2200000 c 4500
001 1574338838
003 DE-627
005 20240316100350.0
007 cr uuu---uuuuu
008 180509s2017 xx |||||o 00| ||eng c
024 7 |a 10.1002/mp.12383  |2 doi 
035 |a (DE-627)1574338838 
035 |a (DE-576)504338838 
035 |a (DE-599)BSZ504338838 
035 |a (OCoLC)1341009364 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Immaculada, Martínez‐Rovira  |e VerfasserIn  |4 aut 
245 1 0 |a Carbon and oxygen minibeam radiation therapy  |b An experimental dosimetric evaluation  |c Martínez‐Rovira Immaculada, González Wilfredo, Brons Stephan, Prezado Yolanda 
264 1 |c 29 May 2017 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.05.2018 
520 |a Purpose To perform dosimetric characterization of a minibeam collimator in both carbon and oxygen ion beams to guide optimal setup geometry and irradiation for future radiobiological studies. Methods Carbon and oxygen minibeams were generated using a prototype tungsten multislit collimator presenting line apertures 700 ?m wide, which are spaced 3500 ?m centre?to?centre distance apart. Several radiation beam spots generated the desired field size of 15 ? 15 mm2 and production of a 50 mm long spread out Bragg peak (SOBP) centered at 80 mm depth in water. Dose evaluations were performed with two different detectors: a PTW microDiamond single crystal diamond detector and radiochromic films (EBT3). Peak?to?valley dose ratio (PVDR) values, output factors (OF), penumbras, and full width at half maximum (FWHM) were measured. Results Measured lateral dose profiles exhibited spatial fractionation of dose at depth in a water phantom in the expected form of peaks and valleys for both carbon and oxygen radiation fields. The diamond detector and radiochromic film provided measurements of PVDR in good agreement. PVDR values at shallow depth were about 60 and decreased to about 10 at 80 mm depth in water. OF in the center of the SOBP was about 0.4; this value is larger than the corresponding one in proton minibeam radiation therapy measured using a comparable collimator due to a reduced lateral scattering for carbon and oxygen minibeams. Conclusions Carbon and oxygen minibeams may be produced by a mechanical collimator. PVDR values and output factors measured in this first study of these minibeam radiation types indicate there is potential for their therapeutic use. Optimization of minibeam collimator design and the number and size of focal spots for irradiation are advocated to improve PDVR values and dose distributions for each specific applied use. 
650 4 |a carbon and oxygen beams 
650 4 |a hadron therapy 
650 4 |a minibeam radiation therapy (MBRT) 
700 1 |a Brons, Stephan  |e VerfasserIn  |0 (DE-588)1072782375  |0 (DE-627)828233594  |0 (DE-576)434240478  |4 aut 
773 0 8 |i Enthalten in  |t Medical physics  |d Hoboken, NJ : Wiley, 1974  |g 44(2017), 8, Seite 4223-4229  |h Online-Ressource  |w (DE-627)265784867  |w (DE-600)1466421-5  |w (DE-576)074891243  |x 2473-4209  |7 nnas  |a Carbon and oxygen minibeam radiation therapy An experimental dosimetric evaluation 
773 1 8 |g volume:44  |g year:2017  |g number:8  |g pages:4223-4229  |g extent:7  |a Carbon and oxygen minibeam radiation therapy An experimental dosimetric evaluation 
856 4 0 |u http://dx.doi.org/10.1002/mp.12383  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://aapm.onlinelibrary.wiley.com/doi/abs/10.1002/mp.12383  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180509 
993 |a Article 
994 |a 2017 
998 |g 1072782375  |a Brons, Stephan  |m 1072782375:Brons, Stephan  |d 910000  |d 950000  |d 950400  |e 910000PB1072782375  |e 950000PB1072782375  |e 950400PB1072782375  |k 0/910000/  |k 1/910000/950000/  |k 2/910000/950000/950400/  |p 3 
999 |a KXP-PPN1574338838  |e 3009109326 
BIB |a Y 
SER |a journal 
JSO |a {"recId":"1574338838","id":{"doi":["10.1002/mp.12383"],"eki":["1574338838"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedDisp":"29 May 2017","dateIssuedKey":"2017"}],"name":{"displayForm":["Martínez‐Rovira Immaculada, González Wilfredo, Brons Stephan, Prezado Yolanda"]},"note":["Gesehen am 09.05.2018"],"language":["eng"],"person":[{"given":"Martínez‐Rovira","role":"aut","family":"Immaculada","display":"Immaculada, Martínez‐Rovira"},{"given":"Stephan","display":"Brons, Stephan","role":"aut","family":"Brons"}],"relHost":[{"language":["eng"],"name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]},"recId":"265784867","type":{"media":"Online-Ressource","bibl":"periodical"},"physDesc":[{"extent":"Online-Ressource"}],"part":{"volume":"44","text":"44(2017), 8, Seite 4223-4229","extent":"7","issue":"8","year":"2017","pages":"4223-4229"},"titleAlt":[{"title":"Medical physics online"}],"note":["Gesehen am 01.08.2025"],"pubHistory":["1.1974 -"],"disp":"Carbon and oxygen minibeam radiation therapy An experimental dosimetric evaluationMedical physics","origin":[{"dateIssuedDisp":"1974-","dateIssuedKey":"1974","publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY","publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]"}],"id":{"eki":["265784867"],"zdb":["1466421-5"],"issn":["2473-4209","1522-8541"]},"title":[{"title":"Medical physics","title_sort":"Medical physics"}]}],"physDesc":[{"extent":"7 S."}],"title":[{"title":"Carbon and oxygen minibeam radiation therapy","title_sort":"Carbon and oxygen minibeam radiation therapy","subtitle":"An experimental dosimetric evaluation"}]} 
SRT |a IMMACULADACARBONANDO2920