Dual-energy CT angiography of the lungs: Comparison of test bolus and bolus tracking techniques for the determination of scan delay
Objective: To prospectively compare test bolus and bolus tracking for the determination of scan delay of pulmonary dual-energy CT angiography in patients with suspected pulmonary embolism. Materials and methods: 60 consecutive patients referred for CTA for exclusion of PE were randomized either into...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
10 July 2010
|
| In: |
European journal of radiology
Year: 2012, Jahrgang: 81, Heft: 1, Pages: 132-138 |
| ISSN: | 1872-7727 |
| DOI: | 10.1016/j.ejrad.2010.06.023 |
| Online-Zugang: | Verlag, kostenfrei registrierungspflichtig, Volltext: http://dx.doi.org/10.1016/j.ejrad.2010.06.023 Verlag, kostenfrei registrierungspflichtig, Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X10002974 |
| Verfasserangaben: | Thomas Henzler, Mathias Meyer, Miriam Reichert, Radko Krissak, John W. Nance, Stefan Haneder, Stefan O. Schoenberg, Christian Fink |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1575008122 | ||
| 003 | DE-627 | ||
| 005 | 20220814140400.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180514s2010 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejrad.2010.06.023 |2 doi | |
| 035 | |a (DE-627)1575008122 | ||
| 035 | |a (DE-576)505008122 | ||
| 035 | |a (DE-599)BSZ505008122 | ||
| 035 | |a (OCoLC)1341009388 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Henzler, Thomas |d 1980- |e VerfasserIn |0 (DE-588)134001486 |0 (DE-627)559468415 |0 (DE-576)276829948 |4 aut | |
| 245 | 1 | 0 | |a Dual-energy CT angiography of the lungs |b Comparison of test bolus and bolus tracking techniques for the determination of scan delay |c Thomas Henzler, Mathias Meyer, Miriam Reichert, Radko Krissak, John W. Nance, Stefan Haneder, Stefan O. Schoenberg, Christian Fink |
| 264 | 1 | |c 10 July 2010 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 14.05.2018 | ||
| 520 | |a Objective: To prospectively compare test bolus and bolus tracking for the determination of scan delay of pulmonary dual-energy CT angiography in patients with suspected pulmonary embolism. Materials and methods: 60 consecutive patients referred for CTA for exclusion of PE were randomized either into a test bolus group or into a bolus tracking group. All exams were performed on a 64-channel dual source CT scanner. A standard single-acquisition dual-energy CTA was performed after injection of 100ml Iomeprol 400 followed by a saline chaser of 4ml/s. The scan delay was determined using either test bolus (n=30) or bolus tracking (n=30). Test bolus was performed using an additional 20ml Iomeprol 400 injected with a rate of 4ml/s during acquisition of a series of dynamic low-dose monitoring scans followed by injection of a saline bolus of 20ml using the same flow rate. For DECT angiography of the lungs 100ml Iomeprol 400 was injected with an injection rate of 4ml/s followed by a saline chaser of 20ml using the same flow rate. Attenuation profiles of different vascular segments (pulmonary arteries, pulmonary parenchyma, aorta, all 4 heart chambers) were measured to evaluate the timing techniques. Overall image quality of dual-energy “perfusion” maps and virtual 120kV CTA images was evaluated by two radiologists regarding the present of artifacts. Results: In all patients an adequate and homogeneous contrast enhancement of more than 400 Hounsfield units (HU) was achieved in the different vascular districts. No statistically significant difference between test bolus and bolus tracking was found regarding vessel attenuation or overall image quality. Conclusion: A homogeneous opacification of the different vascular territories and the pulmonary parenchyma as well as a sufficient image quality can be achieved with either bolus tracking or test bolus techniques. | ||
| 650 | 4 | |a Bolus tracking | |
| 650 | 4 | |a Contrast agent administration | |
| 650 | 4 | |a Dual-energy CT | |
| 650 | 4 | |a Pulmonary embolism | |
| 650 | 4 | |a Test bolus | |
| 700 | 1 | |a Meyer, Mathias |d 1986- |e VerfasserIn |0 (DE-588)1025310306 |0 (DE-627)722026021 |0 (DE-576)370193059 |4 aut | |
| 700 | 1 | |a Reichert, Miriam |d 1981- |e VerfasserIn |0 (DE-588)1030116652 |0 (DE-627)734811292 |0 (DE-576)377924830 |4 aut | |
| 700 | 1 | |a Kriššák, Radko |d 1980- |e VerfasserIn |0 (DE-588)133904091 |0 (DE-627)557959128 |0 (DE-576)276900936 |4 aut | |
| 700 | 1 | |a Haneder, Stefan |d 1981- |e VerfasserIn |0 (DE-588)136678335 |0 (DE-627)585462097 |0 (DE-576)287960943 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Fink, Christian |d 1971- |e VerfasserIn |0 (DE-588)121198014 |0 (DE-627)705299767 |0 (DE-576)292581882 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European journal of radiology |d Amsterdam [u.a.] : Elsevier Science, 1990 |g 81(2012), 1, Seite 132-138 |h Online-Ressource |w (DE-627)32044483X |w (DE-600)2005350-2 |w (DE-576)099718138 |x 1872-7727 |7 nnas |a Dual-energy CT angiography of the lungs Comparison of test bolus and bolus tracking techniques for the determination of scan delay |
| 773 | 1 | 8 | |g volume:81 |g year:2012 |g number:1 |g pages:132-138 |g extent:7 |a Dual-energy CT angiography of the lungs Comparison of test bolus and bolus tracking techniques for the determination of scan delay |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.ejrad.2010.06.023 |x Verlag |z kostenfrei registrierungspflichtig |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0720048X10002974 |x Verlag |z kostenfrei registrierungspflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180514 | ||
| 993 | |a Article | ||
| 994 | |a 2012 | ||
| 998 | |g 121198014 |a Fink, Christian |m 121198014:Fink, Christian |d 60000 |d 62900 |e 60000PF121198014 |e 62900PF121198014 |k 0/60000/ |k 1/60000/62900/ |p 8 |y j | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 7 | ||
| 998 | |g 136678335 |a Haneder, Stefan |m 136678335:Haneder, Stefan |d 60000 |d 62900 |e 60000PH136678335 |e 62900PH136678335 |k 0/60000/ |k 1/60000/62900/ |p 6 | ||
| 998 | |g 133904091 |a Kriššák, Radko |m 133904091:Kriššák, Radko |d 60000 |d 62900 |e 60000PK133904091 |e 62900PK133904091 |k 0/60000/ |k 1/60000/62900/ |p 4 | ||
| 998 | |g 1030116652 |a Reichert, Miriam |m 1030116652:Reichert, Miriam |d 60000 |d 62900 |e 60000PR1030116652 |e 62900PR1030116652 |k 0/60000/ |k 1/60000/62900/ |p 3 | ||
| 998 | |g 1025310306 |a Meyer, Mathias |m 1025310306:Meyer, Mathias |d 60000 |d 62900 |e 60000PM1025310306 |e 62900PM1025310306 |k 0/60000/ |k 1/60000/62900/ |p 2 | ||
| 998 | |g 134001486 |a Henzler, Thomas |m 134001486:Henzler, Thomas |d 60000 |e 60000PH134001486 |k 0/60000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1575008122 |e 300924424X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"doi":["10.1016/j.ejrad.2010.06.023"],"eki":["1575008122"]},"physDesc":[{"extent":"7 S."}],"relHost":[{"disp":"Dual-energy CT angiography of the lungs Comparison of test bolus and bolus tracking techniques for the determination of scan delayEuropean journal of radiology","recId":"32044483X","language":["eng"],"titleAlt":[{"title":"EJR"}],"type":{"media":"Online-Ressource","bibl":"periodical"},"pubHistory":["Nachgewiesen 10.1990 -"],"origin":[{"dateIssuedDisp":"1990-","publisher":"Elsevier Science","publisherPlace":"Amsterdam [u.a.]","dateIssuedKey":"1990"}],"title":[{"title_sort":"European journal of radiology","subtitle":"EJR","title":"European journal of radiology"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"extent":"7","issue":"1","text":"81(2012), 1, Seite 132-138","volume":"81","year":"2012","pages":"132-138"},"id":{"issn":["1872-7727"],"zdb":["2005350-2"],"eki":["32044483X"]},"note":["Gesehen am 05.02.20"]}],"note":["Gesehen am 14.05.2018"],"recId":"1575008122","origin":[{"dateIssuedDisp":"10 July 2010","dateIssuedKey":"2010"}],"name":{"displayForm":["Thomas Henzler, Mathias Meyer, Miriam Reichert, Radko Krissak, John W. Nance, Stefan Haneder, Stefan O. Schoenberg, Christian Fink"]},"person":[{"role":"aut","family":"Henzler","display":"Henzler, Thomas","given":"Thomas"},{"family":"Meyer","given":"Mathias","display":"Meyer, Mathias","role":"aut"},{"display":"Reichert, Miriam","given":"Miriam","family":"Reichert","role":"aut"},{"family":"Kriššák","display":"Kriššák, Radko","given":"Radko","role":"aut"},{"role":"aut","family":"Haneder","given":"Stefan","display":"Haneder, Stefan"},{"display":"Schönberg, Stefan","given":"Stefan","family":"Schönberg","role":"aut"},{"display":"Fink, Christian","given":"Christian","family":"Fink","role":"aut"}],"language":["eng"],"title":[{"title":"Dual-energy CT angiography of the lungs","subtitle":"Comparison of test bolus and bolus tracking techniques for the determination of scan delay","title_sort":"Dual-energy CT angiography of the lungs"}]} | ||
| SRT | |a HENZLERTHODUALENERGY1020 | ||