Heated air humidification versus cold air nebulization in newly tracheostomized patients

Background After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold-air nebulization versus heated high-flow humidification on...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Birk, Richard (VerfasserIn) , Schell, Angela (VerfasserIn) , Kramer, Benedikt (VerfasserIn) , Aderhold, Marc Christoph (VerfasserIn) , Hörmann, Karl (VerfasserIn) , Sommer, Ulrich (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 09 October 2017
In: Head & neck
Year: 2017, Jahrgang: 39, Heft: 12, Pages: 2481-2487
ISSN:1097-0347
DOI:10.1002/hed.24917
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1002/hed.24917
Verlag, Volltext: https://onlinelibrary-wiley-com.ezproxy.medma.uni-heidelberg.de/doi/abs/10.1002/hed.24917
Volltext
Verfasserangaben:Richard Birk MD, Alexander Händel, Angela Wenzel MD, Benedikt Kramer MD, Christoph Aderhold MD, Karl Hörmann MD, PhD, Boris A. Stuck MD, J. Ulrich Sommer MD, PhD

MARC

LEADER 00000caa a2200000 c 4500
001 1575164124
003 DE-627
005 20220814141751.0
007 cr uuu---uuuuu
008 180516s2017 xx |||||o 00| ||eng c
024 7 |a 10.1002/hed.24917  |2 doi 
035 |a (DE-627)1575164124 
035 |a (DE-576)505164124 
035 |a (DE-599)BSZ505164124 
035 |a (OCoLC)1341009736 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Birk, Richard  |d 1984-  |e VerfasserIn  |0 (DE-588)1033785636  |0 (DE-627)742508803  |0 (DE-576)381448746  |4 aut 
245 1 0 |a Heated air humidification versus cold air nebulization in newly tracheostomized patients  |c Richard Birk MD, Alexander Händel, Angela Wenzel MD, Benedikt Kramer MD, Christoph Aderhold MD, Karl Hörmann MD, PhD, Boris A. Stuck MD, J. Ulrich Sommer MD, PhD 
264 1 |c 09 October 2017 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 16.05.2018 
520 |a Background After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold-air nebulization versus heated high-flow humidification on medical interventions and tracheal ciliary beat frequency (CBF). Methods Newly tracheostomized patients (n = 20) were treated either with cold-air nebulization or heated humidification. The number of required tracheal suctioning procedures to clean the trachea and tracheal CBF were assessed. Results The number of required suctions per day was significantly lower in the heated humidification group with medians 3 versus 5 times per day. Mean CBF was significantly higher in the heated humidification group (6.36 ± 1.49 Hz) compared to the cold-air nebulization group (3.99 ± 1.39 Hz). Conclusion The data suggest that heated humidification enhanced mucociliary transport leading to a reduced number of required suctioning procedures in the trachea, which may improve postoperative patient care. 
650 4 |a humidification 
650 4 |a nurse care 
650 4 |a tracheostomy 
650 4 |a tracheostomy care ciliary beat frequency (CBF) 
700 1 |a Schell, Angela  |d 1985-  |e VerfasserIn  |0 (DE-588)1018415912  |0 (DE-627)682306142  |0 (DE-576)355745186  |4 aut 
700 1 |a Kramer, Benedikt  |d 1985-  |e VerfasserIn  |0 (DE-588)1067455698  |0 (DE-627)818750677  |0 (DE-576)42666048X  |4 aut 
700 1 |a Aderhold, Marc Christoph  |d 1984-  |e VerfasserIn  |0 (DE-588)1015507301  |0 (DE-627)66910700X  |0 (DE-576)350716404  |4 aut 
700 1 |a Hörmann, Karl  |d 1948-  |e VerfasserIn  |0 (DE-588)130123749  |0 (DE-627)49171193X  |0 (DE-576)266607438  |4 aut 
700 1 |a Sommer, Ulrich  |d 1980-  |e VerfasserIn  |0 (DE-588)143861298  |0 (DE-627)704624036  |0 (DE-576)339202696  |4 aut 
773 0 8 |i Enthalten in  |t Head & neck  |d New York, NY [u.a.] : Wiley Interscience, 1989  |g 39(2017), 12, Seite 2481-2487  |h Online-Ressource  |w (DE-627)313080429  |w (DE-600)2001440-5  |w (DE-576)114617406  |x 1097-0347  |7 nnas  |a Heated air humidification versus cold air nebulization in newly tracheostomized patients 
773 1 8 |g volume:39  |g year:2017  |g number:12  |g pages:2481-2487  |g extent:7  |a Heated air humidification versus cold air nebulization in newly tracheostomized patients 
856 4 0 |u http://dx.doi.org/10.1002/hed.24917  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary-wiley-com.ezproxy.medma.uni-heidelberg.de/doi/abs/10.1002/hed.24917  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180516 
993 |a Article 
994 |a 2017 
998 |g 143861298  |a Sommer, Ulrich  |m 143861298:Sommer, Ulrich  |d 60000  |d 62100  |e 60000PS143861298  |e 62100PS143861298  |k 0/60000/  |k 1/60000/62100/  |p 8  |y j 
998 |g 130123749  |a Hörmann, Karl  |m 130123749:Hörmann, Karl  |d 60000  |d 62100  |e 60000PH130123749  |e 62100PH130123749  |k 0/60000/  |k 1/60000/62100/  |p 5 
998 |g 1015507301  |a Aderhold, Marc Christoph  |m 1015507301:Aderhold, Marc Christoph  |d 60000  |d 62100  |e 60000PA1015507301  |e 62100PA1015507301  |k 0/60000/  |k 1/60000/62100/  |p 4 
998 |g 1067455698  |a Kramer, Benedikt  |m 1067455698:Kramer, Benedikt  |d 60000  |d 62100  |e 60000PK1067455698  |e 62100PK1067455698  |k 0/60000/  |k 1/60000/62100/  |p 3 
998 |g 1018415912  |a Schell, Angela  |m 1018415912:Schell, Angela  |d 60000  |d 62100  |e 60000PS1018415912  |e 62100PS1018415912  |k 0/60000/  |k 1/60000/62100/  |p 2 
998 |g 1033785636  |a Birk, Richard  |m 1033785636:Birk, Richard  |d 60000  |d 62100  |e 60000PB1033785636  |e 62100PB1033785636  |k 0/60000/  |k 1/60000/62100/  |p 1  |x j 
999 |a KXP-PPN1575164124  |e 300947802X 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"title":[{"title_sort":"Heated air humidification versus cold air nebulization in newly tracheostomized patients","title":"Heated air humidification versus cold air nebulization in newly tracheostomized patients"}],"person":[{"role":"aut","family":"Birk","given":"Richard","display":"Birk, Richard"},{"display":"Schell, Angela","given":"Angela","family":"Schell","role":"aut"},{"role":"aut","family":"Kramer","display":"Kramer, Benedikt","given":"Benedikt"},{"display":"Aderhold, Marc Christoph","given":"Marc Christoph","family":"Aderhold","role":"aut"},{"role":"aut","display":"Hörmann, Karl","given":"Karl","family":"Hörmann"},{"role":"aut","given":"Ulrich","display":"Sommer, Ulrich","family":"Sommer"}],"recId":"1575164124","origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"09 October 2017"}],"name":{"displayForm":["Richard Birk MD, Alexander Händel, Angela Wenzel MD, Benedikt Kramer MD, Christoph Aderhold MD, Karl Hörmann MD, PhD, Boris A. Stuck MD, J. Ulrich Sommer MD, PhD"]},"relHost":[{"pubHistory":["Volume 11, issue 1 (January/February 1989)-"],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Heated air humidification versus cold air nebulization in newly tracheostomized patientsHead & neck","recId":"313080429","language":["eng"],"titleAlt":[{"title":"Head and neck"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1097-0347"],"doi":["10.1002/(ISSN)1097-0347"],"zdb":["2001440-5"],"eki":["313080429"]},"part":{"pages":"2481-2487","year":"2017","text":"39(2017), 12, Seite 2481-2487","volume":"39","issue":"12","extent":"7"},"note":["Gesehen am 27.02.08"],"origin":[{"publisher":"Wiley Interscience","dateIssuedDisp":"1989-","dateIssuedKey":"1989","publisherPlace":"New York, NY [u.a.]"}],"title":[{"subtitle":"journal for the sciences and specialties of the head and neck","title_sort":"Head & neck","title":"Head & neck"}]}],"note":["Gesehen am 16.05.2018"],"physDesc":[{"extent":"7 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"doi":["10.1002/hed.24917"],"eki":["1575164124"]}} 
SRT |a BIRKRICHARHEATEDAIRH0920