Impact of an aortic nitinol stent graft on flow measurements by time-resolved three-dimensional velocity-encoded MRI

Rationale and Objectives Three-dimensional (3D) velocity-encoded cine (VEC) magnetic resonance imaging (MRI) has the potential to quantify 3D hemodynamic aspects known from computational fluid dynamics and to be used to identify hemodynamic risk factors for complications of endovascular aortic repai...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rengier, Fabian (VerfasserIn) , Ley, Sebastian (VerfasserIn) , Partovi, Sasan (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Tengg-Kobligk, Hendrik von (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2012
In: Academic radiology
Year: 2012, Jahrgang: 19, Heft: 3, Pages: 274-280
ISSN:1878-4046
DOI:10.1016/j.acra.2011.10.025
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1016/j.acra.2011.10.025
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S1076633211005125
Volltext
Verfasserangaben:Fabian Rengier, Michael Delles, Roland Unterhinninghofen, Sebastian Ley, Sasan Partovi, Rüdiger Dillmann, Hans-Ulrich Kauczor, Hendrik von Tengg-Kobligk

MARC

LEADER 00000caa a2200000 c 4500
001 1575271397
003 DE-627
005 20240316100352.0
007 cr uuu---uuuuu
008 180517s2012 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.acra.2011.10.025  |2 doi 
035 |a (DE-627)1575271397 
035 |a (DE-576)505271397 
035 |a (DE-599)BSZ505271397 
035 |a (OCoLC)1341009820 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Rengier, Fabian  |d 1986-  |e VerfasserIn  |0 (DE-588)139065865  |0 (DE-627)608103284  |0 (DE-576)309935873  |4 aut 
245 1 0 |a Impact of an aortic nitinol stent graft on flow measurements by time-resolved three-dimensional velocity-encoded MRI  |c Fabian Rengier, Michael Delles, Roland Unterhinninghofen, Sebastian Ley, Sasan Partovi, Rüdiger Dillmann, Hans-Ulrich Kauczor, Hendrik von Tengg-Kobligk 
264 1 |c 2012 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Available online 15 December 2011 
500 |a Gesehen am 17.05.2018 
520 |a Rationale and Objectives Three-dimensional (3D) velocity-encoded cine (VEC) magnetic resonance imaging (MRI) has the potential to quantify 3D hemodynamic aspects known from computational fluid dynamics and to be used to identify hemodynamic risk factors for complications of endovascular aortic repair. The purpose of this study was to investigate the impact of an aortic nickel-titanium (nitinol) stent graft on the accuracy of flow measurements by 3D VEC MRI. Materials and Methods A pump generated pulsatile aortic flow in an elastic tube phantom mimicking the aorta. Stacked two-dimensional three-directional VEC MRI (stacked-2D-3dir-MRI), 3D three-directional VEC MRI (3D-3dir-MRI), and gold-standard 2D through-plane VEC MRI were applied before and after the insertion of an aortic nitinol stent graft. Six equidistant levels were analyzed twice by the same reader. The percentage difference of the measured flow rate from the gold standard was defined as the parameter of accuracy. Results The overall accuracy of in-stent flow measurements related to the gold standard was −5.4% for stacked-2D-3dir-MRI and −4.1% for 3D-3dir-MRI, demonstrating significant overall underestimation compared to the gold standard (P = .016 and P = .013). However, flow measurements with the stent graft were significantly overestimated by 4.1% using stacked-2D-3dir-MRI (P < .001) and by 5.4% using 3D-3dir-MRI (P = .003) compared to identical measurements without the stent graft. In stacked-2D-3dir-MRI, this positive bias was significantly greater at the proximal and distal ends of the stent graft (P = .025). In 3D-3dir-MRI, measurements along the whole length of the stent graft were affected (P = .006). Intraobserver agreement was excellent, with intraclass correlation coefficients of 0.94 for stacked-2D-3dir-MRI (P < .001) and 0.90 for 3D-3dir-MRI (P < .001). Conclusions Flow measurements within an aortic nitinol stent graft by 3D VEC MRI are feasible, but stent grafts may cause a significant positive bias. 
650 4 |a aorta 
650 4 |a blood flow 
650 4 |a Magnetic resonance imaging 
650 4 |a stent graft 
650 4 |a three-dimensional imaging 
700 1 |a Ley, Sebastian  |d 1974-  |e VerfasserIn  |0 (DE-588)123561256  |0 (DE-627)706346858  |0 (DE-576)293766835  |4 aut 
700 1 |a Partovi, Sasan  |d 1986-  |e VerfasserIn  |0 (DE-588)1019808713  |0 (DE-627)687017564  |0 (DE-576)358894794  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Tengg-Kobligk, Hendrik von  |d 1972-  |e VerfasserIn  |0 (DE-588)129455733  |0 (DE-627)397663188  |0 (DE-576)297668501  |4 aut 
773 0 8 |i Enthalten in  |t Academic radiology  |d Philadelphia, PA [u.a.] : Elsevier, 1994  |g 19(2012), 3, Seite 274-280  |h Online-Ressource  |w (DE-627)331018667  |w (DE-600)2050425-1  |w (DE-576)271497602  |x 1878-4046  |7 nnas  |a Impact of an aortic nitinol stent graft on flow measurements by time-resolved three-dimensional velocity-encoded MRI 
773 1 8 |g volume:19  |g year:2012  |g number:3  |g pages:274-280  |g extent:7  |a Impact of an aortic nitinol stent graft on flow measurements by time-resolved three-dimensional velocity-encoded MRI 
856 4 0 |u http://dx.doi.org/10.1016/j.acra.2011.10.025  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://www.sciencedirect.com/science/article/pii/S1076633211005125  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180517 
993 |a Article 
994 |a 2012 
998 |g 129455733  |a Tengg-Kobligk, Hendrik von  |m 129455733:Tengg-Kobligk, Hendrik von  |d 50000  |e 50000PT129455733  |k 0/50000/  |p 8  |y j 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 1019808713  |a Partovi, Sasan  |m 1019808713:Partovi, Sasan  |p 5 
998 |g 123561256  |a Ley, Sebastian  |m 123561256:Ley, Sebastian  |p 4 
998 |g 139065865  |a Rengier, Fabian  |m 139065865:Rengier, Fabian  |d 910000  |d 911400  |e 910000PR139065865  |e 911400PR139065865  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1575271397  |e 3009723350 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Impact of an aortic nitinol stent graft on flow measurements by time-resolved three-dimensional velocity-encoded MRI","title":"Impact of an aortic nitinol stent graft on flow measurements by time-resolved three-dimensional velocity-encoded MRI"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Available online 15 December 2011","Gesehen am 17.05.2018"],"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012"}],"relHost":[{"note":["Gesehen am 18.04.17"],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"part":{"volume":"19","year":"2012","issue":"3","extent":"7","text":"19(2012), 3, Seite 274-280","pages":"274-280"},"title":[{"title":"Academic radiology","title_sort":"Academic radiology","subtitle":"official journal of the Association of University Radiologists, the Society of Chairs of Academic Radiology Departments, the Association of Program Directors in Radiology, the American Alliance of Academic Chief Residents in Radiology, the Alliance of Medical Student Educators in Radiology, the Radiology Research Alliance, the Radiology Alliance for Health Services Research, and the Medical Image Computing and Computer-Assisted Intervention Society"}],"id":{"zdb":["2050425-1"],"issn":["1878-4046"],"eki":["331018667"]},"pubHistory":["1.1994 -"],"origin":[{"publisher":"Elsevier ; Assoc. of University Radiologists","dateIssuedDisp":"1994-","dateIssuedKey":"1994","publisherPlace":"Philadelphia, PA [u.a.] ; Oak Brook, Ill."}],"disp":"Impact of an aortic nitinol stent graft on flow measurements by time-resolved three-dimensional velocity-encoded MRIAcademic radiology","physDesc":[{"extent":"Online-Ressource"}],"recId":"331018667"}],"person":[{"display":"Rengier, Fabian","role":"aut","given":"Fabian","family":"Rengier"},{"role":"aut","given":"Sebastian","family":"Ley","display":"Ley, Sebastian"},{"display":"Partovi, Sasan","family":"Partovi","role":"aut","given":"Sasan"},{"given":"Hans-Ulrich","role":"aut","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"display":"Tengg-Kobligk, Hendrik von","family":"Tengg-Kobligk","given":"Hendrik von","role":"aut"}],"recId":"1575271397","physDesc":[{"extent":"7 S."}],"id":{"eki":["1575271397"],"doi":["10.1016/j.acra.2011.10.025"]},"name":{"displayForm":["Fabian Rengier, Michael Delles, Roland Unterhinninghofen, Sebastian Ley, Sasan Partovi, Rüdiger Dillmann, Hans-Ulrich Kauczor, Hendrik von Tengg-Kobligk"]}} 
SRT |a RENGIERFABIMPACTOFAN2012