A fast inverse treatment planning strategy facilitating optimized catheter selection in image‐guided high‐dose‐rate interstitial gynecologic brachytherapy

Purpose Interstitial high?dose rate (HDR) brachytherapy is an important therapeutic strategy for the treatment of locally advanced gynecologic (GYN) cancers. The outcome of this therapy is determined by the quality of dose distribution achieved. This paper focuses on a novel yet simple heuristic for...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Guthier, Christian Vinzenz (VerfasserIn) , Hesser, Jürgen (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 18 September 2017
In: Medical physics
Year: 2017, Jahrgang: 44, Heft: 12, Pages: 6117-6127
ISSN:2473-4209
DOI:10.1002/mp.12590
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1002/mp.12590
Verlag, Volltext: https://aapm-onlinelibrary-wiley-com.ezproxy.medma.uni-heidelberg.de/doi/abs/10.1002/mp.12590
Volltext
Verfasserangaben:Guthier Christian V., Damato Antonio L., Hesser Juergen W., Viswanathan Akila N., Cormack Robert A.

MARC

LEADER 00000caa a2200000 c 4500
001 1575273853
003 DE-627
005 20230427042904.0
007 cr uuu---uuuuu
008 180517s2017 xx |||||o 00| ||eng c
024 7 |a 10.1002/mp.12590  |2 doi 
035 |a (DE-627)1575273853 
035 |a (DE-576)505273853 
035 |a (DE-599)BSZ505273853 
035 |a (OCoLC)1341009504 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Guthier, Christian Vinzenz  |e VerfasserIn  |0 (DE-588)1079608826  |0 (DE-627)841271291  |0 (DE-576)452828333  |4 aut 
245 1 2 |a A fast inverse treatment planning strategy facilitating optimized catheter selection in image‐guided high‐dose‐rate interstitial gynecologic brachytherapy  |c Guthier Christian V., Damato Antonio L., Hesser Juergen W., Viswanathan Akila N., Cormack Robert A. 
264 1 |c 18 September 2017 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 17.05.2018 
520 |a Purpose Interstitial high?dose rate (HDR) brachytherapy is an important therapeutic strategy for the treatment of locally advanced gynecologic (GYN) cancers. The outcome of this therapy is determined by the quality of dose distribution achieved. This paper focuses on a novel yet simple heuristic for catheter selection for GYN HDR brachytherapy and their comparison against state of the art optimization strategies. The proposed technique is intended to act as a decision?supporting tool to select a favorable needle configuration. Materials The presented heuristic for catheter optimization is based on a shrinkage?type algorithm (SACO). It is compared against state of the art planning in a retrospective study of 20 patients who previously received image?guided interstitial HDR brachytherapy using a Syed Neblett template. From those plans, template orientation and position are estimated via a rigid registration of the template with the actual catheter trajectories. All potential straight trajectories intersecting the contoured clinical target volume (CTV) are considered for catheter optimization. Retrospectively generated plans and clinical plans are compared with respect to dosimetric performance and optimization time. Results All plans were generated with one single run of the optimizer lasting 0.6?97.4 s. Compared to manual optimization, SACO yields a statistically significant (P ≤ 0.05) improved target coverage while at the same time fulfilling all dosimetric constraints for organs at risk (OARs). Comparing inverse planning strategies, dosimetric evaluation for SACO and ?hybrid inverse planning and optimization? (HIPO), as gold standard, shows no statistically significant difference (P > 0.05). However, SACO provides the potential to reduce the number of used catheters without compromising plan quality. Conclusion The proposed heuristic for needle selection provides fast catheter selection with optimization times suited for intraoperative treatment planning. Compared to manual optimization, the proposed methodology results in fewer catheters without a clinically significant loss in plan quality. The proposed approach can be used as a decision support tool that guides the user to find the ideal number and configuration of catheters. 
650 4 |a brachytherapy 
650 4 |a catheter optimization 
650 4 |a dosimetric measure 
650 4 |a gynecologic HDR 
650 4 |a inverse treatment planning 
700 1 |a Hesser, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1020647353  |0 (DE-627)691291071  |0 (DE-576)361513739  |4 aut 
773 0 8 |i Enthalten in  |t Medical physics  |d Hoboken, NJ : Wiley, 1974  |g 44(2017), 12, Seite 6117-6127  |h Online-Ressource  |w (DE-627)265784867  |w (DE-600)1466421-5  |w (DE-576)074891243  |x 2473-4209  |7 nnas  |a A fast inverse treatment planning strategy facilitating optimized catheter selection in image‐guided high‐dose‐rate interstitial gynecologic brachytherapy 
773 1 8 |g volume:44  |g year:2017  |g number:12  |g pages:6117-6127  |g extent:11  |a A fast inverse treatment planning strategy facilitating optimized catheter selection in image‐guided high‐dose‐rate interstitial gynecologic brachytherapy 
856 4 0 |u http://dx.doi.org/10.1002/mp.12590  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://aapm-onlinelibrary-wiley-com.ezproxy.medma.uni-heidelberg.de/doi/abs/10.1002/mp.12590  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180517 
993 |a Article 
994 |a 2017 
998 |g 1020647353  |a Hesser, Jürgen  |m 1020647353:Hesser, Jürgen  |d 60000  |d 63000  |e 60000PH1020647353  |e 63000PH1020647353  |k 0/60000/  |k 1/60000/63000/  |p 3 
999 |a KXP-PPN1575273853  |e 3009726910 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"family":"Guthier","display":"Guthier, Christian Vinzenz","given":"Christian Vinzenz","role":"aut"},{"role":"aut","given":"Jürgen","family":"Hesser","display":"Hesser, Jürgen"}],"language":["eng"],"note":["Gesehen am 17.05.2018"],"title":[{"title":"A fast inverse treatment planning strategy facilitating optimized catheter selection in image‐guided high‐dose‐rate interstitial gynecologic brachytherapy","title_sort":"fast inverse treatment planning strategy facilitating optimized catheter selection in image‐guided high‐dose‐rate interstitial gynecologic brachytherapy"}],"origin":[{"dateIssuedDisp":"18 September 2017","dateIssuedKey":"2017"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"recId":"1575273853","name":{"displayForm":["Guthier Christian V., Damato Antonio L., Hesser Juergen W., Viswanathan Akila N., Cormack Robert A."]},"physDesc":[{"extent":"11 S."}],"relHost":[{"language":["eng"],"origin":[{"dateIssuedKey":"1974","publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]","publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY","dateIssuedDisp":"1974-"}],"note":["Gesehen am 01.08.2025"],"titleAlt":[{"title":"Medical physics online"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title_sort":"Medical physics","title":"Medical physics"}],"part":{"issue":"12","year":"2017","pages":"6117-6127","text":"44(2017), 12, Seite 6117-6127","extent":"11","volume":"44"},"disp":"A fast inverse treatment planning strategy facilitating optimized catheter selection in image‐guided high‐dose‐rate interstitial gynecologic brachytherapyMedical physics","id":{"zdb":["1466421-5"],"issn":["2473-4209","1522-8541"],"eki":["265784867"]},"pubHistory":["1.1974 -"],"recId":"265784867","name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]},"physDesc":[{"extent":"Online-Ressource"}]}],"id":{"eki":["1575273853"],"doi":["10.1002/mp.12590"]}} 
SRT |a GUTHIERCHRFASTINVERS1820