Functional imaging of lung cancer using dual energy CT: how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT?

Objectives:To investigate the correlation between maximum standardized uptake value (SUVmax) of 18FDG PET-CT and iodine-related attenuation (IRA) of dual energy CT (DECT) of primary tumours and 18FDG PET-CT positive thoracic lymph nodes (LN) in patients with lung cancer.Methods37 patients with lung...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schmid-Bindert, Gerald (VerfasserIn) , Henzler, Thomas (VerfasserIn) , Meyer, Mathias (VerfasserIn) , Dinter, Dietmar (VerfasserIn) , Apfaltrer, Paul (VerfasserIn) , Kriššák, Radko (VerfasserIn) , Manegold, Christian (VerfasserIn) , Schönberg, Stefan (VerfasserIn) , Fink, Christian (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 7 August 2011
In: European radiology
Year: 2011, Jahrgang: 22, Heft: 1, Pages: 93-103
ISSN:1432-1084
DOI:10.1007/s00330-011-2230-3
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1007/s00330-011-2230-3
Verlag, Volltext: https://link.springer.com/article/10.1007/s00330-011-2230-3
Volltext
Verfasserangaben:G. Schmid-Bindert, Thomas Henzler, T.Q. Chu, M. Meyer, J.W. Nance, U.J. Schoepf, D.J. Dinter, P. Apfaltrer, R. Krissak, C. Manegold, S.O. Schoenberg, C. Fink

MARC

LEADER 00000caa a2200000 c 4500
001 1575288982
003 DE-627
005 20220814142927.0
007 cr uuu---uuuuu
008 180518r20122011xx |||||o 00| ||eng c
024 7 |a 10.1007/s00330-011-2230-3  |2 doi 
035 |a (DE-627)1575288982 
035 |a (DE-576)505288982 
035 |a (DE-599)BSZ505288982 
035 |a (OCoLC)1341009755 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schmid-Bindert, Gerald  |d 1969-  |e VerfasserIn  |0 (DE-588)121300129  |0 (DE-627)081214170  |0 (DE-576)292636024  |4 aut 
245 1 0 |a Functional imaging of lung cancer using dual energy CT  |b how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT?  |c G. Schmid-Bindert, Thomas Henzler, T.Q. Chu, M. Meyer, J.W. Nance, U.J. Schoepf, D.J. Dinter, P. Apfaltrer, R. Krissak, C. Manegold, S.O. Schoenberg, C. Fink 
264 1 |c 7 August 2011 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 18.05.2018 
520 |a Objectives:To investigate the correlation between maximum standardized uptake value (SUVmax) of 18FDG PET-CT and iodine-related attenuation (IRA) of dual energy CT (DECT) of primary tumours and 18FDG PET-CT positive thoracic lymph nodes (LN) in patients with lung cancer.Methods37 patients with lung cancer (27 NSCLC, 10 SCLC, 86 18FDG PET-CT positive thoracic LN) who underwent both 18FDG PET-CT and DECT were analyzed. The mean study interval between 18FDG PET-CT and DECT was ≤21 days in 17 patients. The mean and maximum IRA of DECT as well as of virtual unenhanced and virtual 120 kV images of DECT was analyzed and correlated to the SUVmax of 18FDG PET-CT in all tumours and 18FDG PET-CT positive thoracic lymph nodes. Further subgroup analysis was performed for histological subtypes in all groups.ResultsA moderate correlation was found between SUVmax and maximum IRA in all tumours (n = 37;r = 0.507;p = 0.025) whereas only weak or no correlation were found between SUVmax and all other DECT measurements. A strong correlation was found in patients with study intervals ≤21 days (n = 17; r = 0.768;p = 0.017). Analysis of histological subtypes of lung cancer showed a strong correlation between SUVmax and maximum IRA in the analysis of all patients with NSCLC (r = 0.785;p = 0.001) and in patients with NSCLC and study intervals ≤21 days (r = 0.876;p = 0.024).Thoracic LN showed moderate correlation between SUVmax and maximum IRA in patients with study intervals ≤21 days (r = 0.654; p = 0.010) whereas a weak correlation was found between SUVmax and maximum IRA in patients with study intervals >21 days (r = 0.299; p = 0.035).ConclusionsDECT could serve as a valuable functional imaging test for patients with NSCLC as the IRA of DECT correlates with SUVmax of 18FDG PET-CT. 
534 |c 2011 
700 1 |a Henzler, Thomas  |d 1980-  |e VerfasserIn  |0 (DE-588)134001486  |0 (DE-627)559468415  |0 (DE-576)276829948  |4 aut 
700 1 |a Meyer, Mathias  |d 1986-  |e VerfasserIn  |0 (DE-588)1025310306  |0 (DE-627)722026021  |0 (DE-576)370193059  |4 aut 
700 1 |a Dinter, Dietmar  |d 1968-  |e VerfasserIn  |0 (DE-588)138698813  |0 (DE-627)605258139  |0 (DE-576)308596269  |4 aut 
700 1 |a Apfaltrer, Paul  |d 1983-  |e VerfasserIn  |0 (DE-588)1025309898  |0 (DE-627)722024924  |0 (DE-576)370191757  |4 aut 
700 1 |a Kriššák, Radko  |d 1980-  |e VerfasserIn  |0 (DE-588)133904091  |0 (DE-627)557959128  |0 (DE-576)276900936  |4 aut 
700 1 |a Manegold, Christian  |d 1946-2022  |e VerfasserIn  |0 (DE-588)108614913  |0 (DE-627)490287360  |0 (DE-576)289617200  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Fink, Christian  |d 1971-  |e VerfasserIn  |0 (DE-588)121198014  |0 (DE-627)705299767  |0 (DE-576)292581882  |4 aut 
773 0 8 |i Enthalten in  |t European radiology  |d Berlin : Springer, 1991  |g 22(2012), 1, Seite 93-103  |h Online-Ressource  |w (DE-627)268757526  |w (DE-600)1472718-3  |w (DE-576)103868070  |x 1432-1084  |7 nnas  |a Functional imaging of lung cancer using dual energy CT how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT? 
773 1 8 |g volume:22  |g year:2012  |g number:1  |g pages:93-103  |g extent:11  |a Functional imaging of lung cancer using dual energy CT how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT? 
856 4 0 |u http://dx.doi.org/10.1007/s00330-011-2230-3  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://link.springer.com/article/10.1007/s00330-011-2230-3  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180518 
993 |a Article 
994 |a 2012 
998 |g 121198014  |a Fink, Christian  |m 121198014:Fink, Christian  |d 60000  |d 62900  |e 60000PF121198014  |e 62900PF121198014  |k 0/60000/  |k 1/60000/62900/  |p 12  |y j 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |e 60000PS131557912  |e 62900PS131557912  |k 0/60000/  |k 1/60000/62900/  |p 11 
998 |g 108614913  |a Manegold, Christian  |m 108614913:Manegold, Christian  |d 60000  |d 61800  |e 60000PM108614913  |e 61800PM108614913  |k 0/60000/  |k 1/60000/61800/  |p 10 
998 |g 133904091  |a Kriššák, Radko  |m 133904091:Kriššák, Radko  |d 60000  |d 62900  |e 60000PK133904091  |e 62900PK133904091  |k 0/60000/  |k 1/60000/62900/  |p 9 
998 |g 1025309898  |a Apfaltrer, Paul  |m 1025309898:Apfaltrer, Paul  |d 60000  |d 62900  |e 60000PA1025309898  |e 62900PA1025309898  |k 0/60000/  |k 1/60000/62900/  |p 8 
998 |g 138698813  |a Dinter, Dietmar  |m 138698813:Dinter, Dietmar  |d 60000  |d 62900  |e 60000PD138698813  |e 62900PD138698813  |k 0/60000/  |k 1/60000/62900/  |p 7 
998 |g 1025310306  |a Meyer, Mathias  |m 1025310306:Meyer, Mathias  |d 60000  |d 62900  |e 60000PM1025310306  |e 62900PM1025310306  |k 0/60000/  |k 1/60000/62900/  |p 4 
998 |g 134001486  |a Henzler, Thomas  |m 134001486:Henzler, Thomas  |d 60000  |e 60000PH134001486  |k 0/60000/  |p 2 
998 |g 121300129  |a Schmid-Bindert, Gerald  |m 121300129:Schmid-Bindert, Gerald  |d 60000  |d 61800  |e 60000PS121300129  |e 61800PS121300129  |k 0/60000/  |k 1/60000/61800/  |p 1  |x j 
999 |a KXP-PPN1575288982  |e 3009764669 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"7 August 2011"}],"relHost":[{"recId":"268757526","disp":"Functional imaging of lung cancer using dual energy CT how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT?European radiology","title":[{"title_sort":"European radiology","subtitle":"official organ of the European Association of Radiology","title":"European radiology"}],"part":{"issue":"1","volume":"22","extent":"11","pages":"93-103","text":"22(2012), 1, Seite 93-103","year":"2012"},"type":{"media":"Online-Ressource","bibl":"periodical"},"corporate":[{"display":"European Association of Radiology","role":"isb","roleDisplay":"Herausgebendes Organ"}],"language":["eng"],"pubHistory":["1.1991 -"],"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"origin":[{"publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1991-","dateIssuedKey":"1991","publisher":"Springer"}],"id":{"zdb":["1472718-3"],"issn":["1432-1084","1613-3757"],"eki":["268757526"]},"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}]}],"id":{"eki":["1575288982"],"doi":["10.1007/s00330-011-2230-3"]},"physDesc":[{"extent":"11 S."}],"note":["Gesehen am 18.05.2018"],"person":[{"role":"aut","display":"Schmid-Bindert, Gerald","given":"Gerald","family":"Schmid-Bindert","roleDisplay":"VerfasserIn"},{"family":"Henzler","roleDisplay":"VerfasserIn","given":"Thomas","role":"aut","display":"Henzler, Thomas"},{"roleDisplay":"VerfasserIn","family":"Meyer","given":"Mathias","role":"aut","display":"Meyer, Mathias"},{"family":"Dinter","roleDisplay":"VerfasserIn","given":"Dietmar","role":"aut","display":"Dinter, Dietmar"},{"roleDisplay":"VerfasserIn","family":"Apfaltrer","role":"aut","display":"Apfaltrer, Paul","given":"Paul"},{"roleDisplay":"VerfasserIn","family":"Kriššák","role":"aut","display":"Kriššák, Radko","given":"Radko"},{"family":"Manegold","roleDisplay":"VerfasserIn","role":"aut","display":"Manegold, Christian","given":"Christian"},{"role":"aut","display":"Schönberg, Stefan","given":"Stefan","family":"Schönberg","roleDisplay":"VerfasserIn"},{"given":"Christian","role":"aut","display":"Fink, Christian","family":"Fink","roleDisplay":"VerfasserIn"}],"name":{"displayForm":["G. Schmid-Bindert, Thomas Henzler, T.Q. Chu, M. Meyer, J.W. Nance, U.J. Schoepf, D.J. Dinter, P. Apfaltrer, R. Krissak, C. Manegold, S.O. Schoenberg, C. Fink"]},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1575288982","title":[{"title":"Functional imaging of lung cancer using dual energy CT","title_sort":"Functional imaging of lung cancer using dual energy CT","subtitle":"how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT?"}]} 
SRT |a SCHMIDBINDFUNCTIONAL7201