Functional imaging of lung cancer using dual energy CT: how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT?
Objectives:To investigate the correlation between maximum standardized uptake value (SUVmax) of 18FDG PET-CT and iodine-related attenuation (IRA) of dual energy CT (DECT) of primary tumours and 18FDG PET-CT positive thoracic lymph nodes (LN) in patients with lung cancer.Methods37 patients with lung...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
7 August 2011
|
| In: |
European radiology
Year: 2011, Jahrgang: 22, Heft: 1, Pages: 93-103 |
| ISSN: | 1432-1084 |
| DOI: | 10.1007/s00330-011-2230-3 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1007/s00330-011-2230-3 Verlag, Volltext: https://link.springer.com/article/10.1007/s00330-011-2230-3 |
| Verfasserangaben: | G. Schmid-Bindert, Thomas Henzler, T.Q. Chu, M. Meyer, J.W. Nance, U.J. Schoepf, D.J. Dinter, P. Apfaltrer, R. Krissak, C. Manegold, S.O. Schoenberg, C. Fink |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1575288982 | ||
| 003 | DE-627 | ||
| 005 | 20220814142927.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180518r20122011xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00330-011-2230-3 |2 doi | |
| 035 | |a (DE-627)1575288982 | ||
| 035 | |a (DE-576)505288982 | ||
| 035 | |a (DE-599)BSZ505288982 | ||
| 035 | |a (OCoLC)1341009755 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Schmid-Bindert, Gerald |d 1969- |e VerfasserIn |0 (DE-588)121300129 |0 (DE-627)081214170 |0 (DE-576)292636024 |4 aut | |
| 245 | 1 | 0 | |a Functional imaging of lung cancer using dual energy CT |b how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT? |c G. Schmid-Bindert, Thomas Henzler, T.Q. Chu, M. Meyer, J.W. Nance, U.J. Schoepf, D.J. Dinter, P. Apfaltrer, R. Krissak, C. Manegold, S.O. Schoenberg, C. Fink |
| 264 | 1 | |c 7 August 2011 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 18.05.2018 | ||
| 520 | |a Objectives:To investigate the correlation between maximum standardized uptake value (SUVmax) of 18FDG PET-CT and iodine-related attenuation (IRA) of dual energy CT (DECT) of primary tumours and 18FDG PET-CT positive thoracic lymph nodes (LN) in patients with lung cancer.Methods37 patients with lung cancer (27 NSCLC, 10 SCLC, 86 18FDG PET-CT positive thoracic LN) who underwent both 18FDG PET-CT and DECT were analyzed. The mean study interval between 18FDG PET-CT and DECT was ≤21 days in 17 patients. The mean and maximum IRA of DECT as well as of virtual unenhanced and virtual 120 kV images of DECT was analyzed and correlated to the SUVmax of 18FDG PET-CT in all tumours and 18FDG PET-CT positive thoracic lymph nodes. Further subgroup analysis was performed for histological subtypes in all groups.ResultsA moderate correlation was found between SUVmax and maximum IRA in all tumours (n = 37;r = 0.507;p = 0.025) whereas only weak or no correlation were found between SUVmax and all other DECT measurements. A strong correlation was found in patients with study intervals ≤21 days (n = 17; r = 0.768;p = 0.017). Analysis of histological subtypes of lung cancer showed a strong correlation between SUVmax and maximum IRA in the analysis of all patients with NSCLC (r = 0.785;p = 0.001) and in patients with NSCLC and study intervals ≤21 days (r = 0.876;p = 0.024).Thoracic LN showed moderate correlation between SUVmax and maximum IRA in patients with study intervals ≤21 days (r = 0.654; p = 0.010) whereas a weak correlation was found between SUVmax and maximum IRA in patients with study intervals >21 days (r = 0.299; p = 0.035).ConclusionsDECT could serve as a valuable functional imaging test for patients with NSCLC as the IRA of DECT correlates with SUVmax of 18FDG PET-CT. | ||
| 534 | |c 2011 | ||
| 700 | 1 | |a Henzler, Thomas |d 1980- |e VerfasserIn |0 (DE-588)134001486 |0 (DE-627)559468415 |0 (DE-576)276829948 |4 aut | |
| 700 | 1 | |a Meyer, Mathias |d 1986- |e VerfasserIn |0 (DE-588)1025310306 |0 (DE-627)722026021 |0 (DE-576)370193059 |4 aut | |
| 700 | 1 | |a Dinter, Dietmar |d 1968- |e VerfasserIn |0 (DE-588)138698813 |0 (DE-627)605258139 |0 (DE-576)308596269 |4 aut | |
| 700 | 1 | |a Apfaltrer, Paul |d 1983- |e VerfasserIn |0 (DE-588)1025309898 |0 (DE-627)722024924 |0 (DE-576)370191757 |4 aut | |
| 700 | 1 | |a Kriššák, Radko |d 1980- |e VerfasserIn |0 (DE-588)133904091 |0 (DE-627)557959128 |0 (DE-576)276900936 |4 aut | |
| 700 | 1 | |a Manegold, Christian |d 1946-2022 |e VerfasserIn |0 (DE-588)108614913 |0 (DE-627)490287360 |0 (DE-576)289617200 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Fink, Christian |d 1971- |e VerfasserIn |0 (DE-588)121198014 |0 (DE-627)705299767 |0 (DE-576)292581882 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t European radiology |d Berlin : Springer, 1991 |g 22(2012), 1, Seite 93-103 |h Online-Ressource |w (DE-627)268757526 |w (DE-600)1472718-3 |w (DE-576)103868070 |x 1432-1084 |7 nnas |a Functional imaging of lung cancer using dual energy CT how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT? |
| 773 | 1 | 8 | |g volume:22 |g year:2012 |g number:1 |g pages:93-103 |g extent:11 |a Functional imaging of lung cancer using dual energy CT how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT? |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00330-011-2230-3 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://link.springer.com/article/10.1007/s00330-011-2230-3 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180518 | ||
| 993 | |a Article | ||
| 994 | |a 2012 | ||
| 998 | |g 121198014 |a Fink, Christian |m 121198014:Fink, Christian |d 60000 |d 62900 |e 60000PF121198014 |e 62900PF121198014 |k 0/60000/ |k 1/60000/62900/ |p 12 |y j | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 11 | ||
| 998 | |g 108614913 |a Manegold, Christian |m 108614913:Manegold, Christian |d 60000 |d 61800 |e 60000PM108614913 |e 61800PM108614913 |k 0/60000/ |k 1/60000/61800/ |p 10 | ||
| 998 | |g 133904091 |a Kriššák, Radko |m 133904091:Kriššák, Radko |d 60000 |d 62900 |e 60000PK133904091 |e 62900PK133904091 |k 0/60000/ |k 1/60000/62900/ |p 9 | ||
| 998 | |g 1025309898 |a Apfaltrer, Paul |m 1025309898:Apfaltrer, Paul |d 60000 |d 62900 |e 60000PA1025309898 |e 62900PA1025309898 |k 0/60000/ |k 1/60000/62900/ |p 8 | ||
| 998 | |g 138698813 |a Dinter, Dietmar |m 138698813:Dinter, Dietmar |d 60000 |d 62900 |e 60000PD138698813 |e 62900PD138698813 |k 0/60000/ |k 1/60000/62900/ |p 7 | ||
| 998 | |g 1025310306 |a Meyer, Mathias |m 1025310306:Meyer, Mathias |d 60000 |d 62900 |e 60000PM1025310306 |e 62900PM1025310306 |k 0/60000/ |k 1/60000/62900/ |p 4 | ||
| 998 | |g 134001486 |a Henzler, Thomas |m 134001486:Henzler, Thomas |d 60000 |e 60000PH134001486 |k 0/60000/ |p 2 | ||
| 998 | |g 121300129 |a Schmid-Bindert, Gerald |m 121300129:Schmid-Bindert, Gerald |d 60000 |d 61800 |e 60000PS121300129 |e 61800PS121300129 |k 0/60000/ |k 1/60000/61800/ |p 1 |x j | ||
| 999 | |a KXP-PPN1575288982 |e 3009764669 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"7 August 2011"}],"relHost":[{"recId":"268757526","disp":"Functional imaging of lung cancer using dual energy CT how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT?European radiology","title":[{"title_sort":"European radiology","subtitle":"official organ of the European Association of Radiology","title":"European radiology"}],"part":{"issue":"1","volume":"22","extent":"11","pages":"93-103","text":"22(2012), 1, Seite 93-103","year":"2012"},"type":{"media":"Online-Ressource","bibl":"periodical"},"corporate":[{"display":"European Association of Radiology","role":"isb","roleDisplay":"Herausgebendes Organ"}],"language":["eng"],"pubHistory":["1.1991 -"],"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 06.02.2018","Ungezählte Beil.: Supplement"],"origin":[{"publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1991-","dateIssuedKey":"1991","publisher":"Springer"}],"id":{"zdb":["1472718-3"],"issn":["1432-1084","1613-3757"],"eki":["268757526"]},"titleAlt":[{"title":"European radiology / Supplement"},{"title":"European radiology supplements"}]}],"id":{"eki":["1575288982"],"doi":["10.1007/s00330-011-2230-3"]},"physDesc":[{"extent":"11 S."}],"note":["Gesehen am 18.05.2018"],"person":[{"role":"aut","display":"Schmid-Bindert, Gerald","given":"Gerald","family":"Schmid-Bindert","roleDisplay":"VerfasserIn"},{"family":"Henzler","roleDisplay":"VerfasserIn","given":"Thomas","role":"aut","display":"Henzler, Thomas"},{"roleDisplay":"VerfasserIn","family":"Meyer","given":"Mathias","role":"aut","display":"Meyer, Mathias"},{"family":"Dinter","roleDisplay":"VerfasserIn","given":"Dietmar","role":"aut","display":"Dinter, Dietmar"},{"roleDisplay":"VerfasserIn","family":"Apfaltrer","role":"aut","display":"Apfaltrer, Paul","given":"Paul"},{"roleDisplay":"VerfasserIn","family":"Kriššák","role":"aut","display":"Kriššák, Radko","given":"Radko"},{"family":"Manegold","roleDisplay":"VerfasserIn","role":"aut","display":"Manegold, Christian","given":"Christian"},{"role":"aut","display":"Schönberg, Stefan","given":"Stefan","family":"Schönberg","roleDisplay":"VerfasserIn"},{"given":"Christian","role":"aut","display":"Fink, Christian","family":"Fink","roleDisplay":"VerfasserIn"}],"name":{"displayForm":["G. Schmid-Bindert, Thomas Henzler, T.Q. Chu, M. Meyer, J.W. Nance, U.J. Schoepf, D.J. Dinter, P. Apfaltrer, R. Krissak, C. Manegold, S.O. Schoenberg, C. Fink"]},"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"recId":"1575288982","title":[{"title":"Functional imaging of lung cancer using dual energy CT","title_sort":"Functional imaging of lung cancer using dual energy CT","subtitle":"how does iodine related attenuation correlate with standardized uptake value of 18FDG-PET-CT?"}]} | ||
| SRT | |a SCHMIDBINDFUNCTIONAL7201 | ||