Tribologische Messungen am Gelenkknorpel: ein Prüfstand zur Messung der Reibungszahlen von Knorpel gegen Knorpel, Regeneraten und TE-Konstrukten und erste Ergebnisse

Values for the friction coefficient of articular cartilage are given in ranges of percentage and lower and are calculated as a quotient of the friction force and the perpendicular loading force acting on it. Thus, a sophisticated system has to be provided for analysing the friction coefficient under...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schwarz, Markus (VerfasserIn) , Schneider-Wald, Barbara Katharina (VerfasserIn) , Krase, Anika (VerfasserIn) , Richter, Wiltrud (VerfasserIn) , Reisig, Gregor (VerfasserIn) , Kreinest, Michael (VerfasserIn) , Heute, Steffen (VerfasserIn) , Pott, Peter Paul (VerfasserIn) , Brade, Joachim (VerfasserIn) , Schütte, Andy (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Deutsch
Veröffentlicht: 04 October 2012
In: Der Orthopäde
Year: 2012, Jahrgang: 41, Heft: 10, Pages: 827-836
ISSN:1433-0431
DOI:10.1007/s00132-012-1951-6
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1007/s00132-012-1951-6
Verlag, Volltext: https://link.springer.com/article/10.1007/s00132-012-1951-6
Volltext
Verfasserangaben:M.L.R. Schwarz, B. Schneider-Wald, A. Krase, W. Richter, G. Reisig, M. Kreinest, S. Heute, P.P. Pott, J. Brade, A. Schütte
Beschreibung
Zusammenfassung:Values for the friction coefficient of articular cartilage are given in ranges of percentage and lower and are calculated as a quotient of the friction force and the perpendicular loading force acting on it. Thus, a sophisticated system has to be provided for analysing the friction coefficient under different conditions in particular when cartilage should be coupled as friction partner. It is possible to deep-freeze articular cartilage before measuring the friction coefficient as the procedure has no influence on the results. The presented tribological system was able to distinguish between altered and native cartilage. Furthermore, tissue engineered constructs for cartilage repair were differentiated from native cartilage probes by their friction coefficient. In conclusion a tribological equipment is presented to analyze the friction coefficient of articular cartilage, in vivo generated cartilage regenerates and in vitro tissue engineered constructs regarding their biomechanical properties for quality assessment.
Beschreibung:Gesehen am 28.05.2018
Beschreibung:Online Resource
ISSN:1433-0431
DOI:10.1007/s00132-012-1951-6