IGRT versus non-IGRT for postoperative head-and-neck IMRT patients: dosimetric consequences arising from a PTV margin reduction

Background To evaluate the impact of image-guided radiation therapy (IGRT) versus non-image-guided radiation therapy (non-IGRT) on the dose to the clinical target volume (CTV) and the cervical spinal cord during fractionated intensity-modulated radiation therapy (IMRT) for head-and-neck cancer (HNC...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schwarz, Michael (VerfasserIn) , Huber, Peter E. (VerfasserIn) , Debus, Jürgen (VerfasserIn) , Stoiber, Eva Maria (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: Aug 8, 2012
In: Radiation oncology
Year: 2012, Jahrgang: 7
ISSN:1748-717X
DOI:10.1186/1748-717X-7-133
Online-Zugang:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1186/1748-717X-7-133
Verlag, kostenfrei, Volltext: https://ro-journal.biomedcentral.com/articles/10.1186/1748-717X-7-133
Volltext
Verfasserangaben:Michael Schwarz, Kristina Giske, Armin Stoll, Simeon Nill, Peter E. Huber, Jürgen Debus, Rolf Bendl and Eva M. Stoiber

MARC

LEADER 00000caa a2200000 c 4500
001 1575842866
003 DE-627
005 20241009131337.0
007 cr uuu---uuuuu
008 180530s2012 xx |||||o 00| ||eng c
024 7 |a 10.1186/1748-717X-7-133  |2 doi 
035 |a (DE-627)1575842866 
035 |a (DE-576)505842866 
035 |a (DE-599)BSZ505842866 
035 |a (OCoLC)1341010327 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schwarz, Michael  |e VerfasserIn  |0 (DE-588)1129192822  |0 (DE-627)883831031  |0 (DE-576)486256073  |4 aut 
245 1 0 |a IGRT versus non-IGRT for postoperative head-and-neck IMRT patients  |b dosimetric consequences arising from a PTV margin reduction  |c Michael Schwarz, Kristina Giske, Armin Stoll, Simeon Nill, Peter E. Huber, Jürgen Debus, Rolf Bendl and Eva M. Stoiber 
264 1 |c Aug 8, 2012 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 30.05.2018 
520 |a Background To evaluate the impact of image-guided radiation therapy (IGRT) versus non-image-guided radiation therapy (non-IGRT) on the dose to the clinical target volume (CTV) and the cervical spinal cord during fractionated intensity-modulated radiation therapy (IMRT) for head-and-neck cancer (HNC) patients. Material and Methods For detailed investigation, 4 exemplary patients with daily control-CT scans (total 118 CT scans) were analyzed. For the IGRT approach a target point correction (TPC) derived from a rigid registration focused to the high-dose region was used. In the non-IGRT setting, instead of a TPC, an additional cohort-based safety margin was applied. The dose distributions of the CTV and spinal cord were calculated on each control-CT and the resulting dose volume histograms (DVHs) were compared with the planned ones fraction by fraction. The D50 and D98 values for the CTV and the D5 values of the spinal cord were additionally reported. Results In general, the D50 and D98 histograms show no remarkable difference between both strategies. Yet, our detailed analysis also reveals differences in individual dose coverage worth inspection. Using IGRT, the D5 histograms show that the spinal cord less frequently receives a higher dose than planned compared to the non-IGRT setting. This effect is even more pronounced when looking at the curve progressions of the respective DVHs. Conclusions Both approaches are equally effective in maintaining CTV coverage. However, IGRT is beneficial in spinal cord sparing. The use of an additional margin in the non-IGRT approach frequently results in a higher dose to the spinal cord than originally planned. This implies that a margin reduction combined with an IGRT correction helps to maintain spinal cord dose sparing best as possible. Yet, a detailed analysis of the dosimetric consequences dependent on the used strategy is required, to detect single fractions with unacceptable dosimetric deviations. 
700 1 |a Huber, Peter E.  |d 1965-  |e VerfasserIn  |0 (DE-588)1074678869  |0 (DE-627)832350109  |0 (DE-576)442767803  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Stoiber, Eva Maria  |d 1977-  |e VerfasserIn  |0 (DE-588)133358968  |0 (DE-627)543659216  |0 (DE-576)267834047  |4 aut 
773 0 8 |i Enthalten in  |t Radiation oncology  |d London : BioMed Central, 2006  |g 7(2012) Artikel-Nummer 133, 7 Seiten  |h Online-Ressource  |w (DE-627)508725739  |w (DE-600)2224965-5  |w (DE-576)260614815  |x 1748-717X  |7 nnas  |a IGRT versus non-IGRT for postoperative head-and-neck IMRT patients dosimetric consequences arising from a PTV margin reduction 
773 1 8 |g volume:7  |g year:2012  |g extent:7  |a IGRT versus non-IGRT for postoperative head-and-neck IMRT patients dosimetric consequences arising from a PTV margin reduction 
856 4 0 |u http://dx.doi.org/10.1186/1748-717X-7-133  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://ro-journal.biomedcentral.com/articles/10.1186/1748-717X-7-133  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20180530 
993 |a Article 
994 |a 2012 
998 |g 133358968  |a Stoiber, Eva Maria  |m 133358968:Stoiber, Eva Maria  |d 910000  |d 912000  |e 910000PS133358968  |e 912000PS133358968  |k 0/910000/  |k 1/910000/912000/  |p 8  |y j 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 912000  |e 910000PD1022671421  |e 912000PD1022671421  |k 0/910000/  |k 1/910000/912000/  |p 6 
998 |g 1074678869  |a Huber, Peter E.  |m 1074678869:Huber, Peter E.  |d 50000  |e 50000PH1074678869  |k 0/50000/  |p 5 
999 |a KXP-PPN1575842866  |e 3010799918 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"extent":"7 S."}],"recId":"1575842866","note":["Gesehen am 30.05.2018"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"title":[{"subtitle":"dosimetric consequences arising from a PTV margin reduction","title_sort":"IGRT versus non-IGRT for postoperative head-and-neck IMRT patients","title":"IGRT versus non-IGRT for postoperative head-and-neck IMRT patients"}],"person":[{"display":"Schwarz, Michael","role":"aut","given":"Michael","family":"Schwarz"},{"display":"Huber, Peter E.","family":"Huber","given":"Peter E.","role":"aut"},{"display":"Debus, Jürgen","role":"aut","given":"Jürgen","family":"Debus"},{"display":"Stoiber, Eva Maria","family":"Stoiber","given":"Eva Maria","role":"aut"}],"relHost":[{"recId":"508725739","physDesc":[{"extent":"Online-Ressource"}],"disp":"IGRT versus non-IGRT for postoperative head-and-neck IMRT patients dosimetric consequences arising from a PTV margin reductionRadiation oncology","origin":[{"dateIssuedKey":"2006","publisherPlace":"London","dateIssuedDisp":"2006-","publisher":"BioMed Central"}],"pubHistory":["1.2006 -"],"id":{"zdb":["2224965-5"],"issn":["1748-717X"],"eki":["508725739"]},"title":[{"title_sort":"Radiation oncology","title":"Radiation oncology"}],"part":{"volume":"7","text":"7(2012) Artikel-Nummer 133, 7 Seiten","extent":"7","year":"2012"},"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"note":["Gesehen am 06.09.10"]}],"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"Aug 8, 2012"}],"id":{"doi":["10.1186/1748-717X-7-133"],"eki":["1575842866"]},"name":{"displayForm":["Michael Schwarz, Kristina Giske, Armin Stoll, Simeon Nill, Peter E. Huber, Jürgen Debus, Rolf Bendl and Eva M. Stoiber"]}} 
SRT |a SCHWARZMICIGRTVERSUS8201