A prospective, randomized comparison of 3 types of proximal interphalangeal joint arthroplasty

Purpose For surface replacement arthroplasty in proximal interphalangeal joint osteoarthritis, titanium-polyethylene (TI) and pyrocarbon (PY) implants are frequently used. However, their superiority in comparison to the silicone (SI) spacer has not been established. The purpose of this study was to...

Full description

Saved in:
Bibliographic Details
Main Authors: Daecke, Wolfgang Heinz Manfred (Author) , Kaszap, Balázs (Author) , Martini, Abdul-Kader (Author) , Hagena, Frank-Wolfgang (Author) , Jung, Martin (Author)
Format: Article (Journal)
Language:English
Published: 20 August 2012
In: The journal of hand surgery. [American volume]
Year: 2012, Volume: 37, Issue: 9, Pages: 1770-1779.e3
ISSN:1531-6564
DOI:10.1016/j.jhsa.2012.06.006
Online Access:Verlag, Volltext: http://dx.doi.org/10.1016/j.jhsa.2012.06.006
Verlag, Volltext: http://linkinghub.elsevier.com/retrieve/pii/S0363502312008337
Get full text
Author Notes:W. Daecke, B. Kaszap, A.K. Martini, F.W. Hagena, B. Rieck, M. Jung

MARC

LEADER 00000caa a2200000 c 4500
001 1575904020
003 DE-627
005 20220814152342.0
007 cr uuu---uuuuu
008 180601s2012 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jhsa.2012.06.006  |2 doi 
035 |a (DE-627)1575904020 
035 |a (DE-576)505904020 
035 |a (DE-599)BSZ505904020 
035 |a (OCoLC)1341010485 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Daecke, Wolfgang Heinz Manfred  |d 1967-  |e VerfasserIn  |0 (DE-588)120690845  |0 (DE-627)080831923  |0 (DE-576)292340273  |4 aut 
245 1 2 |a A prospective, randomized comparison of 3 types of proximal interphalangeal joint arthroplasty  |c W. Daecke, B. Kaszap, A.K. Martini, F.W. Hagena, B. Rieck, M. Jung 
264 1 |c 20 August 2012 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 01.06.2018 
520 |a Purpose For surface replacement arthroplasty in proximal interphalangeal joint osteoarthritis, titanium-polyethylene (TI) and pyrocarbon (PY) implants are frequently used. However, their superiority in comparison to the silicone (SI) spacer has not been established. The purpose of this study was to compare these 3 types of implants with regard to outcome. Methods A prospective, randomized, multicenter trial was performed. A total of 43 patients (62 proximal interphalangeal joints) had surgery in the 3 participating centers, and each patient was randomly allocated to one of the 3 groups (TI, PY, SI). Range of motion (ROM) and strength were measured before surgery; pain and disability self-assessment and radiographic analysis were also completed. The same examination protocol was planned for 3 months, 6 months, and 1, 2, and 3 years after surgery, but some follow-up visits did not take place due to patient death or poor compliance. Results The mean follow-up time at the final follow-up was 35 Ϯ 3 months (range, 30 - 41 mo). All implant types led to significant pain reduction at rest and at load. Tip pinch strength was slightly improved by all 3 devices at the 3-year follow-up. No significant improvement in ROM for silicone or resurfacing implants was found. However, when comparing the highest ROM values reached after surgery, the resurfacing devices tended to show superior joint motility compared to silicone spacers, albeit only temporarily and not significantly. Sixteen explantations were necessary: 2 of 18 SI (11%), 7 of 26 TI (27%) and 7 of 18 PY (39%) implants had to be removed. An additional 4 secondary surgical procedures were performed in group TI. Conclusions Surface replacement arthroplasty devices showed a tendency for a temporarily superior maximum postoperative ROM, but markedly higher postoperative complication and explantation rates were observed compared to the silicone spacer implantation. (J Hand Surg 2012;37A:1770-1779. Copyright © 2012 by the American Society for Surgery of the Hand. All rights reserved.) 
700 1 |a Kaszap, Balázs  |d 1983-  |e VerfasserIn  |0 (DE-588)1052436218  |0 (DE-627)788492799  |0 (DE-576)408149582  |4 aut 
700 1 |a Martini, Abdul-Kader  |d 1942-  |e VerfasserIn  |0 (DE-588)112140386  |0 (DE-627)584886497  |0 (DE-576)165831073  |4 aut 
700 1 |a Hagena, Frank-Wolfgang  |d 1945-  |e VerfasserIn  |0 (DE-588)108621626  |0 (DE-627)691013837  |0 (DE-576)348541376  |4 aut 
700 1 |a Jung, Martin  |e VerfasserIn  |0 (DE-588)1075471753  |0 (DE-627)833292935  |0 (DE-576)443488258  |4 aut 
773 0 8 |i Enthalten in  |t The journal of hand surgery. [American volume]  |d Amsterdam [u.a.] : Elsevier, 1976  |g 37(2012), 9, Seite 1770-1779.e3  |h Online-Ressource  |w (DE-627)320626709  |w (DE-600)2023397-8  |w (DE-576)091174082  |x 1531-6564  |7 nnas  |a A prospective, randomized comparison of 3 types of proximal interphalangeal joint arthroplasty 
773 1 8 |g volume:37  |g year:2012  |g number:9  |g pages:1770-1779.e3  |g extent:10  |a A prospective, randomized comparison of 3 types of proximal interphalangeal joint arthroplasty 
856 4 0 |u http://dx.doi.org/10.1016/j.jhsa.2012.06.006  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://linkinghub.elsevier.com/retrieve/pii/S0363502312008337  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180601 
993 |a Article 
994 |a 2012 
998 |g 1075471753  |a Jung, Martin  |m 1075471753:Jung, Martin  |d 910000  |d 911460  |e 910000PJ1075471753  |e 911460PJ1075471753  |k 0/910000/  |k 1/910000/911460/  |p 6  |y j 
998 |g 112140386  |a Martini, Abdul-Kader  |m 112140386:Martini, Abdul-Kader 
998 |g 1052436218  |a Kaszap, Balázs  |m 1052436218:Kaszap, Balázs  |d 910000  |d 911460  |e 910000PK1052436218  |e 911460PK1052436218  |k 0/910000/  |k 1/910000/911460/  |p 2 
998 |g 120690845  |a Daecke, Wolfgang Heinz Manfred  |m 120690845:Daecke, Wolfgang Heinz Manfred  |p 1  |x j 
999 |a KXP-PPN1575904020  |e 3011207402 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"given":"Wolfgang Heinz Manfred","family":"Daecke","role":"aut","display":"Daecke, Wolfgang Heinz Manfred","roleDisplay":"VerfasserIn"},{"given":"Balázs","family":"Kaszap","role":"aut","roleDisplay":"VerfasserIn","display":"Kaszap, Balázs"},{"given":"Abdul-Kader","family":"Martini","role":"aut","display":"Martini, Abdul-Kader","roleDisplay":"VerfasserIn"},{"given":"Frank-Wolfgang","family":"Hagena","role":"aut","roleDisplay":"VerfasserIn","display":"Hagena, Frank-Wolfgang"},{"roleDisplay":"VerfasserIn","display":"Jung, Martin","role":"aut","family":"Jung","given":"Martin"}],"title":[{"title_sort":"prospective, randomized comparison of 3 types of proximal interphalangeal joint arthroplasty","title":"A prospective, randomized comparison of 3 types of proximal interphalangeal joint arthroplasty"}],"recId":"1575904020","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Gesehen am 01.06.2018"],"name":{"displayForm":["W. Daecke, B. Kaszap, A.K. Martini, F.W. Hagena, B. Rieck, M. Jung"]},"id":{"eki":["1575904020"],"doi":["10.1016/j.jhsa.2012.06.006"]},"origin":[{"dateIssuedDisp":"20 August 2012","dateIssuedKey":"2012"}],"relHost":[{"origin":[{"dateIssuedDisp":"1976-","publisher":"Elsevier ; Saunders","dateIssuedKey":"1976","publisherPlace":"Amsterdam [u.a.] ; Orlando, Fla."}],"id":{"eki":["320626709"],"zdb":["2023397-8"],"issn":["1531-6564"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"partname":"[American volume] / American Society for Surgery of the Hand","title_sort":"journal of hand surgery","title":"The journal of hand surgery"}],"note":["Gesehen am 28.05.2024"],"disp":"A prospective, randomized comparison of 3 types of proximal interphalangeal joint arthroplastyThe journal of hand surgery. [American volume]","type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"320626709","language":["eng"],"pubHistory":["1.1976 -"],"titleAlt":[{"title":"The journal of hand surgery / American volume"},{"title":"A"},{"title":"American volume"}],"part":{"year":"2012","issue":"9","pages":"1770-1779.e3","volume":"37","text":"37(2012), 9, Seite 1770-1779.e3","extent":"10"}}],"physDesc":[{"extent":"10 S."}]} 
SRT |a DAECKEWOLFPROSPECTIV2020