Improved image quality with simultaneously reduced radiation exposure: Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting
BACKGROUND: The aim of this study was to assess the potential for radiation dose reduction using knowledge-based iterative model reconstruction (K-IMR) algorithms in combination with ultra-low dose body mass index (BMI)-adapted protocols in coronary CT angiography (coronary CTA). METHODS: Forty pati...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
23 February 2017
|
| In: |
Journal of cardiovascular computed tomography
Year: 2017, Jahrgang: 11, Heft: 3, Pages: 213-220 |
| ISSN: | 1876-861X |
| DOI: | 10.1016/j.jcct.2017.02.007 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1016/j.jcct.2017.02.007 |
| Verfasserangaben: | Florian André, Philipp Fortner, Mani Vembar, Dirk Mueller, Wolfram Stiller, Sebastian J. Buss, Hans-Ulrich Kauczor, Hugo A. Katus, Grigorios Korosoglou |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1575941414 | ||
| 003 | DE-627 | ||
| 005 | 20240316100356.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180604s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jcct.2017.02.007 |2 doi | |
| 035 | |a (DE-627)1575941414 | ||
| 035 | |a (DE-576)505941414 | ||
| 035 | |a (DE-599)BSZ505941414 | ||
| 035 | |a (OCoLC)1341010351 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a André, Florian |d 1983- |e VerfasserIn |0 (DE-588)1051060230 |0 (DE-627)785671714 |0 (DE-576)405733267 |4 aut | |
| 245 | 1 | 0 | |a Improved image quality with simultaneously reduced radiation exposure |b Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting |c Florian André, Philipp Fortner, Mani Vembar, Dirk Mueller, Wolfram Stiller, Sebastian J. Buss, Hans-Ulrich Kauczor, Hugo A. Katus, Grigorios Korosoglou |
| 264 | 1 | |c 23 February 2017 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 04.06.2018 | ||
| 520 | |a BACKGROUND: The aim of this study was to assess the potential for radiation dose reduction using knowledge-based iterative model reconstruction (K-IMR) algorithms in combination with ultra-low dose body mass index (BMI)-adapted protocols in coronary CT angiography (coronary CTA). METHODS: Forty patients undergoing clinically indicated coronary CTA were randomly assigned to two groups with BMI-adapted (I: <25.0 kg/m2, II: <28.0 kg/m2, III: <30.0 kg/m2, IV: ≥30.0 kg/m2) low dose (LD, I: 100kVp/75 mAs, II: 100kVp/100 mAs, III: 100kVp/150 mAs, IV: 120kVp/150 mAs, n = 20) or ultra-low dose (ULD, I: 100kVp/50 mAs, II: 100kVp/75 mAs, III: 100kVp/100 mAs, IV: 120kVp/100 mAs, n = 20) protocols. Prospectively-triggered coronary CTA was performed using a 256-MDCT with the lowest reasonable scan length. Images were generated with filtered back projection (FBP), a noise-reducing hybrid iterative algorithm (iD, levels 2/5) and K-IMR using cardiac routine (CR) and cardiac sharp settings, levels 1-3. RESULTS: Groups were comparable regarding anthropometric parameters, heart rate, and scan length. The use of ULD protocols resulted in a significant reduction of radiation exposure (0.7 (0.6-0.9) mSv vs. 1.1 (0.9-1.7) mSv; p < 0.02). Image quality was significantly better in the ULD group using K-IMR CR 1 compared to FBP, iD 2 and iD 5 in the LD group, resulting in fewer non-diagnostic coronary segments (2.4% vs. 11.6%, 9.2% and 6.1%; p < 0.05). CONCLUSIONS: The combination of K-IMR with BMI-adapted ULD protocols results in significant radiation dose savings while simultaneously improving image quality compared to LD protocols with FBP or hybrid iterative algorithms. Therefore, K-IMR allows for coronary CTA examinations with high diagnostic value and very low radiation exposure in clinical routine. | ||
| 650 | 4 | |a Aged | |
| 650 | 4 | |a Body Mass Index | |
| 650 | 4 | |a Computed Tomography Angiography | |
| 650 | 4 | |a Coronary Angiography | |
| 650 | 4 | |a Coronary artery disease | |
| 650 | 4 | |a Coronary CT angiography | |
| 650 | 4 | |a Coronary Vessels | |
| 650 | 4 | |a Female | |
| 650 | 4 | |a Humans | |
| 650 | 4 | |a Image reconstruction | |
| 650 | 4 | |a Iterative reconstruction | |
| 650 | 4 | |a Knowledge Bases | |
| 650 | 4 | |a Knowledge-based reconstruction | |
| 650 | 4 | |a Male | |
| 650 | 4 | |a Middle Aged | |
| 650 | 4 | |a Multidetector computed tomography | |
| 650 | 4 | |a Radiation Dosage | |
| 650 | 4 | |a Radiation exposure | |
| 650 | 4 | |a Radiographic Image Interpretation, Computer-Assisted | |
| 650 | 4 | |a Signal-To-Noise Ratio | |
| 700 | 1 | |a Fortner, Philipp |e VerfasserIn |0 (DE-588)1075389771 |0 (DE-627)833260456 |0 (DE-576)443459029 |4 aut | |
| 700 | 1 | |a Stiller, Wolfram |d 1976- |e VerfasserIn |0 (DE-588)105822672X |0 (DE-627)796627495 |0 (DE-576)414249496 |4 aut | |
| 700 | 1 | |a Buß, Sebastian Johannes |d 1977- |e VerfasserIn |0 (DE-588)131490451 |0 (DE-627)509814050 |0 (DE-576)298541963 |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Katus, Hugo |d 1951- |e VerfasserIn |0 (DE-588)108916618 |0 (DE-627)577155040 |0 (DE-576)289625076 |4 aut | |
| 700 | 1 | |a Korosoglou, Grigorios |d 1976- |e VerfasserIn |0 (DE-588)12854225X |0 (DE-627)374709025 |0 (DE-576)297204912 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of cardiovascular computed tomography |d Amsterdam [u.a.] : Elsevier, 2007 |g 11(2017), 3, Seite 213-220 |h Online-Ressource |w (DE-627)557882567 |w (DE-600)2406791-X |w (DE-576)336961626 |x 1876-861X |7 nnas |a Improved image quality with simultaneously reduced radiation exposure Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting |
| 773 | 1 | 8 | |g volume:11 |g year:2017 |g number:3 |g pages:213-220 |g extent:8 |a Improved image quality with simultaneously reduced radiation exposure Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jcct.2017.02.007 |x Verlag |x Resolving-System |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180604 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 12854225X |a Korosoglou, Grigorios |m 12854225X:Korosoglou, Grigorios |d 50000 |e 50000PK12854225X |k 0/50000/ |p 9 |y j | ||
| 998 | |g 108916618 |a Katus, Hugo |m 108916618:Katus, Hugo |d 910000 |d 910100 |e 910000PK108916618 |e 910100PK108916618 |k 0/910000/ |k 1/910000/910100/ |p 8 | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 7 | ||
| 998 | |g 131490451 |a Buß, Sebastian Johannes |m 131490451:Buß, Sebastian Johannes |d 50000 |e 50000PB131490451 |k 0/50000/ |p 6 | ||
| 998 | |g 105822672X |a Stiller, Wolfram |m 105822672X:Stiller, Wolfram |d 910000 |d 911400 |e 910000PS105822672X |e 911400PS105822672X |k 0/910000/ |k 1/910000/911400/ |p 5 | ||
| 998 | |g 1075389771 |a Fortner, Philipp |m 1075389771:Fortner, Philipp |d 910000 |d 910100 |e 910000PF1075389771 |e 910100PF1075389771 |k 0/910000/ |k 1/910000/910100/ |p 2 | ||
| 998 | |g 1051060230 |a André, Florian |m 1051060230:André, Florian |d 910000 |d 910100 |e 910000PA1051060230 |e 910100PA1051060230 |k 0/910000/ |k 1/910000/910100/ |p 1 |x j | ||
| 999 | |a KXP-PPN1575941414 |e 3011440190 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"physDesc":[{"extent":"8 S."}],"recId":"1575941414","note":["Gesehen am 04.06.2018"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"title":[{"title":"Improved image quality with simultaneously reduced radiation exposure","title_sort":"Improved image quality with simultaneously reduced radiation exposure","subtitle":"Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting"}],"person":[{"display":"André, Florian","family":"André","role":"aut","given":"Florian"},{"display":"Fortner, Philipp","given":"Philipp","role":"aut","family":"Fortner"},{"display":"Stiller, Wolfram","given":"Wolfram","role":"aut","family":"Stiller"},{"family":"Buß","given":"Sebastian Johannes","role":"aut","display":"Buß, Sebastian Johannes"},{"display":"Kauczor, Hans-Ulrich","role":"aut","given":"Hans-Ulrich","family":"Kauczor"},{"role":"aut","given":"Hugo","family":"Katus","display":"Katus, Hugo"},{"given":"Grigorios","role":"aut","family":"Korosoglou","display":"Korosoglou, Grigorios"}],"relHost":[{"recId":"557882567","physDesc":[{"extent":"Online-Ressource"}],"disp":"Improved image quality with simultaneously reduced radiation exposure Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical settingJournal of cardiovascular computed tomography","pubHistory":["1.2007 -"],"origin":[{"publisher":"Elsevier","dateIssuedKey":"2007","publisherPlace":"Amsterdam [u.a.]","dateIssuedDisp":"2007-"}],"part":{"extent":"8","text":"11(2017), 3, Seite 213-220","issue":"3","pages":"213-220","volume":"11","year":"2017"},"title":[{"title_sort":"Journal of cardiovascular computed tomography","title":"Journal of cardiovascular computed tomography","subtitle":"official journal of the Society of Cardiovascular Computed Tomography"}],"id":{"eki":["557882567"],"issn":["1876-861X"],"zdb":["2406791-X"]},"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"]}],"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"23 February 2017"}],"id":{"doi":["10.1016/j.jcct.2017.02.007"],"eki":["1575941414"]},"name":{"displayForm":["Florian André, Philipp Fortner, Mani Vembar, Dirk Mueller, Wolfram Stiller, Sebastian J. Buss, Hans-Ulrich Kauczor, Hugo A. Katus, Grigorios Korosoglou"]}} | ||
| SRT | |a ANDREFLORIIMPROVEDIM2320 | ||