Survival and chipping of zirconia-based and metal-ceramic implant-supported single crowns

Purpose: The objective of this retrospective study was to compare the incidence of chipping of implant-supported, all-ceramic, and metal-ceramic single crowns. Material and Methods: One hundred fifty-three patients (51.7% male, mean age 55.0 years) received 232 cemented implant-supported single crow...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kappel, Stefanie (VerfasserIn) , Schröder, Christin (VerfasserIn) , Hassel, Alexander J. (VerfasserIn) , Bömicke, Wolfgang (VerfasserIn) , Rammelsberg, Peter (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: May 2012
In: Clinical implant dentistry and related research
Year: 2011, Jahrgang: 14, Pages: e119-e125
ISSN:1708-8208
DOI:10.1111/j.1708-8208.2011.00388.x
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1111/j.1708-8208.2011.00388.x
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1708-8208.2011.00388.x
Volltext
Verfasserangaben:Stefanie Schwarz, Dr. med. dent., Christin Schröder, Alexander Hassel, Prof. Dr. med. dent., Wolfgang Bömicke, Dr. med. dent.,Peter Rammelsberg, Prof. Dr. med. dent.

MARC

LEADER 00000caa a2200000 c 4500
001 1575986523
003 DE-627
005 20220814153216.0
007 cr uuu---uuuuu
008 180605r20122011xx |||||o 00| ||eng c
024 7 |a 10.1111/j.1708-8208.2011.00388.x  |2 doi 
035 |a (DE-627)1575986523 
035 |a (DE-576)505986523 
035 |a (DE-599)BSZ505986523 
035 |a (OCoLC)1341010555 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Kappel, Stefanie  |d 1980-  |e VerfasserIn  |0 (DE-588)13162590X  |0 (DE-627)707687101  |0 (DE-576)298633876  |4 aut 
245 1 0 |a Survival and chipping of zirconia-based and metal-ceramic implant-supported single crowns  |c Stefanie Schwarz, Dr. med. dent., Christin Schröder, Alexander Hassel, Prof. Dr. med. dent., Wolfgang Bömicke, Dr. med. dent.,Peter Rammelsberg, Prof. Dr. med. dent. 
264 1 |c May 2012 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published: 10 October 2011 
500 |a Gesehen am 05.06.2018 
520 |a Purpose: The objective of this retrospective study was to compare the incidence of chipping of implant-supported, all-ceramic, and metal-ceramic single crowns. Material and Methods: One hundred fifty-three patients (51.7% male, mean age 55.0 years) received 232 cemented implant-supported single crowns. One hundred and seventy-nine crowns had a metal framework (gold alloy) and 53 crowns were all-ceramic (zirconia framework and glass-ceramic veneer material). Age, gender, kind of cementation, and location of the restorations were assessed as possible factors affecting chipping. Results: During the observation period of up to 5.8 years (mean 2.1 years; standard deviation 1.4), a total of 13 (24.5%) all-ceramic and 17 (9.5%) metal-ceramic crowns suffered from chipping, a difference that was statistically significant. A total of ten single crowns had to be remade resulting in survival of 86.8% (all-ceramic) and 98.3% (metal-ceramic). The other possible factors did not have a significant effect on the chipping. Conclusion: Chipping was found to be more frequent for all-ceramic implant-supported single crowns. If the reasons for the vulnerability of all-ceramic crowns remain unknown, implants with all-ceramic single crowns should generally be recommended with care. 
534 |c 2011 
650 4 |a all-ceramic 
650 4 |a chipping 
650 4 |a implants 
650 4 |a metal-ceramic 
650 4 |a single crowns 
650 4 |a survival 
700 1 |a Schröder, Christin  |d 1982-  |e VerfasserIn  |0 (DE-588)1020768002  |0 (DE-627)691340323  |0 (DE-576)357989643  |4 aut 
700 1 |a Hassel, Alexander J.  |d 1974-  |e VerfasserIn  |0 (DE-588)123724902  |0 (DE-627)706407903  |0 (DE-576)293846308  |4 aut 
700 1 |a Bömicke, Wolfgang  |d 1981-  |e VerfasserIn  |0 (DE-588)1015022146  |0 (DE-627)668338792  |0 (DE-576)349947651  |4 aut 
700 1 |a Rammelsberg, Peter  |d 1959-  |e VerfasserIn  |0 (DE-588)122469836  |0 (DE-627)705920836  |0 (DE-576)293285640  |4 aut 
773 0 8 |i Enthalten in  |t Clinical implant dentistry and related research  |d Oxford [u.a.] : Wiley-Blackwell, 1999  |g 14(2012), s1, Seite e119-e125  |h Online-Ressource  |w (DE-627)357167899  |w (DE-600)2094120-1  |w (DE-576)116598719  |x 1708-8208  |7 nnas  |a Survival and chipping of zirconia-based and metal-ceramic implant-supported single crowns 
773 1 8 |g volume:14  |g year:2012  |g supplement:s1  |g pages:e119-e125  |g extent:7  |a Survival and chipping of zirconia-based and metal-ceramic implant-supported single crowns 
856 4 0 |u http://dx.doi.org/10.1111/j.1708-8208.2011.00388.x  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1708-8208.2011.00388.x  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180605 
993 |a Article 
994 |a 2012 
998 |g 122469836  |a Rammelsberg, Peter  |m 122469836:Rammelsberg, Peter  |d 910000  |d 910800  |e 910000PR122469836  |e 910800PR122469836  |k 0/910000/  |k 1/910000/910800/  |p 5  |y j 
998 |g 1015022146  |a Bömicke, Wolfgang  |m 1015022146:Bömicke, Wolfgang  |d 910000  |d 910800  |e 910000PB1015022146  |e 910800PB1015022146  |k 0/910000/  |k 1/910000/910800/  |p 4 
998 |g 123724902  |a Hassel, Alexander J.  |m 123724902:Hassel, Alexander J.  |d 50000  |e 50000PH123724902  |k 0/50000/  |p 3 
998 |g 1020768002  |a Schröder, Christin  |m 1020768002:Schröder, Christin  |d 910000  |d 910800  |e 910000PS1020768002  |e 910800PS1020768002  |k 0/910000/  |k 1/910000/910800/  |p 2 
998 |g 13162590X  |a Kappel, Stefanie  |m 13162590X:Kappel, Stefanie  |d 910000  |d 910800  |e 910000PK13162590X  |e 910800PK13162590X  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1575986523  |e 301151397X 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Stefanie Schwarz, Dr. med. dent., Christin Schröder, Alexander Hassel, Prof. Dr. med. dent., Wolfgang Bömicke, Dr. med. dent.,Peter Rammelsberg, Prof. Dr. med. dent."]},"note":["First published: 10 October 2011","Gesehen am 05.06.2018"],"recId":"1575986523","title":[{"title_sort":"Survival and chipping of zirconia-based and metal-ceramic implant-supported single crowns","title":"Survival and chipping of zirconia-based and metal-ceramic implant-supported single crowns"}],"person":[{"family":"Kappel","display":"Kappel, Stefanie","given":"Stefanie","role":"aut"},{"display":"Schröder, Christin","family":"Schröder","given":"Christin","role":"aut"},{"given":"Alexander J.","family":"Hassel","display":"Hassel, Alexander J.","role":"aut"},{"role":"aut","family":"Bömicke","display":"Bömicke, Wolfgang","given":"Wolfgang"},{"display":"Rammelsberg, Peter","family":"Rammelsberg","given":"Peter","role":"aut"}],"physDesc":[{"extent":"7 S."}],"relHost":[{"id":{"doi":["10.1111/(ISSN)1708-8208"],"eki":["357167899"],"issn":["1708-8208"],"zdb":["2094120-1"]},"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"1999-","publisherPlace":"Oxford [u.a.] ; Hamilton, Ont.","dateIssuedKey":"1999","publisher":"Wiley-Blackwell ; B.C. Decker"}],"part":{"year":"2012","extent":"7","volume":"14","pages":"e119-e125","text":"14(2012), s1, Seite e119-e125"},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Clinical implant dentistry and related research","title":"Clinical implant dentistry and related research","subtitle":"CIDRR"}],"titleAlt":[{"title":"CIDRR"}],"disp":"Survival and chipping of zirconia-based and metal-ceramic implant-supported single crownsClinical implant dentistry and related research","recId":"357167899","pubHistory":["1.1999 -"]}],"origin":[{"dateIssuedDisp":"May 2012","dateIssuedKey":"2012"}],"id":{"eki":["1575986523"],"doi":["10.1111/j.1708-8208.2011.00388.x"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"]} 
SRT |a KAPPELSTEFSURVIVALAN2012