Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses: effect of span length and preparation design
Objectives: Evaluation of the effect of different span length and preparation designs on the fracture load of tooth-implant-supported fixed dental prostheses (TIFDPs) manufactured from yttrium-stabilized zirconia frameworks. Material and methods: Forty-eight TIFDPs were manufactured using a CAD/CAM...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
2012
|
| In: |
Clinical oral implants research
Year: 2011, Volume: 23, Issue: 6, Pages: 719-725 |
| ISSN: | 1600-0501 |
| DOI: | 10.1111/j.1600-0501.2011.02191.x |
| Online Access: | Verlag, Volltext: http://dx.doi.org/10.1111/j.1600-0501.2011.02191.x Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1600-0501.2011.02191.x |
| Author Notes: | Olaf Gabbert, Efstathios Karatzogiannis, Brigitte Ohlmann, Marc Schmitter, Jochen Karl, Peter Rammelsberg |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1575993775 | ||
| 003 | DE-627 | ||
| 005 | 20220814153326.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180605r20122011xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1111/j.1600-0501.2011.02191.x |2 doi | |
| 035 | |a (DE-627)1575993775 | ||
| 035 | |a (DE-576)505993775 | ||
| 035 | |a (DE-599)BSZ505993775 | ||
| 035 | |a (OCoLC)1341010626 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Gabbert, Olaf |d 1966- |e VerfasserIn |0 (DE-588)133292517 |0 (DE-627)539938289 |0 (DE-576)29975314X |4 aut | |
| 245 | 1 | 0 | |a Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses |b effect of span length and preparation design |c Olaf Gabbert, Efstathios Karatzogiannis, Brigitte Ohlmann, Marc Schmitter, Jochen Karl, Peter Rammelsberg |
| 264 | 1 | |c 2012 | |
| 300 | |a 7 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a First published: 03 August 2011 | ||
| 500 | |a Gesehen am 05.06.2018 | ||
| 520 | |a Objectives: Evaluation of the effect of different span length and preparation designs on the fracture load of tooth-implant-supported fixed dental prostheses (TIFDPs) manufactured from yttrium-stabilized zirconia frameworks. Material and methods: Forty-eight TIFDPs were manufactured using a CAD/CAM system and veneered with a press ceramic. Rigidly mounted implants (SLA, diameter 4.1 mm, length 10 mm) in the molar region with a titanium abutment were embedded in PMMA bases pairwise with premolars. All premolars were covered with heat-shrink tubing to simulate physiological tooth mobility. Six different test groups were prepared (a) differing in the preparation design of the premolar (inlay [i]; crown [c]), (b) the material of the premolar (metal [m]; natural human [h]) and (c) the length of the TIFDPs (3-unit [3]; 4-unit [4]). All TIFDPs underwent thermomechanical loading (TCML) (10,000 × 6.5°/60°; 6 × 105× 50 N). The load to fracture (N) was measured and fracture sites were evaluated macroscopically. Results: None of the restorations failed during TCML. The mean fracture loads (standard deviations) were 1,522 N (249) for the 3-unit, inlay-retained TIFDPs on a metal abutment tooth (3-im), 1,910 N (165) for the 3-cm group, 1,049 N (183) for group 4-im, 1,274 N (282) for group 4-cm, 1,229 N (174) for group 4-ih and 911 N (205) for group 4-ch. Initial damages within the veneering ceramic occurred before the final failure of the restoration. The corresponding loads were 24-52% lower than the fracture load values. Conclusions: All restorations tested could withstand the mastication forces expected. Fracture-load values for 3- and 4-unit inlay-crown and crown-crown-retained TIFDPs should spur further clinical investigation. | ||
| 534 | |c 2011 | ||
| 650 | 4 | |a all-ceramic suprastructures | |
| 650 | 4 | |a combined tooth-implant-supported FDPs | |
| 650 | 4 | |a dental implants | |
| 650 | 4 | |a fixed dental prostheses | |
| 650 | 4 | |a in vitro | |
| 650 | 4 | |a rigid and non-rigid connection | |
| 650 | 4 | |a splinting | |
| 650 | 4 | |a tooth-implant connection | |
| 650 | 4 | |a zirconia ceramic | |
| 700 | 1 | |a Karatzogiannis, Efstathios |d 1981- |e VerfasserIn |0 (DE-588)1015021581 |0 (DE-627)705318907 |0 (DE-576)349873658 |4 aut | |
| 700 | 1 | |a Ohlmann, Brigitte |d 1972- |e VerfasserIn |0 (DE-588)121937925 |0 (DE-627)705708691 |0 (DE-576)31798750X |4 aut | |
| 700 | 1 | |a Schmitter, Marc |d 1970- |e VerfasserIn |0 (DE-588)12087024X |0 (DE-627)705051471 |0 (DE-576)180188836 |4 aut | |
| 700 | 1 | |a Karl, Jochen |e VerfasserIn |0 (DE-588)1160551138 |0 (DE-627)1023822547 |0 (DE-576)505994399 |4 aut | |
| 700 | 1 | |a Rammelsberg, Peter |d 1959- |e VerfasserIn |0 (DE-588)122469836 |0 (DE-627)705920836 |0 (DE-576)293285640 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Clinical oral implants research |d Oxford : Wiley-Blackwell, 1990 |g 23(2012), 6, Seite 719-725 |h Online-Ressource |w (DE-627)324484526 |w (DE-600)2027104-9 |w (DE-576)09388883X |x 1600-0501 |7 nnas |a Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses effect of span length and preparation design |
| 773 | 1 | 8 | |g volume:23 |g year:2012 |g number:6 |g pages:719-725 |g extent:7 |a Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses effect of span length and preparation design |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1111/j.1600-0501.2011.02191.x |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1600-0501.2011.02191.x |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180605 | ||
| 993 | |a Article | ||
| 994 | |a 2012 | ||
| 998 | |g 122469836 |a Rammelsberg, Peter |m 122469836:Rammelsberg, Peter |d 910000 |d 910800 |e 910000PR122469836 |e 910800PR122469836 |k 0/910000/ |k 1/910000/910800/ |p 6 |y j | ||
| 998 | |g 1160551138 |a Jochen, Karl |m 1160551138:Jochen, Karl |d 910000 |d 910800 |e 910000PJ1160551138 |e 910800PJ1160551138 |k 0/910000/ |k 1/910000/910800/ |p 5 | ||
| 998 | |g 12087024X |a Schmitter, Marc |m 12087024X:Schmitter, Marc |d 910000 |d 910800 |e 910000PS12087024X |e 910800PS12087024X |k 0/910000/ |k 1/910000/910800/ |p 4 | ||
| 998 | |g 121937925 |a Ohlmann, Brigitte |m 121937925:Ohlmann, Brigitte |d 910000 |d 910800 |e 910000PO121937925 |e 910800PO121937925 |k 0/910000/ |k 1/910000/910800/ |p 3 | ||
| 998 | |g 1015021581 |a Karatzogiannis, Efstathios |m 1015021581:Karatzogiannis, Efstathios |d 910000 |d 910800 |e 910000PK1015021581 |e 910800PK1015021581 |k 0/910000/ |k 1/910000/910800/ |p 2 | ||
| 998 | |g 133292517 |a Gabbert, Olaf |m 133292517:Gabbert, Olaf |d 910000 |d 910800 |e 910000PG133292517 |e 910800PG133292517 |k 0/910000/ |k 1/910000/910800/ |p 1 |x j | ||
| 999 | |a KXP-PPN1575993775 |e 3011524416 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"language":["eng"],"id":{"eki":["1575993775"],"doi":["10.1111/j.1600-0501.2011.02191.x"]},"type":{"media":"Online-Ressource","bibl":"article-journal"},"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"2012"}],"relHost":[{"recId":"324484526","pubHistory":["1.1990 -"],"note":["Gesehen am 28.03.2022"],"disp":"Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses effect of span length and preparation designClinical oral implants research","part":{"text":"23(2012), 6, Seite 719-725","pages":"719-725","volume":"23","issue":"6","extent":"7","year":"2012"},"title":[{"title_sort":"Clinical oral implants research","subtitle":"official publication of the European Association for Osseointegration","title":"Clinical oral implants research"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"issn":["1600-0501"],"zdb":["2027104-9"],"doi":["10.1111/(ISSN)1600-0501"],"eki":["324484526"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"origin":[{"dateIssuedKey":"1990","publisher":"Wiley-Blackwell ; Munksgaard ; Blackwell","publisherPlace":"Oxford ; Copenhagen ; Oxford [u.a.]","dateIssuedDisp":"1990-"}]}],"person":[{"given":"Olaf","display":"Gabbert, Olaf","family":"Gabbert","role":"aut"},{"role":"aut","display":"Karatzogiannis, Efstathios","family":"Karatzogiannis","given":"Efstathios"},{"family":"Ohlmann","display":"Ohlmann, Brigitte","given":"Brigitte","role":"aut"},{"role":"aut","given":"Marc","family":"Schmitter","display":"Schmitter, Marc"},{"given":"Jochen","family":"Karl","display":"Karl, Jochen","role":"aut"},{"display":"Rammelsberg, Peter","family":"Rammelsberg","given":"Peter","role":"aut"}],"title":[{"subtitle":"effect of span length and preparation design","title":"Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses","title_sort":"Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses"}],"physDesc":[{"extent":"7 S."}],"recId":"1575993775","note":["First published: 03 August 2011","Gesehen am 05.06.2018"],"name":{"displayForm":["Olaf Gabbert, Efstathios Karatzogiannis, Brigitte Ohlmann, Marc Schmitter, Jochen Karl, Peter Rammelsberg"]}} | ||
| SRT | |a GABBERTOLAFRACTURELO2012 | ||