Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization

The objective of this paper is to evaluate an iterative maximum likelihood (ML) cone-beam computed tomography (CBCT) reconstruction with total variation (TV) regularization with respect to the robustness of the algorithm due to data inconsistencies. Three different and (for clinical application) typ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Stsepankou, Dzmitry (VerfasserIn) , Arns, Anna Maria (VerfasserIn) , Hesser, Jürgen (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 11 September 2012
In: Physics in medicine and biology
Year: 2012, Jahrgang: 57, Heft: 19, Pages: 5955-5970
ISSN:1361-6560
DOI:10.1088/0031-9155/57/19/5955
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1088/0031-9155/57/19/5955
Verlag, Volltext: http://stacks.iop.org/0031-9155/57/i=19/a=5955
Volltext
Verfasserangaben:D Stsepankou, A Arns, S K Ng, P Zygmanski and J Hesser

MARC

LEADER 00000caa a2200000 c 4500
001 1576216152
003 DE-627
005 20220814160316.0
007 cr uuu---uuuuu
008 180611s2012 xx |||||o 00| ||eng c
024 7 |a 10.1088/0031-9155/57/19/5955  |2 doi 
035 |a (DE-627)1576216152 
035 |a (DE-576)506216152 
035 |a (DE-599)BSZ506216152 
035 |a (OCoLC)1341011223 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Stsepankou, Dzmitry  |d 1976-  |e VerfasserIn  |0 (DE-588)1020647663  |0 (DE-627)69129125X  |0 (DE-576)361517831  |4 aut 
245 1 0 |a Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization  |c D Stsepankou, A Arns, S K Ng, P Zygmanski and J Hesser 
264 1 |c 11 September 2012 
300 |a 16 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 20.08.2020 
520 |a The objective of this paper is to evaluate an iterative maximum likelihood (ML) cone-beam computed tomography (CBCT) reconstruction with total variation (TV) regularization with respect to the robustness of the algorithm due to data inconsistencies. Three different and (for clinical application) typical classes of errors are considered for simulated phantom and measured projection data: quantum noise, defect detector pixels and projection matrix errors. To quantify those errors we apply error measures like mean square error, signal-to-noise ratio, contrast-to-noise ratio and streak indicator. These measures are derived from linear signal theory and generalized and applied for nonlinear signal reconstruction. For quality check, we focus on resolution and CT-number linearity based on a Catphan phantom. All comparisons are made versus the clinical standard, the filtered backprojection algorithm (FBP). In our results, we confirm and substantially extend previous results on iterative reconstruction such as massive undersampling of the number of projections. Errors of projection matrix parameters of up to 1° projection angle deviations are still in the tolerance level. Single defect pixels exhibit ring artifacts for each method. However using defect pixel compensation, allows up to 40% of defect pixels for passing the standard clinical quality check. Further, the iterative algorithm is extraordinarily robust in the low photon regime (down to 0.05 mAs) when compared to FPB, allowing for extremely low-dose image acquisitions, a substantial issue when considering daily CBCT imaging for position correction in radiotherapy. We conclude that the ML method studied herein is robust under clinical quality assurance conditions. Consequently, low-dose regime imaging, especially for daily patient localization in radiation therapy is possible without change of the current hardware of the imaging system. 
700 1 |a Arns, Anna Maria  |d 1984-  |e VerfasserIn  |0 (DE-588)1119363764  |0 (DE-627)872713377  |0 (DE-576)314141677  |4 aut 
700 1 |a Hesser, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1020647353  |0 (DE-627)691291071  |0 (DE-576)361513739  |4 aut 
773 0 8 |i Enthalten in  |t Physics in medicine and biology  |d Bristol : IOP Publ., 1956  |g 57(2012), 19, Seite 5955-5970  |h Online-Ressource  |w (DE-627)269016163  |w (DE-600)1473501-5  |w (DE-576)088704130  |x 1361-6560  |7 nnas  |a Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization 
773 1 8 |g volume:57  |g year:2012  |g number:19  |g pages:5955-5970  |g extent:16  |a Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization 
856 4 0 |u http://dx.doi.org/10.1088/0031-9155/57/19/5955  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://stacks.iop.org/0031-9155/57/i=19/a=5955  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180611 
993 |a Article 
994 |a 2012 
998 |g 1020647353  |a Hesser, Jürgen  |m 1020647353:Hesser, Jürgen  |d 60000  |d 63000  |e 60000PH1020647353  |e 63000PH1020647353  |k 0/60000/  |k 1/60000/63000/  |p 5  |y j 
998 |g 1119363764  |a Arns, Anna Maria  |m 1119363764:Arns, Anna Maria  |d 60000  |d 63000  |e 60000PA1119363764  |e 63000PA1119363764  |k 0/60000/  |k 1/60000/63000/  |p 2 
998 |g 1020647663  |a Stsepankou, Dzmitry  |m 1020647663:Stsepankou, Dzmitry  |d 60000  |d 63000  |e 60000PS1020647663  |e 63000PS1020647663  |k 0/60000/  |k 1/60000/63000/  |p 1  |x j 
999 |a KXP-PPN1576216152  |e 3012318534 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title_sort":"Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization","title":"Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization"}],"recId":"1576216152","origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"11 September 2012"}],"language":["eng"],"person":[{"roleDisplay":"VerfasserIn","display":"Stsepankou, Dzmitry","family":"Stsepankou","role":"aut","given":"Dzmitry"},{"display":"Arns, Anna Maria","family":"Arns","given":"Anna Maria","role":"aut","roleDisplay":"VerfasserIn"},{"roleDisplay":"VerfasserIn","display":"Hesser, Jürgen","family":"Hesser","given":"Jürgen","role":"aut"}],"name":{"displayForm":["D Stsepankou, A Arns, S K Ng, P Zygmanski and J Hesser"]},"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1576216152"],"doi":["10.1088/0031-9155/57/19/5955"]},"physDesc":[{"extent":"16 S."}],"note":["Gesehen am 20.08.2020"],"relHost":[{"recId":"269016163","disp":"Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularizationPhysics in medicine and biology","origin":[{"publisher":"IOP Publ.","publisherPlace":"Bristol","dateIssuedDisp":"1956-","dateIssuedKey":"1956"}],"language":["eng"],"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine","title":"Physics in medicine and biology","title_sort":"Physics in medicine and biology"}],"pubHistory":["1.1956 -"],"id":{"zdb":["1473501-5"],"eki":["269016163"],"issn":["1361-6560"]},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 28.01.2019","Fortsetzung der Druck-Ausgabe"],"part":{"text":"57(2012), 19, Seite 5955-5970","year":"2012","extent":"16","volume":"57","pages":"5955-5970","issue":"19"},"type":{"bibl":"periodical","media":"Online-Ressource"}}]} 
SRT |a STSEPANKOUEVALUATION1120