Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients

A majority of geriatric patients experience difficulty in performing sit-to-stand (SiSt) transitions. A detailed assessment of SiSt ability is a prerequisite for successful rehabilitation. Body fixed sensors (BFSs) are increasingly used to assess functional performances. As to date there is no syste...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schwenk, Michael (VerfasserIn) , Wiloth, Stefanie (VerfasserIn) , Englert, Stefan (VerfasserIn) , Czempik, Anna (VerfasserIn) , Hauer, Klaus (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 31 October 2012
In: Physiological measurement
Year: 2012, Jahrgang: 33, Heft: 11, Pages: 1931-1946
ISSN:1361-6579
DOI:10.1088/0967-3334/33/11/1931
Online-Zugang:Verlag, Volltext: http://dx.doi.org/10.1088/0967-3334/33/11/1931
Verlag, Volltext: http://stacks.iop.org/0967-3334/33/i=11/a=1931
Volltext
Verfasserangaben:M. Schwenk, S. Gogulla, S. Englert, A. Czempik, K. Hauer

MARC

LEADER 00000caa a2200000 c 4500
001 1576248917
003 DE-627
005 20220814160901.0
007 cr uuu---uuuuu
008 180611s2012 xx |||||o 00| ||eng c
024 7 |a 10.1088/0967-3334/33/11/1931  |2 doi 
035 |a (DE-627)1576248917 
035 |a (DE-576)506248917 
035 |a (DE-599)BSZ506248917 
035 |a (OCoLC)1341011273 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schwenk, Michael  |d 1979-  |e VerfasserIn  |0 (DE-588)101234472X  |0 (DE-627)704855224  |0 (DE-576)344891291  |4 aut 
245 1 0 |a Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients  |c M. Schwenk, S. Gogulla, S. Englert, A. Czempik, K. Hauer 
264 1 |c 31 October 2012 
300 |a 17 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 11.06.2018 
520 |a A majority of geriatric patients experience difficulty in performing sit-to-stand (SiSt) transitions. A detailed assessment of SiSt ability is a prerequisite for successful rehabilitation. Body fixed sensors (BFSs) are increasingly used to assess functional performances. As to date there is no system which analyzes clinically relevant phases of SiSt, the aim of this study was to determine the reliability of an automated approach for quantifying durations and angular velocities of trunk flexion and extension during repeated SiSt transitions using one BFS (DynaPort® Hybrid). Forty multimorbid geriatric patients aged 84.1 ± 6.6 years were included. Each patient participated in two test sessions with a 5 min rest period in between. Intra- and interrater reliability was assessed. Intraclass correlation coefficients (ICCs), absolute and relative standard measurement errors (SEMs, SEMs%) and minimal detectable changes (MDCs 95 , MDCs 95 %) were calculated. ICCs were good to excellent for all variables in the total sample (0.80-0.94). The intraobserver group (50%) showed a higher number of excellent ICCs (≥.9) compared to the interobserver subgroup (10%). SEM% was low for all variables (6.9-12.7%). MDC 95 % ranged 19.2-34.4% and more variables ≤30% were found in the intra- (80%) compared to the inter-observer group (60%). Study results demonstrate that the BFS system provides a reliable analysis of SiSt phases in geriatric patients, and is a substantial improvement over the stopwatch approach used in clinical practice today. 
700 1 |a Wiloth, Stefanie  |d 1985-  |e VerfasserIn  |0 (DE-588)1082151173  |0 (DE-627)847175782  |0 (DE-576)455146624  |4 aut 
700 1 |a Englert, Stefan  |d 1986-  |e VerfasserIn  |0 (DE-588)1037466241  |0 (DE-627)755789539  |0 (DE-576)391501917  |4 aut 
700 1 |a Czempik, Anna  |e VerfasserIn  |0 (DE-588)1160909989  |0 (DE-627)1024312348  |0 (DE-576)50624833X  |4 aut 
700 1 |a Hauer, Klaus  |d 1956-  |e VerfasserIn  |0 (DE-588)172602270  |0 (DE-627)697537048  |0 (DE-576)13346167X  |4 aut 
773 0 8 |i Enthalten in  |t Physiological measurement  |d Bristol : IOP Publ., 1993  |g 33(2012), 11, Seite 1931-1946  |h Online-Ressource  |w (DE-627)311994571  |w (DE-600)2002076-4  |w (DE-576)104194146  |x 1361-6579  |7 nnas  |a Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients 
773 1 8 |g volume:33  |g year:2012  |g number:11  |g pages:1931-1946  |g extent:17  |a Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients 
856 4 0 |u http://dx.doi.org/10.1088/0967-3334/33/11/1931  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u http://stacks.iop.org/0967-3334/33/i=11/a=1931  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180611 
993 |a Article 
994 |a 2012 
998 |g 172602270  |a Hauer, Klaus  |m 172602270:Hauer, Klaus  |d 50000  |e 50000PH172602270  |k 0/50000/  |p 5  |y j 
998 |g 1160909989  |a Czempik, Anna  |m 1160909989:Czempik, Anna  |d 850000  |d 851600  |e 850000PC1160909989  |e 851600PC1160909989  |k 0/850000/  |k 1/850000/851600/  |p 4 
998 |g 1037466241  |a Englert, Stefan  |m 1037466241:Englert, Stefan  |d 50000  |e 50000PE1037466241  |k 0/50000/  |p 3 
998 |g 1082151173  |a Wiloth, Stefanie  |m 1082151173:Wiloth, Stefanie  |p 2 
998 |g 101234472X  |a Schwenk, Michael  |m 101234472X:Schwenk, Michael  |d 850000  |d 851600  |e 850000PS101234472X  |e 851600PS101234472X  |k 0/850000/  |k 1/850000/851600/  |p 1  |x j 
999 |a KXP-PPN1576248917  |e 3012414797 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"name":{"displayForm":["M. Schwenk, S. Gogulla, S. Englert, A. Czempik, K. Hauer"]},"person":[{"family":"Schwenk","role":"aut","given":"Michael","display":"Schwenk, Michael"},{"family":"Wiloth","given":"Stefanie","display":"Wiloth, Stefanie","role":"aut"},{"family":"Englert","role":"aut","display":"Englert, Stefan","given":"Stefan"},{"family":"Czempik","role":"aut","given":"Anna","display":"Czempik, Anna"},{"display":"Hauer, Klaus","given":"Klaus","role":"aut","family":"Hauer"}],"title":[{"title":"Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients","title_sort":"Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients"}],"id":{"doi":["10.1088/0967-3334/33/11/1931"],"eki":["1576248917"]},"physDesc":[{"extent":"17 S."}],"origin":[{"dateIssuedKey":"2012","dateIssuedDisp":"31 October 2012"}],"note":["Gesehen am 11.06.2018"],"recId":"1576248917","relHost":[{"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patientsPhysiological measurement","physDesc":[{"extent":"Online-Ressource"}],"title":[{"subtitle":"an official journal of the Institute of Physics and Engineering in Medicine, representing also the Deutsche Gesellschaft für Medizinische Physik, the European Federation of Organisations for Medical Physics and the International Organization for Medical Physics","title":"Physiological measurement","title_sort":"Physiological measurement"}],"part":{"volume":"33","extent":"17","issue":"11","year":"2012","pages":"1931-1946","text":"33(2012), 11, Seite 1931-1946"},"pubHistory":["14 (1993)-"],"note":["Gesehen am 12.01.22","Fortsetzung der Druck-Ausgabe"],"origin":[{"dateIssuedDisp":"[1993]-","publisher":"IOP Publ.","publisherPlace":"Bristol"}],"recId":"311994571","language":["eng"],"id":{"issn":["1361-6579"],"doi":["10.1088/issn.0967-3334"],"eki":["311994571"],"zdb":["2002076-4"]}}]} 
SRT |a SCHWENKMICTESTRETEST3120