Precision of MRI/ultrasound-fusion biopsy in prostate cancer diagnosis: an ex vivo comparison of alternative biopsy techniques on prostate phantoms
Purpose: Comparing the accuracy of MRI/ultrasound-guided target-biopsy by transrectal biopsy (TRB) with elastic versus rigid image fusion versus transperineal biopsy (TPB) with rigid image fusion in a standardized setting. Methods: Target-biopsy of six differently sized and located lesions was perfo...
Gespeichert in:
| Hauptverfasser: | , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
2017
|
| In: |
World journal of urology
Year: 2017, Jahrgang: 35, Heft: 7, Pages: 1015-1022 |
| ISSN: | 1433-8726 |
| DOI: | 10.1007/s00345-016-1967-3 |
| Online-Zugang: | Verlag, Volltext: http://dx.doi.org/10.1007/s00345-016-1967-3 Verlag, Volltext: https://link-springer-com.ezproxy.medma.uni-heidelberg.de/article/10.1007/s00345-016-1967-3 |
| Verfasserangaben: | N. Westhoff, F.P. Siegel, D. Hausmann, M. Polednik, J. von Hardenberg, M.S. Michel, M. Ritter |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1576355780 | ||
| 003 | DE-627 | ||
| 005 | 20221020084440.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 180614s2017 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1007/s00345-016-1967-3 |2 doi | |
| 035 | |a (DE-627)1576355780 | ||
| 035 | |a (DE-576)506355780 | ||
| 035 | |a (DE-599)BSZ506355780 | ||
| 035 | |a (OCoLC)1341011717 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Westhoff, Niklas Christian |d 1988- |e VerfasserIn |0 (DE-588)107322306X |0 (DE-627)828672628 |0 (DE-576)434741752 |4 aut | |
| 245 | 1 | 0 | |a Precision of MRI/ultrasound-fusion biopsy in prostate cancer diagnosis |b an ex vivo comparison of alternative biopsy techniques on prostate phantoms |c N. Westhoff, F.P. Siegel, D. Hausmann, M. Polednik, J. von Hardenberg, M.S. Michel, M. Ritter |
| 264 | 1 | |c 2017 | |
| 300 | |a 8 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a First online: 09 November 2016 | ||
| 500 | |a Gesehen am 14.06.2018 | ||
| 520 | |a Purpose: Comparing the accuracy of MRI/ultrasound-guided target-biopsy by transrectal biopsy (TRB) with elastic versus rigid image fusion versus transperineal biopsy (TPB) with rigid image fusion in a standardized setting. Methods: Target-biopsy of six differently sized and located lesions was performed on customized CIRS 070L prostate phantoms. Lesions were only MRI-visible. After prior MRI for lesion location, one targeted biopsy per lesion was obtained by TRB with elastic image fusion with Artemis™ (Eigen, USA), TRB with rigid image fusion with real-time virtual sonography (Hitachi, Japan) and TPB with rigid image fusion with a brachytherapy approach (Elekta, Sweden), each on a phantom of 50, 100 and 150 ml prostate volume. The needle trajectories were marked by contrast agent and detected in a postinterventional MRI. Results: Overall target detection rate was 79.6% with a slight superiority for the TPB (83.3 vs. 77.8 vs. 77.8%). TRB with elastic image fusion showed the highest overall precision [median distance to lesion center 2.37 mm (0.14-4.18 mm)], independent of prostate volume. Anterior lesions were significantly more precisely hit than transitional and basal lesions (p = 0.034; p = 0.015) with comparable accuracy for TRB with elastic image fusion and TPB. In general, TRB with rigid image fusion was inferior [median 3.15 mm (0.37-10.62 mm)], particularly in small lesions. Conclusion: All biopsy techniques allow detection of clinically significant tumors with a median error of 2-3 mm. Elastic image fusion appears to be the most precise technique, independent of prostate volume, target size or location. | ||
| 700 | 1 | |a Siegel, Fabian |d 1979- |e VerfasserIn |0 (DE-588)1034567551 |0 (DE-627)745868037 |0 (DE-576)382210514 |4 aut | |
| 700 | 1 | |a Hausmann, Daniel |d 1981- |e VerfasserIn |0 (DE-588)1012080293 |0 (DE-627)660894432 |0 (DE-576)344897125 |4 aut | |
| 700 | 1 | |a Polednik, Martin |d 1972- |e VerfasserIn |0 (DE-588)14139028X |0 (DE-627)703967053 |0 (DE-576)323549853 |4 aut | |
| 700 | 1 | |a Hardenberg, Jost von |d 1982- |e VerfasserIn |0 (DE-588)1020494328 |0 (DE-627)688149278 |0 (DE-576)360578241 |4 aut | |
| 700 | 1 | |a Michel, Maurice Stephan |d 1970- |e VerfasserIn |0 (DE-588)121842568 |0 (DE-627)705674134 |0 (DE-576)29291363X |4 aut | |
| 700 | 1 | |a Ritter, Manuel |d 1979- |e VerfasserIn |0 (DE-588)1030329915 |0 (DE-627)73508436X |0 (DE-576)378128256 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t World journal of urology |d Berlin : Springer, 1983 |g 35(2017), 7, Seite 1015-1022 |h Online-Ressource |w (DE-627)254910874 |w (DE-600)1463303-6 |w (DE-576)074754505 |x 1433-8726 |7 nnas |a Precision of MRI/ultrasound-fusion biopsy in prostate cancer diagnosis an ex vivo comparison of alternative biopsy techniques on prostate phantoms |
| 773 | 1 | 8 | |g volume:35 |g year:2017 |g number:7 |g pages:1015-1022 |g extent:8 |a Precision of MRI/ultrasound-fusion biopsy in prostate cancer diagnosis an ex vivo comparison of alternative biopsy techniques on prostate phantoms |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00345-016-1967-3 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u https://link-springer-com.ezproxy.medma.uni-heidelberg.de/article/10.1007/s00345-016-1967-3 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20180614 | ||
| 993 | |a Article | ||
| 994 | |a 2017 | ||
| 998 | |g 1030329915 |a Ritter, Manuel |m 1030329915:Ritter, Manuel |d 60000 |d 63100 |e 60000PR1030329915 |e 63100PR1030329915 |k 0/60000/ |k 1/60000/63100/ |p 7 |y j | ||
| 998 | |g 121842568 |a Michel, Maurice Stephan |m 121842568:Michel, Maurice Stephan |d 60000 |d 63100 |e 60000PM121842568 |e 63100PM121842568 |k 0/60000/ |k 1/60000/63100/ |p 6 | ||
| 998 | |g 1020494328 |a Hardenberg, Jost von |m 1020494328:Hardenberg, Jost von |d 60000 |d 63100 |e 60000PH1020494328 |e 63100PH1020494328 |k 0/60000/ |k 1/60000/63100/ |p 5 | ||
| 998 | |g 14139028X |a Polednik, Martin |m 14139028X:Polednik, Martin |d 60000 |d 63000 |e 60000PP14139028X |e 63000PP14139028X |k 0/60000/ |k 1/60000/63000/ |p 4 | ||
| 998 | |g 1012080293 |a Hausmann, Daniel |m 1012080293:Hausmann, Daniel |d 60000 |e 60000PH1012080293 |k 0/60000/ |p 3 | ||
| 998 | |g 1034567551 |a Siegel, Fabian |m 1034567551:Siegel, Fabian |d 60000 |d 63100 |e 60000PS1034567551 |e 63100PS1034567551 |k 0/60000/ |k 1/60000/63100/ |p 2 | ||
| 998 | |g 107322306X |a Westhoff, Niklas Christian |m 107322306X:Westhoff, Niklas Christian |d 60000 |d 63100 |e 60000PW107322306X |e 63100PW107322306X |k 0/60000/ |k 1/60000/63100/ |p 1 |x j | ||
| 999 | |a KXP-PPN1576355780 |e 3012662774 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"title":[{"subtitle":"an ex vivo comparison of alternative biopsy techniques on prostate phantoms","title":"Precision of MRI/ultrasound-fusion biopsy in prostate cancer diagnosis","title_sort":"Precision of MRI/ultrasound-fusion biopsy in prostate cancer diagnosis"}],"language":["eng"],"recId":"1576355780","origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"2017"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"doi":["10.1007/s00345-016-1967-3"],"eki":["1576355780"]},"physDesc":[{"extent":"8 S."}],"relHost":[{"language":["eng"],"part":{"volume":"35","text":"35(2017), 7, Seite 1015-1022","year":"2017","pages":"1015-1022","extent":"8","issue":"7"},"title":[{"title_sort":"World journal of urology","title":"World journal of urology"}],"pubHistory":["1.1983 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"origin":[{"publisherPlace":"Berlin ; Heidelberg","dateIssuedDisp":"1983-","publisher":"Springer","dateIssuedKey":"1983"}],"recId":"254910874","note":["Gesehen am 06.12.05","Teils ungezählte Beil.: Supplement"],"disp":"Precision of MRI/ultrasound-fusion biopsy in prostate cancer diagnosis an ex vivo comparison of alternative biopsy techniques on prostate phantomsWorld journal of urology","id":{"eki":["254910874"],"zdb":["1463303-6"],"issn":["1433-8726"]},"physDesc":[{"extent":"Online-Ressource"}]}],"note":["First online: 09 November 2016","Gesehen am 14.06.2018"],"name":{"displayForm":["N. Westhoff, F.P. Siegel, D. Hausmann, M. Polednik, J. von Hardenberg, M.S. Michel, M. Ritter"]},"person":[{"family":"Westhoff","role":"aut","given":"Niklas Christian","display":"Westhoff, Niklas Christian"},{"given":"Fabian","role":"aut","display":"Siegel, Fabian","family":"Siegel"},{"family":"Hausmann","display":"Hausmann, Daniel","role":"aut","given":"Daniel"},{"family":"Polednik","display":"Polednik, Martin","given":"Martin","role":"aut"},{"display":"Hardenberg, Jost von","role":"aut","given":"Jost von","family":"Hardenberg"},{"role":"aut","given":"Maurice Stephan","display":"Michel, Maurice Stephan","family":"Michel"},{"family":"Ritter","display":"Ritter, Manuel","given":"Manuel","role":"aut"}]} | ||
| SRT | |a WESTHOFFNIPRECISIONO2017 | ||