High early post-operative complication rate after elective aseptic orthopedic implant removal of upper and lower limb

The necessity of orthopedic implant removal is under intense discussion and even if it is performed as an elective procedure, the risk of complications is present. Aim of the study was to identify parameters responsible for an increased risk of early post-operative complications after elective asept...

Full description

Saved in:
Bibliographic Details
Main Authors: Höppchen, Arnold (Author) , Heilgeist, Eva (Author) , Tinelli, Marco (Author) , Bischel, Oliver E. (Author)
Format: Article (Journal)
Language:English
Published: 2018
In: Journal of orthopaedic research
Year: 2017, Volume: 36, Issue: 3, Pages: 1035-1039
ISSN:1554-527X
DOI:10.1002/jor.23718
Online Access:Verlag, Volltext: http://dx.doi.org/10.1002/jor.23718
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jor.23718
Get full text
Author Notes:Arnold J. Suda, Eva Heilgeist, Marco Tinelli, Oliver E. Bischel

MARC

LEADER 00000caa a2200000 c 4500
001 157637761X
003 DE-627
005 20220814163712.0
007 cr uuu---uuuuu
008 180614r20182017xx |||||o 00| ||eng c
024 7 |a 10.1002/jor.23718  |2 doi 
035 |a (DE-627)157637761X 
035 |a (DE-576)50637761X 
035 |a (DE-599)BSZ50637761X 
035 |a (OCoLC)1341011594 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Höppchen, Arnold  |d 1978-  |e VerfasserIn  |0 (DE-588)1075748429  |0 (DE-627)833789589  |0 (DE-576)444622861  |4 aut 
245 1 0 |a High early post-operative complication rate after elective aseptic orthopedic implant removal of upper and lower limb  |c Arnold J. Suda, Eva Heilgeist, Marco Tinelli, Oliver E. Bischel 
264 1 |c 2018 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online 1 September 2017 in Wiley Online Library 
500 |a Gesehen am 21.07.2020 
520 |a The necessity of orthopedic implant removal is under intense discussion and even if it is performed as an elective procedure, the risk of complications is present. Aim of the study was to identify parameters responsible for an increased risk of early post-operative complications after elective aseptic orthopedic implant removal. We reviewed 1,545 cases of aseptic and elective orthopedic implant removal between 2009 and 2011. The patient́s demographic data, time and duration of operation, patient́s comorbidities, and presence of complications in the first 4 weeks after implant removal were evaluated. Patients with signs of infection at the time of the surgical procedure were excluded from this study. 579 women and 966 men who underwent elective aseptic orthopedic implant removal were identified. Mean age at implant removal was 42 years and mean duration of the surgical procedure was 37 min. In this cohort, 70 patients (4.5%) underwent elective aseptic implant removal after 6pm. 52 patients (3.37%) operated on during daytime suffered from complications post-operatively and five patients (0.3%) who were operated on during the night experienced complications. The parameters age, sex, BMI, and surgeon showed no statistically significant differences for the risk of post-operative complications. Patients’ comorbidities such as diabetes seem to have influence but were not statistically significant either. Patients with revision surgery since their first operation, nocturnal surgery and longer duration of the procedure showed a statistically significant higher risk for complications, especially in the lower leg. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1035-1039, 2018. 
534 |c 2017 
650 4 |a complications 
650 4 |a elective orthopedic implant removal 
650 4 |a metal removal 
700 1 |a Heilgeist, Eva  |d 1985-  |e VerfasserIn  |0 (DE-588)1116637111  |0 (DE-627)870595512  |0 (DE-576)478546890  |4 aut 
700 1 |a Tinelli, Marco  |d 1972-  |e VerfasserIn  |0 (DE-588)129932566  |0 (DE-627)484459643  |0 (DE-576)29790907X  |4 aut 
700 1 |a Bischel, Oliver E.  |e VerfasserIn  |0 (DE-588)1161192166  |0 (DE-627)1024607089  |0 (DE-576)185646328  |4 aut 
773 0 8 |i Enthalten in  |t Journal of orthopaedic research  |d Hoboken, NJ [u.a.] : Wiley, 1983  |g 36(2018), 3, Seite 1035-1039  |h Online-Ressource  |w (DE-627)331018926  |w (DE-600)2050452-4  |w (DE-576)09670439X  |x 1554-527X  |7 nnas  |a High early post-operative complication rate after elective aseptic orthopedic implant removal of upper and lower limb 
773 1 8 |g volume:36  |g year:2018  |g number:3  |g pages:1035-1039  |g extent:5  |a High early post-operative complication rate after elective aseptic orthopedic implant removal of upper and lower limb 
856 4 0 |u http://dx.doi.org/10.1002/jor.23718  |x Verlag  |x Resolving-System  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/jor.23718  |x Verlag  |3 Volltext 
951 |a AR 
992 |a 20180614 
993 |a Article 
994 |a 2018 
998 |g 1161192166  |a Bischel, Oliver E.  |m 1161192166:Bischel, Oliver E.  |d 50000  |e 50000PB1161192166  |k 0/50000/  |p 4  |y j 
998 |g 129932566  |a Tinelli, Marco  |m 129932566:Tinelli, Marco  |d 50000  |e 50000PT129932566  |k 0/50000/  |p 3 
998 |g 1075748429  |a Höppchen, Arnold  |m 1075748429:Höppchen, Arnold  |d 60000  |d 62400  |e 60000PH1075748429  |e 62400PH1075748429  |k 0/60000/  |k 1/60000/62400/  |p 1  |x j 
999 |a KXP-PPN157637761X  |e 3012693866 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"display":"Höppchen, Arnold","roleDisplay":"VerfasserIn","role":"aut","family":"Höppchen","given":"Arnold"},{"family":"Heilgeist","given":"Eva","roleDisplay":"VerfasserIn","display":"Heilgeist, Eva","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Tinelli, Marco","given":"Marco","family":"Tinelli"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Bischel, Oliver E.","given":"Oliver E.","family":"Bischel"}],"title":[{"title":"High early post-operative complication rate after elective aseptic orthopedic implant removal of upper and lower limb","title_sort":"High early post-operative complication rate after elective aseptic orthopedic implant removal of upper and lower limb"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Published online 1 September 2017 in Wiley Online Library","Gesehen am 21.07.2020"],"language":["eng"],"recId":"157637761X","name":{"displayForm":["Arnold J. Suda, Eva Heilgeist, Marco Tinelli, Oliver E. Bischel"]},"origin":[{"dateIssuedKey":"2018","dateIssuedDisp":"2018"}],"id":{"doi":["10.1002/jor.23718"],"eki":["157637761X"]},"physDesc":[{"extent":"5 S."}],"relHost":[{"title":[{"subtitle":"a journal of musculoskeletal investigations ; official publication of the Orthopaedic Research Society","title":"Journal of orthopaedic research","title_sort":"Journal of orthopaedic research"}],"origin":[{"dateIssuedDisp":"1983-","publisher":"Wiley ; Elsevier Science","dateIssuedKey":"1983","publisherPlace":"Hoboken, NJ [u.a.] ; Amsterdam [u.a.]"}],"id":{"issn":["1554-527X"],"doi":["10.1002/(ISSN)1554-527X"],"eki":["331018926"],"zdb":["2050452-4"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"High early post-operative complication rate after elective aseptic orthopedic implant removal of upper and lower limbJournal of orthopaedic research","physDesc":[{"extent":"Online-Ressource"}],"recId":"331018926","language":["eng"],"pubHistory":["1.1983 -"],"part":{"extent":"5","text":"36(2018), 3, Seite 1035-1039","volume":"36","issue":"3","pages":"1035-1039","year":"2018"}}]} 
SRT |a HOEPPCHENAHIGHEARLYP2018