Free-breathing sparse sampling cine MR imaging with iterative reconstruction for the assessment of left ventricular function and mass at 3.0 T

PurposeTo prospectively evaluate the accuracy of left ventricle (LV) analysis with a two-dimensional real-time cine true fast imaging with steady-state precession (trueFISP) magnetic resonance (MR) imaging sequence featuring sparse data sampling with iterative reconstruction (SSIR) performed with an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Janssen, Sonja (VerfasserIn) , Henzler, Thomas (VerfasserIn) , Haubenreisser, Holger (VerfasserIn) , Dösch, Christina (VerfasserIn) , Borggrefe, Martin (VerfasserIn) , Schönberg, Stefan (VerfasserIn) , Papavassiliu, Theano (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 2017
In: Radiology
Year: 2016, Jahrgang: 282, Heft: 1, Pages: 74-83
ISSN:1527-1315
DOI:10.1148/radiol.2016151002
Online-Zugang:Verlag, LF, Volltext: http://dx.doi.org/10.1148/radiol.2016151002
Verlag, LF, Volltext: https://pubs.rsna.org/doi/10.1148/radiol.2016151002
Volltext
Verfasserangaben:Sonja Sudarski, MD, Thomas Henzler, MD, Holger Haubenreisser, MD, Christina Dösch, MD, Michael O. Zenge, PhD, Michaela Schmidt, RT, Mariappan S. Nadar, PhD, Martin Borggrefe, MD, Stefan O. Schoenberg, MD, Theano Papavassiliu, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1576378942
003 DE-627
005 20240314104342.0
007 cr uuu---uuuuu
008 180614r20172016xx |||||o 00| ||eng c
024 7 |a 10.1148/radiol.2016151002  |2 doi 
035 |a (DE-627)1576378942 
035 |a (DE-576)506378942 
035 |a (DE-599)BSZ506378942 
035 |a (OCoLC)1341011595 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Janssen, Sonja  |d 1987-  |e VerfasserIn  |0 (DE-588)1033103748  |0 (DE-627)74078871X  |0 (DE-576)380756110  |4 aut 
245 1 0 |a Free-breathing sparse sampling cine MR imaging with iterative reconstruction for the assessment of left ventricular function and mass at 3.0 T  |c Sonja Sudarski, MD, Thomas Henzler, MD, Holger Haubenreisser, MD, Christina Dösch, MD, Michael O. Zenge, PhD, Michaela Schmidt, RT, Mariappan S. Nadar, PhD, Martin Borggrefe, MD, Stefan O. Schoenberg, MD, Theano Papavassiliu, MD 
264 1 |c 2017 
300 |a 10 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Published online: Jul 11 2016 
500 |a Gesehen am 14.06.2018 
520 |a PurposeTo prospectively evaluate the accuracy of left ventricle (LV) analysis with a two-dimensional real-time cine true fast imaging with steady-state precession (trueFISP) magnetic resonance (MR) imaging sequence featuring sparse data sampling with iterative reconstruction (SSIR) performed with and without breath-hold (BH) commands at 3.0 T.Materials and MethodsTen control subjects (mean age, 35 years; range, 25-56 years) and 60 patients scheduled to undergo a routine cardiac examination that included LV analysis (mean age, 58 years; range, 20-86 years) underwent a fully sampled segmented multiple BH cine sequence (standard of reference) and a prototype undersampled SSIR sequence performed during a single BH and during free breathing (non-BH imaging). Quantitative analysis of LV function and mass was performed. Linear regression, Bland-Altman analysis, and paired t testing were performed.ResultsSimilar to the results in control subjects, analysis of the 60 patients showed excellent correlation with the standard of reference for single-BH SSIR (r = 0.93-0.99) and non-BH SSIR (r = 0.92-0.98) for LV ejection fraction (EF), volume, and mass (P < .0001 for all). Irrespective of breath holding, LV end-diastolic mass was overestimated with SSIR (standard of reference: 163.9 g ± 58.9, single-BH SSIR: 178.5 g ± 62.0 [P < .0001], non-BH SSIR: 175.3 g ± 63.7 [P < .0001]); the other parameters were not significantly different (EF: 49.3% ± 11.9 with standard of reference, 48.8% ± 11.8 with single-BH SSIR, 48.8% ± 11 with non-BH SSIR; P = .03 and P = .12, respectively). Bland-Altman analysis showed similar measurement errors for single-BH SSIR and non-BH SSIR when compared with standard of reference measurements for EF, volume, and mass.ConclusionAssessment of LV function with SSIR at 3.0 T is noninferior to the standard of reference irrespective of BH commands. LV mass, however, is overestimated with SSIR.© RSNA, 2016Online supplemental material is available for this article. 
534 |c 2016 
700 1 |a Henzler, Thomas  |d 1980-  |e VerfasserIn  |0 (DE-588)134001486  |0 (DE-627)559468415  |0 (DE-576)276829948  |4 aut 
700 1 |a Haubenreisser, Holger  |d 1985-  |e VerfasserIn  |0 (DE-588)1050055322  |0 (DE-627)783257791  |0 (DE-576)404356281  |4 aut 
700 1 |a Dösch, Christina  |d 1979-  |e VerfasserIn  |0 (DE-588)132004100  |0 (DE-627)516483846  |0 (DE-576)298887207  |4 aut 
700 1 |a Borggrefe, Martin  |e VerfasserIn  |0 (DE-588)1025920546  |0 (DE-627)725574232  |0 (DE-576)370913426  |4 aut 
700 1 |a Schönberg, Stefan  |d 1969-  |e VerfasserIn  |0 (DE-588)131557912  |0 (DE-627)510700624  |0 (DE-576)298584891  |4 aut 
700 1 |a Papavassiliu, Theano  |d 1970-  |e VerfasserIn  |0 (DE-588)1028853440  |0 (DE-627)731667417  |0 (DE-576)376292849  |4 aut 
773 0 8 |i Enthalten in  |t Radiology  |d Oak Brook, Ill. : Soc., 1923  |g 282(2017), 1, Seite 74-83  |h Online-Ressource  |w (DE-627)320487253  |w (DE-600)2010588-5  |w (DE-576)094056706  |x 1527-1315  |7 nnas  |a Free-breathing sparse sampling cine MR imaging with iterative reconstruction for the assessment of left ventricular function and mass at 3.0 T 
773 1 8 |g volume:282  |g year:2017  |g number:1  |g pages:74-83  |g extent:10  |a Free-breathing sparse sampling cine MR imaging with iterative reconstruction for the assessment of left ventricular function and mass at 3.0 T 
856 4 0 |u http://dx.doi.org/10.1148/radiol.2016151002  |x Verlag  |x Resolving-System  |y LF  |3 Volltext 
856 4 0 |u https://pubs.rsna.org/doi/10.1148/radiol.2016151002  |x Verlag  |y LF  |3 Volltext 
951 |a AR 
992 |a 20180614 
993 |a Article 
994 |a 2017 
998 |g 1028853440  |a Papavassiliu, Theano  |m 1028853440:Papavassiliu, Theano  |d 60000  |e 60000PP1028853440  |k 0/60000/  |p 10  |y j 
998 |g 131557912  |a Schönberg, Stefan  |m 131557912:Schönberg, Stefan  |d 60000  |d 62900  |e 60000PS131557912  |e 62900PS131557912  |k 0/60000/  |k 1/60000/62900/  |p 9 
998 |g 1025920546  |a Borggrefe, Martin  |m 1025920546:Borggrefe, Martin  |d 60000  |d 61000  |e 60000PB1025920546  |e 61000PB1025920546  |k 0/60000/  |k 1/60000/61000/  |p 8 
998 |g 132004100  |a Dösch, Christina  |m 132004100:Dösch, Christina  |d 60000  |d 61000  |e 60000PD132004100  |e 61000PD132004100  |k 0/60000/  |k 1/60000/61000/  |p 4 
998 |g 1050055322  |a Haubenreisser, Holger  |m 1050055322:Haubenreisser, Holger  |d 60000  |d 62900  |e 60000PH1050055322  |e 62900PH1050055322  |k 0/60000/  |k 1/60000/62900/  |p 3 
998 |g 134001486  |a Henzler, Thomas  |m 134001486:Henzler, Thomas  |d 60000  |e 60000PH134001486  |k 0/60000/  |p 2 
998 |g 1033103748  |a Janssen, Sonja  |m 1033103748:Janssen, Sonja  |d 60000  |d 62900  |e 60000PJ1033103748  |e 62900PJ1033103748  |k 0/60000/  |k 1/60000/62900/  |p 1  |x j 
999 |a KXP-PPN1576378942  |e 3012695346 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"title":[{"title_sort":"Free-breathing sparse sampling cine MR imaging with iterative reconstruction for the assessment of left ventricular function and mass at 3.0 T","title":"Free-breathing sparse sampling cine MR imaging with iterative reconstruction for the assessment of left ventricular function and mass at 3.0 T"}],"person":[{"role":"aut","family":"Janssen","display":"Janssen, Sonja","given":"Sonja"},{"role":"aut","family":"Henzler","display":"Henzler, Thomas","given":"Thomas"},{"given":"Holger","display":"Haubenreisser, Holger","family":"Haubenreisser","role":"aut"},{"given":"Christina","display":"Dösch, Christina","family":"Dösch","role":"aut"},{"role":"aut","family":"Borggrefe","given":"Martin","display":"Borggrefe, Martin"},{"role":"aut","family":"Schönberg","display":"Schönberg, Stefan","given":"Stefan"},{"given":"Theano","display":"Papavassiliu, Theano","family":"Papavassiliu","role":"aut"}],"recId":"1576378942","name":{"displayForm":["Sonja Sudarski, MD, Thomas Henzler, MD, Holger Haubenreisser, MD, Christina Dösch, MD, Michael O. Zenge, PhD, Michaela Schmidt, RT, Mariappan S. Nadar, PhD, Martin Borggrefe, MD, Stefan O. Schoenberg, MD, Theano Papavassiliu, MD"]},"origin":[{"dateIssuedKey":"2017","dateIssuedDisp":"2017"}],"relHost":[{"corporate":[{"display":"Radiological Society of North America","role":"isb"}],"origin":[{"dateIssuedDisp":"1923-","publisher":"Soc.","publisherPlace":"Oak Brook, Ill.","dateIssuedKey":"1923"}],"name":{"displayForm":["The Radiological Society of North America"]},"title":[{"title_sort":"Radiology","title":"Radiology"}],"part":{"extent":"10","issue":"1","text":"282(2017), 1, Seite 74-83","volume":"282","year":"2017","pages":"74-83"},"id":{"eki":["320487253"],"issn":["1527-1315"],"zdb":["2010588-5"]},"physDesc":[{"extent":"Online-Ressource"}],"note":["Fortsetzung der Druck-Ausgabe","Gesehen 07.11.22"],"disp":"Free-breathing sparse sampling cine MR imaging with iterative reconstruction for the assessment of left ventricular function and mass at 3.0 TRadiology","recId":"320487253","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1923 -"]}],"note":["Published online: Jul 11 2016","Gesehen am 14.06.2018"],"physDesc":[{"extent":"10 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["1576378942"],"doi":["10.1148/radiol.2016151002"]}} 
SRT |a JANSSENSONFREEBREATH2017